Radioguidance for nonpalpable primary lesions and sentinel lymph node(s)

被引:36
作者
Gray, RJ [1 ]
Giuliano, R [1 ]
Dauway, EL [1 ]
Cox, CE [1 ]
Reintgen, DS [1 ]
机构
[1] Univ S Florida, H Lee Moffitt Canc Ctr, Dept Surg, Tampa, FL 33612 USA
关键词
radioguided surgery; sentinel lymph node; wire localization;
D O I
10.1016/S0002-9610(01)00716-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Radioguided surgery can also be used for the simultaneous guidance to a nonpalpable primary tumor and sentinel lymph nodes. Methods: Retrospective review of a prospective database. The surgeon used a gamma probe for guidance to an iodine-125 labeled titanium seed at the primary lesion and technetium-99 labeled sulfur colloid at the sentinel lymph node. Results: Forty-three patients with nonpalpable breast carcinoma underwent dual isotope radioguided surgery. The radioactive seed and primary lesion were retrieved in the first excision in all 44 patients (100%). Eleven patients (25%) had pathologically involved margins. Sentinel lymph node mapping was successful in 42 patients (98%). A mean of 2.4 sentinel nodes were excised and metastatic carcinoma was present in four patients (10%). Conclusions: Dual isotopes can be effectively used in breast cancer patients for simultaneous radioguidance to both a nonpalpable primary lesion and sentinel lymph node and allows for improved logistics. (C) 2001 Excerpta Medica, Inc. All rights reserved.
引用
收藏
页码:404 / 406
页数:3
相关论文
共 10 条
[1]   TRANSGRESSION OF LOCALIZING WIRE INTO THE PLEURAL CAVITY PRIOR TO MAMMOGRAPHY [J].
BRISTOL, JB ;
JONES, PA .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (638) :139-140
[2]  
Cox CE, 1998, ONCOLOGY-NY, V12, P1283
[3]  
Dauway E., 1999, 85 ANN AM COLL SURG, V50
[4]   MIGRATION OF BREAST BIOPSY LOCALIZATION WIRE [J].
DAVIS, PS ;
WECHSLER, RJ ;
FEIG, SA ;
MARCH, DE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (04) :787-788
[5]   Use of technetium-99m-labeled colloid albumin for preoperative and intraoperative localization of nonpalpable breast lesions [J].
Gennari, R ;
Galimberti, V ;
De Cicco, C ;
Zurrida, S ;
Zerwes, F ;
Pigatto, F ;
Luini, A ;
Paganelli, G ;
Veronesi, U .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2000, 190 (06) :692-698
[6]   TRANSECTION OF THE LOCALIZATION HOOKED WIRE DURING BREAST BIOPSY [J].
HOMER, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (05) :929-930
[7]   NEEDLE LOCALIZATION OF OCCULT BREAST-LESIONS WITH A CURVED-END RETRACTABLE WIRE - TECHNIQUE AND PITFALLS [J].
HOMER, MJ ;
PILESPELLMAN, ER .
RADIOLOGY, 1986, 161 (02) :547-548
[8]   National practice patterns of sentinel lymph node dissection for breast carcinoma [J].
Lucci, A ;
Kelemen, PR ;
Miller, C ;
Chardkoff, L ;
Wilson, L .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (04) :453-458
[9]   DOSIMETRIC CHARACTERISTICS OF A DOUBLE-WALL I-125 SOURCE FOR INTERSTITIAL BRACHYTHERAPY [J].
NATH, R ;
MELILLO, A .
MEDICAL PHYSICS, 1993, 20 (05) :1475-1483
[10]   Comparison of mammographically guided breast biopsy techniques [J].
Velanovich, V ;
Lewis, FR ;
Nathanson, SD ;
Strand, VF ;
Talpos, GB ;
Bhandarkar, S ;
Elkus, R ;
Szymanski, W ;
Ferrara, JJ .
ANNALS OF SURGERY, 1999, 229 (05) :625-633