10-Year Follow-Up Wear Analysis of First-Generation Highly Crosslinked Polyethylene in Primary Total Hip Arthroplasty

被引:24
作者
Snir, Nimrod [1 ]
Kaye, Ian D. [1 ]
Klifto, Christopher S. [1 ]
Hamula, Mathew J. [1 ]
Wolfson, Theodore S. [1 ]
Schwarzkopf, Ran [2 ]
Jaffe, Fredrick F. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed Surg, New York, NY USA
[2] Univ Calif Irvine, Med Ctr, Dept Orthopaed Surg, Orange, CA 92868 USA
关键词
total hip arthroplasty; highly cross linked polyethylene; wear analysis; first generation; 10-year follow-up; MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR COMPONENTS; COBALT-CHROME; FEMORAL-HEAD; OSTEOLYSIS; PENETRATION; HISTORY; CEMENT;
D O I
10.1016/j.arth.2013.07.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our goal was to report a 10-year follow up of linear penetration rates for HCLPE, and to determine whether a difference exists between penetrations measured on pelvis or hip anterior-posterior radiographs. We reviewed 48 total hip arthroplasties where a first-generation HCLPE liner was used. Femoral head penetration was measured on both AP pelvis and hip radiographs. Total wear and wear rate at 10 years were 1.26 mm and 0.122 mm/y, respectively. The rate decreased significantly after the first 2-3 years, plateauing at a wear rate of 0.05 mm/y for the last 5 years. The AP hip total wear and wear rate were 1.38 mm and 0.133 mm/y respectively, while rates were 1.13 mm and 0.109 mm/y respectively for the pelvis radiographs (P < .05). We found a significant difference in measurements of linear penetration when comparing AP pelvis vs. hip radiographs with lower rates recorded using an AP pelvis. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:630 / 633
页数:4
相关论文
共 47 条
[1]  
Bankston A B, 1993, J Arthroplasty, V8, P315
[2]  
Barrack RL, 1997, CLIN ORTHOP RELAT R, P211
[3]   Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[4]   Continued Improved Wear with an Annealed Highly Cross-linked Polyethylene [J].
Capello, William N. ;
D'Antonio, James A. ;
Ramakrishnan, Rama ;
Naughton, Marybeth .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (03) :825-830
[5]   Accuracy and Precision of Two Computer-Assisted Methods of Radiographic Wear Measurement in Total Hip Arthroplasty [J].
Crockarell, John R., Jr. ;
Snearly, Christine M. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (01) :37-40
[6]   Five-year experience with Crossfire® highly cross-linked polyethylene [J].
D'Antonio, JA ;
Manley, MT ;
Capello, WN ;
Bierbaum, BE ;
Ramakrishnan, R ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :143-150
[7]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]   Measurement of polyethylene wear in acetabular components inserted with and without cement - A randomized trial [J].
Devane, PA ;
Robinson, EJ ;
Bourne, RB ;
Rorabeck, CH ;
Nayak, NN ;
Horne, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :682-689
[9]   Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis [J].
Dowd, JE ;
Sychterz, CJ ;
Young, AM ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) :1102-1107
[10]  
Edidin A, 2000, T ORTHOP RES SOC, V25