The depth of anaesthesia associated with the administration of isoflurane 2.5% during cardiopulmonary bypass

被引:8
作者
Alston, R. Peter [1 ]
Connelly, Michael [2 ,3 ]
MacKenzie, Christopher [4 ]
Just, George [5 ]
Homer, Natalie [5 ]
机构
[1] Royal Infirm Edinburgh NHS Trust, Dept Anaesthesia Crit Care & Pain Med, 51 Little France Crescent, Edinburgh EH16 4SA, Midlothian, Scotland
[2] Univ Edinburgh, Sch Med & Vet Med, Edinburgh, Midlothian, Scotland
[3] North Bristol NHS Trust, Southmead Hosp, Intens Care Unit, Bristol, Avon, England
[4] Univ Edinburgh, Sch Med & Vet Med, Dept Anaesthesia & Crit Care, Edinburgh, Midlothian, Scotland
[5] Univ Edinburgh, Mass Spectrometry Core, Edinburgh Clin Res Facil, Queens Med Res Inst, Edinburgh, Midlothian, Scotland
来源
PERFUSION-UK | 2019年 / 34卷 / 05期
关键词
cardiopulmonary bypass; oxygenator; isoflurane; consciousness monitors; anaesthesia; BISPECTRAL INDEX; GENERAL-ANESTHESIA; ARTERIAL-BLOOD; SEVOFLURANE; SURGERY; OXYGENATOR; SOLUBILITY; DESFLURANE; TEMPERATURE; HYPOTHERMIA;
D O I
10.1177/0267659118822946
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Administering isoflurane 2.5% into the oxygenator during cardiopulmonary bypass results in no patient movement. However, doing so may result in an excessive depth of anaesthesia particularly, when hypothermia is induced. Bispectral index and arterial blood and oxygenator exhaust concentrations of volatile anaesthetics should be related to depth of anaesthesia. The primary aim of this study was to measure the depth of anaesthesia using bispectral index, resulting from administering isoflurane 2.5% into the oxygenator during cardiopulmonary bypass, and secondary aims were to examine the relationships between blood and oxygenator exhaust isoflurane concentrations and bispectral index. Methods: Arterial and mixed-venous blood samples were aspirated at three time points during cardiopulmonary bypass and measured for isoflurane concentration using mass spectrometry. Simultaneously, oxygenator exhaust isoflurane concentration, nasopharyngeal temperature and bispectral index were recorded. Results: When averaged across the three time points, all patients had a bispectral index score below 40 (binomial test, p < 0.001). There were no significant correlations between bispectral index score and arterial or mixed-venous blood isoflurane concentrations (r = -0.082, p = 0.715; r = -0.036, p = 0.874) and oxygenator exhaust gas concentration of isoflurane (r = -0.369, p = 0.091). Conclusion: When 2.5% isoflurane was administered into the sweep gas supply to the oxygenator during cardiopulmonary bypass, all patients experienced a bispectral index score less than 40 and no significant relationship was found between either arterial or mixed-venous blood or oxygenator exhaust concentrations of isoflurane and bispectral index.
引用
收藏
页码:392 / 398
页数:7
相关论文
共 33 条
[1]  
Alston R P, 1992, J Cardiothorac Vasc Anesth, V6, P700, DOI 10.1016/1053-0770(92)90055-C
[2]   Anesthetic Management During Cardiopulmonary Bypass: A Systematic Review [J].
Barry, Aaron E. ;
Chaney, Mark A. ;
London, Martin J. .
ANESTHESIA AND ANALGESIA, 2015, 120 (04) :749-769
[3]   A POWER PRIMER [J].
COHEN, J .
PSYCHOLOGICAL BULLETIN, 1992, 112 (01) :155-159
[4]   THE DEPTH OF ANAESTHESIA ASSOCIATED WITH ADMINISTERING 2.5% ISOFLURANE DURING CARDIOPULMONARY BYPASS [J].
Connelly, M. ;
Alston, R. P. ;
Just, G. ;
McKenzie, C. .
ANESTHESIA AND ANALGESIA, 2016, 123 :535-535
[5]   Effects of desflurane and sevoflurane on length-dependent regulation of myocardial function in coronary surgery patients [J].
De Hert, SG ;
Van der Linden, PJ ;
ten Broecke, PW ;
Vermeylen, KT ;
Rodrigus, IE ;
Stockman, BA .
ANESTHESIOLOGY, 2001, 95 (02) :357-363
[6]   Effects of cardiopulmonary bypass and hypothermia on electroencephalographic variables [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
ANAESTHESIA, 1997, 52 (11) :1048-1055
[7]   Principles of anaesthetic vaporizers [J].
Eales, Mike ;
Cooper, Robin .
ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2007, 8 (03) :111-115
[8]  
EGER RR, 1985, ANESTH ANALG, V64, P640
[9]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[10]   In vitro uptake and elimination of isoflurane by different membrane oxygenators [J].
Hickey, S ;
Gaylor, JDS ;
Kenny, GNC .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (03) :352-355