THE INFLUENCE OF ENVIRONMENTAL FACTORS ON THE DEPOSITION VELOCITY OF THORON PROGENY

被引:8
作者
Li, H. [1 ]
Zhang, L. [2 ]
Guo, Q. [1 ]
机构
[1] Peking Univ, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[2] Solid Dosimetr Detector & Method Lab, Beijing 102205, Peoples R China
基金
中国国家自然科学基金;
关键词
RADON; EXPOSURES; SURFACES; RATES; DTPS;
D O I
10.1093/rpd/ncs194
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Passive measuring devices are comprehensively employed in thoron progeny surveys, while the deposition velocity of thoron progeny is the most critical parameter, which varies in different environments. In this study, to analyse the influence of environmental factors on thoron progeny deposition velocity, an improved model was proposed on the basis of Lai's aerosol deposition model and the Jacobi's model, and a series of measurements were carried out to verify the model. According to the calculations, deposition velocity decreases with increasing aerosol diameter and also aerosol concentration, while increases with increasing ventilation rate. In typical indoor environments, a typical value of 1.26 x 10(-5)m s(-1) is recommended, with a range between 7.6 x 10(-7) and 3.2 x 10(-4) m s(-1).
引用
收藏
页码:84 / 88
页数:5
相关论文
共 23 条
[1]  
[毕垒 BI Lei], 2009, [原子能科学技术, Atomic Energy Science and Technology], V43, P461
[2]   Characteristics of thoron and thoron progeny in Canadian homes [J].
Chen, Jing ;
Moir, Deborah ;
Sorimachi, Atsuyuki ;
Tokonami, Shinji .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2011, 50 (01) :85-89
[3]  
DOI M, 1994, HEALTH PHYS, V66, P274, DOI 10.1097/00004032-199403000-00007
[4]   Deposition rates on smooth surfaces and coagulation of aerosol particles inside a test chamber [J].
Hussein, Tareq ;
Hruska, Ales ;
Dohanyosova, Pavla ;
Dzumbova, Lucie ;
Hemerka, Jiri ;
Kulmala, Markku ;
Smolik, Jiri .
ATMOSPHERIC ENVIRONMENT, 2009, 43 (04) :905-914
[5]   ACTIVITY AND POTENTIAL ALPHA-ENERGY OF RADON-222-DAUGHTERS AND RADON-220-DAUGHTERS IN DIFFERENT AIR ATMOSPHERES [J].
JACOBI, W .
HEALTH PHYSICS, 1972, 22 (05) :441-+
[6]  
Lai ACK, 2000, J AEROSOL SCI, V31, P463
[7]   An overview of thoron and its progeny in the indoor environment [J].
McLaughlin, J. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :316-321
[8]   An integrated approach for the assessment of the thoron progeny exposures using direct thoron progeny sensors [J].
Mishra, R. ;
Prajith, R. ;
Sapra, B. K. ;
Mayya, Y. S. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :363-366
[9]   Study of a deposition-based direct thoron progeny sensor (DTPS) technique for estimating equilibrium equivalent thoron concentration (EETC) in indoor environment [J].
Mishra, Rosaline ;
Mayya, Y. S. .
RADIATION MEASUREMENTS, 2008, 43 (08) :1408-1416
[10]   Response of direct thoron progeny sensors (DTPS) to various aerosol concentrations and ventilation rates [J].
Mishra, Rosaline ;
Prajith, R. ;
Sapra, B. K. ;
Mayya, Y. S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (06) :671-675