Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

被引:129
|
作者
Leonhardt, Steffen [1 ]
Lachmann, Burkhard [2 ]
机构
[1] Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Helmholtz Inst, Aachen, Germany
[2] Charite Campus Virchow Klinikum CVK, Dept Anaesthesiol, Berlin, Germany
关键词
Electrical impedance tomography; EIT; Regional ventilation monitoring; Regional perfusion monitoring; END-EXPIRATORY-PRESSURE; RESPIRATORY-DISTRESS-SYNDROME; REGIONAL LUNG-VOLUME; FREQUENCY OSCILLATORY VENTILATION; PULMONARY PERFUSION; ENDOTRACHEAL SUCTION; ALVEOLAR VENTILATION; COMPUTED-TOMOGRAPHY; EXPERIMENTAL-MODEL; TIDAL VENTILATION;
D O I
10.1007/s00134-012-2684-z
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
This review summarizes the state-of-the-art in electrical impedance tomography (EIT) for ventilation and perfusion imaging. EIT is a relatively new technology used to image regional impedance distributions in a cross-sectional area of the body. After the introduction, a brief overview of the recent history is provided followed by a review of the literature on regional ventilation monitoring using EIT. Several recently presented indices that are useful to extract information from EIT image streams are described. Selected experimental and clinical findings are discussed with respect to future routine applications in intensive care. Finally, past and ongoing research activities aimed at obtaining cardiac output and regional perfusion information from EIT image streams are summarized.
引用
收藏
页码:1917 / 1929
页数:13
相关论文
共 50 条
  • [41] Technical Principles and Clinical Applications of Electrical Impedance Tomography in Pulmonary Monitoring
    Cui, Ziqiang
    Liu, Xinyan
    Qu, Hantao
    Wang, Huaxiang
    SENSORS, 2024, 24 (14)
  • [42] Absolute values of regional ventilation-perfusion mismatch in patients with ARDS monitored by electrical impedance tomography and the role of dead space and shunt compensation
    Leali, Marco
    Marongiu, Ines
    Spinelli, Elena
    Chiavieri, Valentina
    Perez, Joaquin
    Panigada, Mauro
    Grasselli, Giacomo
    Mauri, Tommaso
    CRITICAL CARE, 2024, 28 (01)
  • [43] PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography
    Zhao, Zhanqi
    Steinmann, Daniel
    Frerichs, Inez
    Guttmann, Josef
    Moeller, Knut
    CRITICAL CARE, 2010, 14 (01):
  • [44] Electrical impedance tomography in acute lung injury
    Riera, J.
    Riu, P. J.
    Casan, P.
    Masclans, J. R.
    MEDICINA INTENSIVA, 2011, 35 (08) : 509 - 517
  • [45] Monitoring changes in distribution of pulmonary ventilation by functional electrical impedance tomography in anaesthetized ponies
    Auer, Ulrike
    Schramel, J. Peter
    Moens, Yves P.
    Mosing, Martina
    Braun, Christina
    VETERINARY ANAESTHESIA AND ANALGESIA, 2019, 46 (02) : 200 - 208
  • [46] Automatic protective ventilation using the ARDSNet protocol with the additional monitoring of electrical impedance tomography
    Anake Pomprapa
    David Schwaiberger
    Philipp Pickerodt
    Onno Tjarks
    Burkhard Lachmann
    Steffen Leonhardt
    Critical Care, 18
  • [47] Regional ventilation redistribution measured by electrical impedance tomography during spontaneous breathing trial with automatic tube compensation
    Hsu, Yeong-Long
    Tien, Ai-Jia
    Chang, Mei-Yun
    Chang, Hao-Tai
    Moeller, Knut
    Frerichs, Inez
    Zhao, Zhanqi
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (06) : 1193 - 1203
  • [48] Monitoring lungs with electrical impedance tomography
    Bevilacqua, Joyce Da Silva
    Yoshikawaz, Roberto Masaishi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2007, 15 (04) : 325 - 337
  • [49] Prone positioning improves ventilation–perfusion matching assessed by electrical impedance tomography in patients with ARDS: a prospective physiological study
    Yu-xian Wang
    Ming Zhong
    Min-hui Dong
    Jie-qiong Song
    Yi-jun Zheng
    Wei Wu
    Jia-le Tao
    Ling Zhu
    Xin Zheng
    Critical Care, 26
  • [50] Electrical Impedance Tomography for Hemodynamic Monitoring
    Leonhardt, Steffen
    Pikkemaat, Robert
    Stenqvist, Ola
    Lundin, Stefan
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 122 - 125