Neutron spectrometer for DD/DT burning ratio measurement in fusion experimental reactor

被引:7
作者
Asai, Keisuke [1 ]
Naoi, Norihiro
Iguchi, Tetsuo
Watanabe, Kenichi
Kawarabayashi, Jun
Nishitani, Takeo
机构
[1] Nagoya Univ, Grad Sch Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Japan Atom Engn Agcy, Ibaraki 3191195, Japan
关键词
plasma diagnostic; DD/DT burning ratio; neutron spectrometer; time-of-flight; proton recoil telescope; Si-SSD; plastic scintillator; ITER;
D O I
10.3327/jnst.43.320
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The most feasible fuels for a fusion reactor are D (Deuterium) and T (Tritium). DD and/or DT fusion reaction or nuclear burning reaction provides two kinds of neutrons, DD neutron and DT neutron, respectively. DD/DT burning ratio, which can be estimated by DD/DT neutron ratio in the burning plasma, is essential for burn control, alpha particle emission rate monitoring and tritium fuel cycle estimation. Here we propose a new neutron spectrometer for the absolute DD/DT burning ratio measurement. The system consists of a Proton Recoil Telescope (PRT) and a Time-of-Flight (TOF) technique. We have conducted preliminary experiments with a prototype detector and a DT neutron beam (phi 20 mm) at the Fusion Neutronics Source, Japan Atomic Energy Agency (JAEA), to assess its basic performance. The detection efficiency obtained by the experiment is consistent with the calculation results in PRT, and sufficient energy resolution for the DD/DT neutron discrimination has been achieved in PRT and TOF. The validity of the Monte Carlo calculation has also been confirmed by comparing the experimental results with the calculation results. The design consideration of this system for use in ITER (International Thermonuclear Experimental Reactor) has shown that this system is capable of monitoring the line-integrated DD/DT burning ratio for the plasma core line of sight with the required measurement accuracy of 20% in the upper 4 decades of the ITER operation (fusion power: 100 kW-700 MW).
引用
收藏
页码:320 / 324
页数:5
相关论文
共 16 条
[1]   Neutron emission spectroscopy at JET -: Results from the magnetic proton recoil spectrometer (invited) [J].
Ericsson, G ;
Ballabio, L ;
Conroy, S ;
Frenje, J ;
Henriksson, H ;
Hjalmarsson, A ;
Källne, J ;
Tardocchi, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :759-766
[2]  
HARANO H, 1996, J PLASMA FUSION RES, V72, P681
[3]   Neutron spectrometry for D-T plasmas in JET, using a tandem annular-radiator proton-recoil spectrometer [J].
Hawkes, NP ;
Bond, DS ;
Kiptily, V ;
Jarvis, ON ;
Conroy, SW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2) :490-494
[4]   Development of 14 MeV neutron spectrometer for fusion experimental reactor [J].
Iguchi, T ;
Takada, E ;
Nakazawa, M ;
Kaneko, J ;
Nishitani, T ;
Matoba, T ;
Ikeda, Y .
FUSION ENGINEERING AND DESIGN, 1997, 34-35 :585-589
[5]   Analysis of neutron cameras for ITER [J].
Johnson, LC ;
Barnes, CW ;
Batistoni, P ;
Fiore, C ;
Janeschitz, G ;
Khripunov, V ;
Krasilnikov, A ;
Marcus, FB ;
Nishitani, T ;
Sadler, G ;
Sasao, M ;
Zaveriaev, V .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :1145-1148
[6]  
Kallne J, 1997, REV SCI INSTRUM, V68, P581, DOI 10.1063/1.1147658
[7]  
KALLNE J, 1991, REV SCI INSTRUM, V62, P2871, DOI 10.1063/1.1142174
[8]  
Källne J, 1999, REV SCI INSTRUM, V70, P1181, DOI 10.1063/1.1149335
[9]   Response function measurement of a synthetic diamond radiation detector for 14 MeV neutrons [J].
Kaneko, J ;
Ikeda, Y ;
Nishitani, T ;
Katagiri, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :1100-1103
[10]   Fusion neutronic source deuterium-tritium neutron spectrum measurements using natural diamond detectors [J].
Krasilnikov, AV ;
Kaneko, J ;
Isobe, M ;
Maekawa, F ;
Nishitani, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (04) :1720-1724