Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report

被引:1
作者
Takakusagi, Yosuke [1 ]
Takayama, Yoshiki [2 ]
Kusano, Yohsuke [2 ]
Koge, Hiroaki [1 ]
Kano, Kio [1 ]
Shima, Satoshi [1 ]
Tsuchida, Keisuke [1 ]
Mizoguchi, Nobutaka [1 ]
Yoshida, Daisaku [1 ]
Kamada, Tadashi [1 ]
Miyakawa, Shin
Imura, Koh [2 ]
Katoh, Hiroyuki [1 ]
机构
[1] Kanagawa Canc Ctr, Dept Radiat Oncol, Yokohama, Japan
[2] Kanagawa Canc Ctr, Sect Med Phys & Engn, Yokohama, Japan
关键词
Carbon-ion radiotherapy; Bilateral hip prostheses; Prostate cancer; Metal artifact reduction; Acute toxicity; RADIATION-THERAPY; IRRADIATION; PROTON; SYSTEM; IMRT;
D O I
10.1159/000526932
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Carbon-ion radiotherapy (CIRT) for prostate cancer is both safe and efficacious; beam range calculations use relative stopping power ratio, which is derived from computed tomography (CT) values. However, hip prostheses are made of high atomic number materials and show severe artifacts on CT images. Therefore, it is not possible to accurately calculate dose distribution for CIRT in patients with prostate cancer with hip prostheses. Here, we describe the management of a 77-year-old man with prostate cancer who had previously undergone bilateral hip replacement. CIRT, in combination with androgen deprivation therapy, was recommended as definitive treatment for prostate cancer. Planning CT, magnetic resonance (MRI), and CT images with metal artifact reduction (MAR) were acquired for CIRT planning. MRI and MAR images were superimposed on the planning CT to delineate target volume and organs at risk. The radiation treatment plan consisted of a total dose of 51.6 Gy (relative biological effect) to be delivered in 12 fractions over 3 weeks, and the patient was irradiated in the supine and prone positions with a vertical beam, on alternating days. CIRT was completed as scheduled. No adverse events were observed during treatment or at 3 months after treatment initiation. While we show that CIRT may be a treatment option for patients with prostate cancer with bilateral hip prostheses, further studies are needed to evaluate treatment efficacy and late toxicity and to determine how CIRT can be administered to patients with prostate cancer with bilateral hip prostheses.
引用
收藏
页码:894 / 901
页数:8
相关论文
共 19 条
[1]   Evaluation of two commercial CT metal artifact reduction algorithms for use in proton radiotherapy treatment planning in the head and neck area [J].
Andersson, Karin M. ;
Dahlgren, Christina Vallhagen ;
Reizenstein, Johan ;
Cao, Yang ;
Ahnesjoe, Anders ;
Thunberg, Per .
MEDICAL PHYSICS, 2018, 45 (10) :4329-4344
[2]   The use of CT-MR image registration to define target volumes in pelvic radiotherapy in the presence of bilateral hip replacements [J].
Charnley, N ;
Morgan, A ;
Thomas, E ;
Wilson, S ;
Bacon, S ;
Wilson, D ;
Bottomley, D .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (931) :634-636
[3]   Carbon-ion radiation therapy for prostate cancer [J].
Ishikawa, Hitoshi ;
Tsuji, Hiroshi ;
Kamada, Tadashi ;
Akakura, Koichiro ;
Suzuki, Hiroyoshi ;
Shimazaki, Jun ;
Tsujii, Hirohiko .
INTERNATIONAL JOURNAL OF UROLOGY, 2012, 19 (04) :296-305
[4]   Examination of GyE system for HIMAC carbon therapy [J].
Kanai, T ;
Matsufuji, N ;
Miyamoto, T ;
Mizoe, J ;
Kamada, T ;
Tsuji, H ;
Kato, H ;
Baba, M ;
Tsujii, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :650-656
[5]   Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy [J].
Kanai, T ;
Endo, M ;
Minohara, S ;
Miyahara, N ;
Koyama-Ito, H ;
Tomura, H ;
Matsufuji, N ;
Futami, Y ;
Fukumura, A ;
Hiraoka, T ;
Furusawa, Y ;
Ando, K ;
Suzuki, M ;
Soga, F ;
Kawachi, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (01) :201-210
[6]   Changes in Rectal Dose Due to Alterations in Beam Angles for Setup Uncertainty and Range Uncertainty in Carbon-Ion Radiotherapy for Prostate Cancer [J].
Kubota, Yoshiki ;
Kawamura, Hidemasa ;
Sakai, Makoto ;
Tsumuraya, Ryou ;
Tashiro, Mutsumi ;
Yusa, Ken ;
Kubo, Nobuteru ;
Sato, Hiro ;
Kawahara, Masahiro ;
Katoh, Hiroyuki ;
Kanai, Tatsuaki ;
Ohno, Tatsuya ;
Nakano, Takashi .
PLOS ONE, 2016, 11 (04)
[7]   Proton therapy of prostate cancer by anterior-oblique beams: implications of setup and anatomy variations [J].
Moteabbed, M. ;
Trofimov, A. ;
Sharp, G. C. ;
Wang, Y. ;
Zietman, A. L. ;
Efstathiou, J. A. ;
Lu, H-M .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05) :1644-1660
[8]   A multi-institutional analysis of prospective studies of carbon ion radiotherapy for prostate cancer: A report from the Japan Carbon ion Radiation Oncology Study Group (J-CROS) [J].
Nomiya, Takuma ;
Tsuji, Hiroshi ;
Kawamura, Hidemasa ;
Ohno, Tatsuya ;
Toyama, Shingo ;
Shioyama, Yoshiyuki ;
Nakayama, Yuko ;
Nemoto, Kenji ;
Tsujii, Hirohiko ;
Kamada, Tadashi .
RADIOTHERAPY AND ONCOLOGY, 2016, 121 (02) :288-293
[9]   Evaluation of dose calculation accuracy of treatment planning systems at hip prosthesis interfaces [J].
Paulu, David ;
Alaei, Parham .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03) :9-15
[10]  
Rana S, 2014, J APPL CLIN MED PHYS, V15, P118, DOI [10.1120/jacmp.v15i1.4474, 10.1120/jacmp.v15i3.4611]