Ultrasound-Guided Interscalene Block Anesthesia for Shoulder Arthroscopy

被引:44
作者
Singh, Anshu [1 ]
Kelly, Charles [1 ]
O'Brien, Travis [1 ]
Wilson, Jeffrey [1 ]
Warner, Jon J. P. [1 ]
机构
[1] Orthopaed Ambulatory Surg Ctr Mass Gen W, Waltham, MA USA
关键词
BRACHIAL-PLEXUS BLOCK; REGIONAL ANESTHESIA; NERVE-STIMULATION; GENERAL-ANESTHESIA; MOTOR RESPONSE; GUIDANCE IMPROVES; SUCCESS RATE; SURGERY; PARESTHESIA; INJECTION;
D O I
10.2106/JBJS.K.01418
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ultrasound guidance improves the localization of anesthetic placement during regional anesthesia, but a decreased rate of adverse events has not been demonstrated in the current literature. In this large prospective study, we evaluated the safety, efficacy, and patient satisfaction associated with ultrasound-guided interscalene block. Methods: A cohort of 1319 patients undergoing arthroscopic shoulder surgery at an outpatient surgery center was prospectively evaluated. Interscalene blocks were performed by experienced anesthesiologists and trainees with use of ultrasound guidance. Patients were queried by a physician twenty-four hours postoperatively regarding their satisfaction with the interscalene block and were screened for a comprehensive register of minor and major adverse events. Individuals with adverse events were followed until symptoms resolved. Results: Interscalene block was ultimately successful in 99.6% of the cases. A total of thirty-eight adverse events (prevalence, 2.88%) were noted. At the time of the latest follow-up, permanent sequelae were present in three patients (0.23%), all of whom had relevant comorbidities. With regard to patient satisfaction, 99.06% of the respondents were "satisfied" or "very satisfied" with the interscalene block, whereas 0.94% of respondents were unsatisfied. In addition, 97.8% of the patients stated that they would elect to have an interscalene block again in the future. Conclusions: The present study supports the use of ultrasound-guided interscalene block by trained anesthesiologists for well-screened patients undergoing shoulder arthroscopy, given the high rate of patient satisfaction and the low rate of adverse events.
引用
收藏
页码:2040 / 2046
页数:7
相关论文
共 43 条
[31]   Persistent phrenic nerve paralysis following interscalene brachial plexus block [J].
Robaux, S ;
Bouaziz, H ;
Boisseau, N ;
Raucoules-Aimé, M ;
Laxenaire, MC .
ANESTHESIOLOGY, 2001, 95 (06) :1519-1521
[32]   Characterizing novice behavior associated with learning ultrasound-guided peripheral regional anesthesia [J].
Sites, Brian D. ;
Spence, Brian C. ;
Gallagher, John D. ;
Wiley, Christopher W. ;
Bertrand, Marc L. ;
Blike, George T. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2007, 32 (02) :107-115
[33]   On the edge of the ultrasound screen: Regional anesthesiologists diagnosing nonneural pathology [J].
Sites, Brian D. ;
Spence, Brian C. ;
Gallagher, John D. ;
Beach, Michael L. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2006, 31 (06) :555-562
[34]   A Randomized trial of ultrasound-guided brachial plexus anaesthesia in upper limb surgery [J].
Soeding, PF ;
Sha, S ;
Royse, CF ;
Marks, P ;
Hoy, G ;
Royse, AG .
ANAESTHESIA AND INTENSIVE CARE, 2005, 33 (06) :719-725
[35]  
SUKHANI R, 1994, ANESTH ANALG, V79, P601
[36]   Idiopathic brachial plexitis after total shoulder replacement with interscalene brachial plexus block [J].
Tetzlaff, JE ;
Dilger, J ;
Yap, E ;
Brems, J .
ANESTHESIA AND ANALGESIA, 1997, 85 (03) :644-646
[37]  
TETZLAFF JE, 1993, REGION ANESTH, V18, P30
[38]   Facilitating needle alignment in-plane to an ultrasound beam using a portable laser unit [J].
Tsui, Ban C. H. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2007, 32 (01) :84-88
[39]   Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration [J].
Urmey, WF ;
Stanton, J .
ANESTHESIOLOGY, 2002, 96 (03) :552-554
[40]  
Waibel UG, 1997, ACTA ANAESTH SCAND, V41, P229