Sustainable Data Centers Powered by Renewable Energy

被引:0
作者
Klein, Levente J. [1 ]
Bermudez, Sergio [1 ]
Wehle, Hans-Dieter [2 ]
Barabasi, Stephan [1 ]
Hamann, Hendrik F. [1 ]
机构
[1] IBM TJ Watson Res Ctr, Yorktown Hts, NY 10598 USA
[2] IBM Syst &Technol Grp, D-71032 Boblingen, Germany
来源
2012 28TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM) | 2012年
关键词
Solar energy; air side economizer; energy forecasting; advanced control; IT scaling; data center;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The energy consumption of data centers (DCs) has dramatically increased in recent years, primarily due to the massive computing demands driven by communications, banking, online retail, and entertainment services. In today's data centers, the cooling and infrastructure operations require almost the same energy as the IT operations. The large energy consumption in data centers prompted government agencies, industries, professional organizations, and academic institutions to investigate sustainable growth paths. We discuss such scenarios based on current trends and projections and propose the required innovations to achieve a 10 fold increase in "performance per Watt" of IT operations. We discuss three possible technology components that would improve the operational performance of data centers: (1) integration of renewable energy sources (2) increasing energy efficiency through IT consolidation and workload optimization, and (3) multifunctional sensor networks for better cooling and infrastructure management. We discuss the key requirements and how these technologies can be combined to achieve a sustainable path.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 18 条
[1]  
[Anonymous], 2011, BEST PRACTICES GUIDE
[2]  
[Anonymous], 2012, SunShot Vision Study
[3]  
ASHRAE, 2011, CISC VIS NETW IND GL
[4]  
ASHRAE, 2011, ASHRAE TC 9.9
[5]  
Belady C., 2010, Carbon Usage Effectiveness (CUE): A Green Grid Data Center Sustainability Metric
[6]  
Bohn R., 2010, MUCH INFORM
[7]  
Dirks S., 2009, IBM I BUS VALUE
[8]   Uncovering energy-efficiency opportunities in data centers [J].
Hamann, H. F. ;
van Kessel, T. G. ;
Iyengar, M. ;
Chung, J. -Y. ;
Hirt, W. ;
Schappert, M. A. ;
Claassen, A. ;
Cook, J. M. ;
Min, W. ;
Amemiya, Y. ;
Lopez, V. ;
Lacey, J. A. ;
O'Boyle, M. .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 2009, 53 (03)
[9]   Methods and techniques for measuring and improving data center best practices [J].
Hamann, Hendrik F. ;
Schappert, Michael ;
Iyengar, Madhusudan ;
van Kessel, Theodore ;
Claassen, Alan .
2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, :1146-+
[10]  
Iyengar M., 2010, ELECT COOLING