Effect of the Configurations of Fiducial Markers on the Accuracy of Surgical Navigation in Zygomatic Implant Placement: An In Vitro Study

被引:33
|
作者
Fan, Shengchi [1 ,2 ,3 ]
Hung, Kuofeng [1 ,2 ,3 ,4 ]
Bornstein, Michael M. [4 ]
Huang, Wei [2 ,3 ,5 ]
Wang, Feng [2 ,3 ,5 ]
Wu, Yiqun [1 ,2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Natl Clin Res Ctr Oral Dis, Dent Clin 2,Dept Oral Implantol,Coll Stomatol,Sch, Shanghai, Peoples R China
[2] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[3] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[4] Univ Hong Kong, Fac Dent, Oral & Maxillofacial Radiol Appl Oral Sci, Hong Kong, Peoples R China
[5] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Natl Clin Res Ctr Oral Dis, Dept Oral Implantol,Coll Stomatol,Sch Med, Shanghai, Peoples R China
基金
国家重点研发计划;
关键词
accuracy; edentulous; navigation system; registration; zygomatic implant; TARGET REGISTRATION; SURGERY; ERROR; RECONSTRUCTION; MANAGEMENT; MODALITIES;
D O I
10.11607/jomi.6821
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Real-time surgical navigation has been increasingly applied in implant placement. The initial registration procedures were found to substantially affect the overall accuracy, but the number and distribution of fiducial markers are yet undetermined. This study aimed to determine the minimal number and optimal distribution of fiducial markers to achieve clinically acceptable accuracy in surgical navigation for zygomatic implant placement by systematically analyzing the effects of different setups of fiducial markers on target registration error (TRE). Materials and Methods: A maxillary phantom with bone-anchored fiducial markers was scanned using cone beam computed tomography, followed by data processing on Brainlab, a commercially available navigation system. A total of 10 miniscrews were inserted in the edentulous maxilla for the configuration of the fiducial markers, with another two miniscrews as implant targets to assess the TRE in zygomatic bone. Data were then collected in nine configurations with distinct fiducial numbers and positions. Statistical analyses were performed with SPSS. Results: The accuracy of the surgical navigation system was found to depend on both the number and the position of fiducial markers. No significant difference was observed in accuracy among groups with eight fiducials and with a polygon span distribution (P > .05). When the fiducial number decreased to less than six, the markers inserted in a regular triangle were more precise than those in an inverse triangle configuration. When the number of fiducials was five with a polygonal distribution, a low TRE value of 0.59 mm was detected, which was comparable to the accuracy with more than eight fiducials in this study. Conclusion: A scattered distribution with a polygon span with at least five fiducial markers in the edentulous maxilla for registration seems to achieve acceptable TRE values with high accuracy for navigation in zygomatic implant placement.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [21] Real-Time Surgical Navigation System for the Placement of Zygomatic Implants with Severe Bone Deficiency
    Hung, Kuofeng
    Huang, Wei
    Wang, Feng
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1444 - 1449
  • [22] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99
  • [23] Effect of the use of a surgical guide on heat generation during implant placement: A comparative in vitro study
    Alhroob, Khaldoun Hossein
    Alsabbagh, Mohammed Monzer
    Alsabbagh, Aghiad Yassin
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (01) : 55 - 59
  • [24] Accuracy of 3 calibration methods of computer-assisted dynamic navigation for implant placement: An in vitro study
    Pei, Xiyan
    Liu, Xiaoqiang
    Iao, Siniong
    Ma, Feifei
    Li, Hong
    Sun, Feng
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 668 - 674
  • [25] ACCURACY OF IMPLANT PLACEMENT USING PRECISION SURGICAL GUIDES WITH VARYING OCCLUSOGINGIVAL HEIGHTS: AN IN VITRO STUDY
    Park, Chanseop
    Raigrodski, Ariel J.
    Rosen, Jacob
    Spiekerman, Charles
    London, Robert M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (06): : 372 - 381
  • [26] Comparison of the accuracy of two different dynamic navigation system registration methods for dental implant placement: A retrospective study
    Ma, Feifei
    Sun, Feng
    Wei, Tai
    Ma, Yu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (03) : 352 - 360
  • [27] Comparative Evaluation of the Accuracy of Dynamic Navigation and Free Hand Methods During Zygomatic Implant Placement: A Randomized Controlled Trial
    Penmetsa, Gautami S.
    Shah, Rahul Manhar
    Raju, M. A. K. V.
    Gadde, Praveen
    Venkata, Ramaraju Alluri
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (05) : 468 - 473
  • [28] Accuracy of dynamic navigation compared to static surgical guides and the freehand approach in implant placement: a prospective clinical study
    Younis, Hamza
    Lv, Chengpeng
    Xu, Boya
    Zhou, Huixia
    Du, Liangzhi
    Liao, Lifan
    Zhao, Ningbo
    Long, Wen
    Elayah, Sadam Ahmed
    Chang, Xiaofeng
    He, Longlong
    HEAD & FACE MEDICINE, 2024, 20 (01)
  • [29] Accuracy Evaluation of Computed Tomography-Derived Stereolithographic Surgical Guides in Zygomatic Implant Placement in Human Cadavers
    Chrcanovic, Bruno R.
    Oliveira, Davidson R.
    Custodio, Antonio L.
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (05) : 345 - 356
  • [30] Accuracy of implant placement using CAD-CAM tooth-supported surgical guides for an auricular prosthesis in vitro
    Fan, Yiping
    Wei, Hongbo
    Zhao, Ruifeng
    Lin, Xiuwen
    Bai, Shizhu
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (01): : 70 - 76