Optimal needle size for thyroid fine needle aspiration cytology

被引:22
作者
Tanaka, Aki [1 ]
Hirokawa, Mitsuyoshi [2 ]
Higuchi, Miyoko [1 ]
Kanematsu, Risa [1 ]
Suzuki, Ayana [1 ]
Kuma, Seiji [2 ]
Hayashi, Toshitetsu [2 ]
Kudo, Takumi [3 ]
Miyauchi, Akira [4 ]
机构
[1] Kuma Hosp, Dept Clin Lab, Kobe, Hyogo, Japan
[2] Kuma Hosp, Dept Diagnost Pathol & Cytol, Kobe, Hyogo, Japan
[3] Kuma Hosp, Dept Internal Med, Kobe, Hyogo, Japan
[4] Kuma Hosp, Dept Surg, Kobe, Hyogo, Japan
关键词
Thyroid; Aspiration cytology; Fine needle aspiration; Needle size; Pain; SAMPLE ADEQUACY; PAIN-SCALE; BIOPSY; NODULE;
D O I
10.1507/endocrj.EJ18-0422
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Concerning the needle size for thyroid fine needle aspiration cytology (FNAC), 25-27 -gauge needles are generally used in Western countries. However, in Japan, the use of larger needles (21-22-gauge needles) is common. The aim of our study was to determine the optimal needle size for thyroid FNAC. We performed ultrasound-guided FNAC for 200 thyroid nodules in 200 patients using two different-sized needles (22 and 25 gauge). For each nodule, two passes with the different-sized needles were performed. The order of needle sizes was reversed for the second group of 100 nodules. The second aspiration was more painful than the first, regardless of the needle size. An association with more severe blood contamination was more frequently observed with the use of 22 -gauge needles (32.0%) than with the use of 25-gauge needles (17.5%) and in the second aspiration (37.5%) than in the initial aspiration (12.0%). The initial aspiration samples were more cellular than the second aspiration samples. Regarding the unsatisfactory and malignancy detection rates. there was no statistical difference between the needles. In three of seven markedly calcified nodules, it was difficult to insert 25-gauge needles into the nodules. In terms of the diagnostic accuracy and pain, either needle size can be used. We recommend using 22-gauge needles for markedly calcified nodules because 25-gauge needles bend more easily in such cases. We demonstrated that the initial aspiration tended to obtain more cellular samples and to be less contaminated. Thus, the initial aspiration is more important and should be closely attended.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 25 条
  • [1] The National Cancer Institute Thyroid fine needle aspiration state of the science conference: a summation
    Baloch, Zubair W.
    Cibas, Edmund S.
    Clark, Douglas P.
    Layfield, Lester J.
    Ljung, Britt-Marie
    Pitman, Martha Bishop
    Abati, Andrea
    [J]. CYTOJOURNAL, 2008, 5
  • [2] Overview of Diagnostic Terminology and Reporting
    Baloch, Zubair W.
    Alexander, Erik K.
    Gharib, Hossein
    Raab, Stephen S.
    [J]. BETHESDA SYSTEM FOR REPORTING THYROID CYTOPATHOLOGY: DEFINITIONS, CRITERIA AND EXPLANATORY NOTES, 2010, : 1 - +
  • [3] Fine-Needle Aspiration Cytology of Thyroid Nodule: Does the Needle Matter?
    Cappelli, Carlo
    Pirola, Ilenia
    Gandossi, Elena
    De Martino, Elena
    Agosti, Barbara
    Castellano, Maurizio
    [J]. SOUTHERN MEDICAL JOURNAL, 2009, 102 (05) : 498 - 501
  • [4] Does Large Needle Aspiration Biopsy Add Pain to the Thyroid Nodule Evaluation?
    Carpi, Angelo
    Rossi, Giuseppe
    Nicolini, Andrea
    Iervasi, Giorgio
    Russo, Matteo
    Mechanick, Jeffrey
    [J]. PLOS ONE, 2013, 8 (03):
  • [5] Ultrasound-guided thyroid nodule fine-needle biopsies - comparison of sample adequacy with different sampling techniques, different needle sizes, and with/without onsite cytological analysis
    Cerit, Mahinur
    Yucel, Cem
    Gocun, Pinar Uyar
    Poyraz, Aylar
    Cerit, Ethem Turgay
    Taneri, Ferit
    [J]. ENDOKRYNOLOGIA POLSKA, 2015, 66 (04) : 295 - 300
  • [6] The 2017 Bethesda System for Reporting Thyroid Cytopathology
    Cibas, Edmund S.
    Ali, Syed Z.
    [J]. THYROID, 2017, 27 (11) : 1341 - 1346
  • [7] CROTHERS BA, 2018, BETHESDA SYSTEM REPO, P7
  • [8] Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material
    Degirmenci, B.
    Haktanir, A.
    Albayrak, R.
    Acar, M.
    Sahin, D. A.
    Sahin, O.
    Yucel, A.
    Caliskan, G.
    [J]. CLINICAL RADIOLOGY, 2007, 62 (08) : 798 - 803
  • [9] Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules
    Gumus, Mehmet
    Cay, Nurdan
    Algin, Oktay
    Ipek, Ali
    Ersoy, Reyhan Unlu
    Belenli, Olcay
    Ugras, Serdar
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2012, 18 (01) : 102 - 105
  • [10] HANBIDGE AE, 1995, CAN ASSOC RADIOL J, V46, P199