Simultaneous estimation of metformin hydrochloride, pioglitazone hydrochloride, and glimepiride by RP-HPLC in tablet formulation

被引:55
作者
Jain, Deepti [1 ]
Jain, Surendra
Jain, Deepak [1 ]
Amin, Maulik [1 ]
机构
[1] Rajiv Gandhi Tech Univ, Sch Pharmaceut Sci, Bhopal, Madhya Pradesh, India
关键词
D O I
10.1093/chromsci/46.6.501
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, precise, rapid, and reproducible reversed-phase high-performance liquid chromatography method is developed for the simultaneous estimation of metformin hydrochloride (MET), pioglitazone hydrochloride (PIO), and glimepiride (GLP) present in multicomponent dosage forms. Chromatography is carried out isocratically at 25°C ± 0.5°C on an Inertsil-ODS-3 (C-18) Column (250 × 4.60 mm, 5 μm) with a mobile phase composed of methanol-phosphate buffer (pH 4.3) in the ratio of 75:25 v/v at a flow rate of 1 mL/min. Detection is carried out using a UV-PDA detector at 258 nm. Parameters such as linearity, precision, accuracy, recovery, specificity, and ruggedness are studied as reported in the International Conference on Harmonization guidelines. The retention times for MET, PIO, and GLP are 2.66 + 0.5 min, 7.12 + 0.5 min, and 10.17 + 0.5 min, respectively. The linearity range and percentage recoveries for MET, PIO, and GLP are 10-5000, 10-150, and 1-10 μg/mL and 100.4%, 100.06%, and 100.2%, respectively. The correlation coefficients for all components are close to 1. The relative standard deviations for three replicate measurements in three concentrations of samples in tablets are always less than 2%.
引用
收藏
页码:501 / 504
页数:4
相关论文
共 13 条
  • [1] Analysis of glimepiride by using derivative UV spectrophotometric method
    Altinöz, S
    Tekeli, D
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (03) : 507 - 515
  • [2] Hohyun K., 2004, CHROMATOGRAPHIA, V60, P93
  • [3] John-Lin Z, 2003, J PHARM BIOMED ANAL, V33, P101
  • [4] KAH HY, 1998, J CHROMATOGR B, V710, P243
  • [5] LC determination of glimepiride and its related impurities
    Khan, MA
    Sinha, S
    Vartak, S
    Bhartiya, A
    Kumar, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (05) : 928 - 943
  • [6] Kolte BL, 2004, J CHROMATOGR SCI, V42, P27
  • [7] Simultaneous determination of pioglitazone and glimepiride by high-performance liquid chromatography
    Sane, RT
    Menon, SN
    Inamdar, S
    Mote, M
    Gundi, G
    [J]. CHROMATOGRAPHIA, 2004, 59 (7-8) : 451 - 453
  • [8] High-performance liquid chromatographic method for the determination of pioglitazone in human plasma using ultraviolet detection and its application to a pharmacokinetic study
    Sripalakit, Pattana
    Neamhom, Penporn
    Saraphanchotiwitthaya, Aurasorn
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 843 (02): : 164 - 169
  • [9] SWEETMAN SC, 2002, MARTINDALE COMPLETE, P322
  • [10] SWEETMANN SC, 2002, MARTINDAL COMPLETE D, P332