Modelling and monitoring natural ventilation for conventional kitchens in Taiwan with transoms replaced with porous screens

被引:5
作者
Chiang, CM
Chang, KF
Lee, CY
Chou, PC
机构
[1] Shu Te Univ, Dept Interior Design, Kaohsiung 824, Taiwan
[2] Natl Cheng Kung Univ, Dept Architecture, Tainan, Taiwan
[3] Da Yeh Univ, Dept Mech & Automat Engn, Changhua, Taiwan
关键词
computational fluid dynamics; conventional kitchen; numerical simulation; porous screen; tracer gas techniques; ventilation efficiency;
D O I
10.1177/1420326X06063872
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study analyses the ventilation efficiency and indoor air quality of conventional kitchens in Taiwan, in which the transoms were replaced by screens of various porosities. Numerical simulations and full-scale laboratory experiments were performed to investigate the influence of the porous screens on the temperature fields, flow fields and ventilation rates within the kitchen. The tracer-gas concentration decay method was applied to measure the air exchange rate and the age of the air in the kitchen. Meanwhile, computational fluid dynamics (CFD) analysis was performed to obtain a detailed understanding of the temperature and flow distributions.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 17 条
[1]  
[Anonymous], 1980, SERIES COMPUTATIONAL, DOI [DOI 10.1201/9781482234213, 10.1201/9781482234213]
[2]  
*ASHRAE, 1989, 621989 ASHRAE
[3]  
Broderick CR, 2000, INDOOR BUILT ENVIRON, V9, P317
[4]   Ventilation for people [J].
Brundrett, G .
INDOOR AND BUILT ENVIRONMENT, 2000, 9 (02) :97-101
[5]  
CHEN GY, 2002, INDOOR BUILD ENV, V11, P340
[6]   The influence of an architectural design alternative (transoms) on indoor air environment in conventional kitchens in Taiwan [J].
Chiang, CM ;
Lai, CM ;
Chou, PC ;
Li, YY .
BUILDING AND ENVIRONMENT, 2000, 35 (07) :579-585
[7]  
CHIANG CM, 1998, P ROOMVENT 98 STOCKH, V2, P563
[8]  
Chiang CM, 1994, J HOUSING STUDIES, V2, P107
[9]  
CHIANG CM, 1996, P IND AIR 96 NAG, V3, P735
[10]  
Chow WK, 1998, INDOOR BUILT ENVIRON, V7, P276