Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source

被引:26
|
作者
Saam, Tobias [1 ]
Herzen, Julia [2 ,7 ]
Hetterich, Holger [1 ]
Fill, Sandra [1 ]
Willner, Marian [2 ]
Stockmar, Marco [2 ]
Achterhold, Klaus [2 ]
Zanette, Irene [3 ]
Weitkamp, Timm [4 ]
Schueller, Ulrich [5 ]
Auweter, Sigrid [1 ]
Adam-Neumair, Silvia [6 ]
Nikolaou, Konstantin [1 ]
Reiser, Maximilian F. [1 ]
Pfeiffer, Franz [2 ]
Bamberg, Fabian [1 ]
机构
[1] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[2] Tech Univ Munich, Chair Biomed Phys, D-80290 Munich, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Synchrotron Soleil, Gif Sur Yvette, France
[5] Ludwig Maximilians Univ Hosp, Ctr Neuropathol, Munich, Germany
[6] Univ Munich, Inst Anat, Munich, Germany
[7] Helmholtz Zentrum Geesthacht, Inst Mat Res, Geesthacht, Germany
来源
PLOS ONE | 2013年 / 8卷 / 09期
基金
欧洲研究理事会;
关键词
TOMOGRAPHY; RISK; IVUS;
D O I
10.1371/journal.pone.0073513
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: Phase-contrast imaging is a novel X-ray based technique that provides enhanced soft tissue contrast. The aim of this study was to evaluate the feasibility of visualizing human carotid arteries by grating-based phase-contrast tomography (PC-CT) at two different experimental set-ups: (i) applying synchrotron radiation and (ii) using a conventional X-ray tube. Materials and Methods: Five ex-vivo carotid artery specimens were examined with PC-CT either at the European Synchrotron Radiation Facility using a monochromatic X-ray beam (2 specimens; 23 keV; pixel size 5.4 mu m), or at a laboratory set-up on a conventional X-ray tube (3 specimens; 35-40 kVp; 70 mA; pixel size 100 mu m). Tomographic images were reconstructed and compared to histopathology. Two independent readers determined vessel dimensions and one reader determined signal-to-noise ratios (SNR) between PC-CT and absorption images. Results: In total, 51 sections were included in the analysis. Images from both set-ups provided sufficient contrast to differentiate individual vessel layers. All PCI-based measurements strongly predicted but significantly overestimated lumen, intima and vessel wall area for both the synchrotron and the laboratory-based measurements as compared with histology (all p<0.001 with slope >0.53 per mm(2), 95%-CI: 0.35 to 0.70). Although synchrotron-based images were characterized by higher SNRs than laboratory-based images; both PC-CT set-ups had superior SNRs compared to corresponding conventional absorption-based images (p<0.001). Inter-reader reproducibility was excellent (ICCs >0.98 and >0.84 for synchrotron and for laboratory-based measurements; respectively). Conclusion: Experimental PC-CT of carotid specimens is feasible with both synchrotron and conventional X-ray sources, producing high-resolution images suitable for vessel characterization and atherosclerosis research.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Edge illumination X-ray phase-contrast imaging: nanoradian sensitivity at synchrotrons and translation to conventional sources
    Diemoz, P. C.
    Endrizzi, M.
    Hagen, C. K.
    Rau, C.
    Bravin, A.
    Speller, R. D.
    Robinson, I. K.
    Olivo, A.
    22ND INTERNATIONAL CONGRESS ON X-RAY OPTICS AND MICROANALYSIS, 2014, 499
  • [2] Propagation-based Phase-Contrast X-ray Imaging at a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Hehn, Lorenz
    Guenther, Benedikt
    Yildirim, Ali Oender
    Gleich, Bernhard
    Achterhold, Klaus
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2017, 7
  • [3] Phase-Contrast Imaging in a Polychromatic X-ray Beam at a Laboratory Source
    Krivonosov, Yu. S.
    Asadchikov, V. E.
    Buzmakov, A. V.
    CRYSTALLOGRAPHY REPORTS, 2020, 65 (04) : 503 - 507
  • [4] Comparison of two x-ray phase-contrast imaging methods with a microfocus source
    Zhou, T.
    Lundstrom, U.
    Thuering, T.
    Rutishauser, S.
    Larsson, D. H.
    Stampanoni, M.
    David, C.
    Hertz, H. M.
    Burvall, A.
    OPTICS EXPRESS, 2013, 21 (25): : 30183 - 30195
  • [5] From synchrotron radiation to lab source: advanced speckle-based X-ray imaging using abrasive paper
    Wang, Hongchang
    Kashyap, Yogesh
    Sawhney, Kawal
    SCIENTIFIC REPORTS, 2016, 6
  • [6] X-ray phase-contrast imaging: the quantum perspective
    Slowik, J. M.
    Santra, R.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2013, 46 (16)
  • [7] Noise in x-ray grating-based phase-contrast imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Ritter, Andre
    Anton, Gisela
    MEDICAL PHYSICS, 2011, 38 (07) : 4133 - 4140
  • [8] Contrast transfer function in grating-based x-ray phase-contrast imaging
    Huang, Jianheng
    Du, Yang
    Lin, Danying
    Liu, Xin
    Niu, Hanben
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 747 : 13 - 18
  • [9] Analyzer-based phase-contrast imaging system using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan
    Brankov, Jovan G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (08)
  • [10] In vivo Dynamic Phase-Contrast X-ray Imaging using a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Guenther, Benedikt
    Hehn, Lorenz
    Moeller, Winfried
    Kutschke, David
    Yang, Lin
    Donnelley, Martin
    Murrie, Rhiannon
    Erl, Alexander
    Stoeger, Tobias
    Gleich, Bernhard
    Achterhold, Klaus
    Schmid, Otmar
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2018, 8