A novel approach to bar adsorptive microextraction: Cork as extractor phase for determination of benzophenone, triclocarban and parabens in aqueous samples

被引:56
作者
Dias, Adriana Neves [1 ]
da Silva, Ana Cristine [1 ]
Simao, Vanessa [1 ]
Merib, Josias [1 ]
Carasek, Eduardo [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
Bar adsorptive microextraction; Cork bar; Parabens; Benzophenone; Triclocarban; Water samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; ENVIRONMENTAL WATER MATRICES; SELECTIVE SORBENT PHASES; PERSONAL CARE PRODUCTS; TRACE-LEVEL ANALYSIS; GAS-CHROMATOGRAPHY; MICRO-EXTRACTION; REAL MATRICES; MU-E;
D O I
10.1016/j.aca.2015.07.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study describes the use of cork as a new coating for bar adsorptive microextraction (BA mu E) and its application in determining benzophenone, triclocarban and parabens in aqueous samples by HPLC-DAD. In this study bars with 7.5 and 15 mm of length were used. The extraction and liquid desorption steps for BAmE were optimized employing multivariate and univariate procedures. The desorption time and solvent used for liquid desorption were optimized by univariate and multivariate studies, respectively. For the extraction step the sample pH was optimized by univariate experiments while the parameters extraction time and ionic strength were evaluated using the Doehlert design. The optimum extraction conditions were sample pH 5.5, NaCl concentration 25% and extraction time 90 min. Liquid desorption was carried out for 30 min with 250 mu L (bar length of 15 mm) or 100 mu L (bar length of 7.5 mm) of ACN:MeOH (50: 50, v/v). The quantification limits varied between 1.6 and 20 mu g L-1 (bar length of 15 mm) and 0.64 and 8 mu g L-1 (bar length of 7.5 mm). The linear correlation coefficients were higher than 0.98 for both bars. The method with 7.5 mm bar length showed recovery values between 65 and 123%. The bar-to-bar reproducibility and the repeatability were lower than 13% (n = 2) and 14% (n = 3), respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 35 条
[1]   Application of bar adsorptive microextraction (BAμE) for anti-doping control screening of anabolic steroids in urine matrices [J].
Ahmad, S. M. ;
Almeida, C. ;
Neng, N. R. ;
Nogueira, J. M. F. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 969 :35-41
[2]   Determination of steroid sex hormones in real matrices by bar adsorptive microextraction (BAμE) [J].
Almeida, C. ;
Nogueira, J. M. F. .
TALANTA, 2015, 136 :145-154
[3]   Determination of trace levels of parabens in real matrices by bar adsorptive microextraction using selective sorbent phases [J].
Almeida, C. ;
Nogueira, J. M. F. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1348 :17-26
[4]   Improvements on bar adsorptive microextraction (BAμE) technique-Application for the determination of insecticide repellents in environmental water matrices [J].
Almeida, C. ;
Strzelczyk, Rafal ;
Nogueira, J. M. F. .
TALANTA, 2014, 120 :126-134
[5]   Determination of trace levels of benzophenone-type ultra-violet filters in real matrices by bar adsorptive micro-extraction using selective sorbent phases [J].
Almeida, C. ;
Stepkowska, A. ;
Alegre, A. ;
Nogueira, J. M. F. .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1311 :1-10
[6]   Comparison of the selectivity of different sorbent phases for bar adsorptive microextraction-Application to trace level analysis of fungicides in real matrices [J].
Almeida, C. ;
Nogueira, J. M. F. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1265 :7-16
[7]   A simple solvent collection technique for a dispersive liquid-liquid microextraction of parabens from aqueous samples using low-density organic solvent [J].
Cabuk, Hasan ;
Akyuz, Mehmet ;
Ata, Sevket .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (19) :2645-2652
[8]   Determination of parabens and triclosan in indoor dust using matrix solid-phase dispersion and gas chromatography with tandem mass spectrometry [J].
Canosa, P. ;
Rodriguez, I. ;
Rubi, E. ;
Cela, R. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1675-1681
[9]   New sorbent in the dispersive solid phase extraction step of quick, easy, cheap, effective, rugged, and safe for the extraction of organic contaminants in drinking water treatment sludge [J].
Cerqueira, Maristela B. R. ;
Caldas, Sergiane S. ;
Primel, Ednei G. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1336 :10-22
[10]   Determination of biocides in different environmental matrices by use of ultra-high-performance liquid chromatography-tandem mass spectrometry [J].
Chen, Zhi-Feng ;
Ying, Guang-Guo ;
Lai, Hua-Jie ;
Chen, Feng ;
Su, Hao-Chang ;
Liu, You-Sheng ;
Peng, Fu-Qiang ;
Zhao, Jian-Liang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (10) :3175-3188