Soft tissue reactions evoked by implanted gallium phosphide

被引:28
作者
Linsmeier, Cecilia E. [1 ]
Wallman, Lars [1 ,3 ]
Faxius, Linda [2 ]
Schouenborg, Jens [1 ]
Bjursten, Lars M. [2 ]
Danielsen, Nils [1 ]
机构
[1] Lund Univ, Neuronano Res Ctr, SE-22184 Lund, Sweden
[2] Lund Univ, Dept Clin Sci, SE-20502 Malmo, Sweden
[3] Lund Univ, Dept Elect Measurements, SE-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
GaP; Foreign-body response; In vivo test; Soft tissue; Immunohistochemistry; Nanowires;
D O I
10.1016/j.biomaterials.2008.08.028
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Neural devices may play an important role in the diagnosis and therapy of several clinical conditions, such as stroke, trauma or neurodegenerative disorders, by facilitating motor and pain control. Such interfaces, chronically implanted in the CNS, need to be biocompatible and have the ability to stimulate and record nerve signals. However, neural devices of today are not fully optimized. Nanostructured surfaces may improve electrical properties and lower evoked tissue responses. Vertical gallium phosphide (GaP) nanowires epitaxially grown from a GaP surface is one way of creating nanostructured electrodes. Thus, we chose to study the soft tissue reactions evoked by GaP surfaces. GaP and the control material titanium (Ti) were implanted in the rat abdominal wall for evaluation of tissue reactions after 1, 6, or 12 weeks. The foreign-body response was evaluated by measuring the reactive capsule thickness and by quantification of ED1-positive macrophages and total cells in the capsule. Furthermore, the concentration of Ga was measured in blood, brain, liver and kidneys. Statistically significant differences were noticed between GaP and Ti at 12 weeks for total and ED1-positive cell densities in the capsule. The chemical analysis showed that the concentration of Ga in brain, liver and kidneys increased during 12 weeks of implantation, indicating loss of Ga from the implant. Taken together, our results show that the biocompatible properties of GaP are worse than those of the well-documented biomaterial Ti. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4598 / 4604
页数:7
相关论文
共 28 条
  • [1] DISSIMILAR ALUMINUM AND GALLIUM PERMEATION OF THE BLOOD-BRAIN-BARRIER DEMONSTRATED BY INVIVO MICRODIALYSIS
    ALLEN, DD
    YOKEL, RA
    [J]. JOURNAL OF NEUROCHEMISTRY, 1992, 58 (03) : 903 - 908
  • [2] Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
    Biran, R
    Martin, DC
    Tresco, PA
    [J]. EXPERIMENTAL NEUROLOGY, 2005, 195 (01) : 115 - 126
  • [3] The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull
    Biran, Roy
    Martin, Dave C.
    Tresco, Patrick A.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) : 169 - 178
  • [4] Gallium phosphide nanowires as a substrate for cultured neurons
    Hallstrom, Waldemar
    Martensson, Thomas
    Prinz, Christelle
    Gustavsson, Per
    Montelius, Lars
    Samuelson, Lars
    Kanje, Martin
    [J]. NANO LETTERS, 2007, 7 (10) : 2960 - 2965
  • [5] Neuronal ensemble control of prosthetic devices by a human with tetraplegia
    Hochberg, Leigh R.
    Serruya, Mijail D.
    Friehs, Gerhard M.
    Mukand, Jon A.
    Saleh, Maryam
    Caplan, Abraham H.
    Branner, Almut
    Chen, David
    Penn, Richard D.
    Donoghue, John P.
    [J]. NATURE, 2006, 442 (7099) : 164 - 171
  • [6] ELECTRON-MICROSCOPIC OBSERVATIONS ON THE SOFT-TISSUE AROUND CLINICAL LONG-TERM PERCUTANEOUS TITANIUM IMPLANTS
    HOLGERS, KM
    THOMSEN, P
    TJELLSTROM, A
    ERICSON, LE
    [J]. BIOMATERIALS, 1995, 16 (02) : 83 - 90
  • [7] Electrical properties of individual single-crystalline gallium phosphide nanowires with an outer oxide shell
    Kim, JR
    Kim, BK
    Lee, JO
    Kim, J
    Seo, HJ
    Lee, CJ
    Kim, JJ
    [J]. NANOTECHNOLOGY, 2004, 15 (11) : 1397 - 1400
  • [8] KIPKE DR, 2004, P IEEE ENG MED BIOL, V7, P5344
  • [9] The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfaces
    Maynard, EM
    Nordhausen, CT
    Normann, RA
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (03): : 228 - 239
  • [10] Chronic, multisite, multielectrode recordings in macaque monkeys
    Nicolelis, MAL
    Dimitrov, D
    Carmena, JM
    Crist, R
    Lehew, G
    Kralik, JD
    Wise, SP
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (19) : 11041 - 11046