PURPOSE: Evaluate the visual performance of the AcrySof ReSTOR intraocular lens (IOL) and compare it with the monofocal SA60AT IOL. DESIGN: Prospective, nonrandomized, clinical trial. METHODS: Forty patients (80 eyes) from the Federal University of Sao Paulo were enrolled in two groups. Twenty-five patients were assigned to the ReSTOR group and 15 patients to the monofocal group. Inclusion criteria were corneal astigmatism < 1.0 diopter, potential acuity meter > 0.2 logMAR units, and no associated ocular diseases. Parameters analyzed included distance uncorrected and best-corrected visual acuity, near uncork rected and distance corrected visual acuity, intermediate visual acuity, contrast sensitivity (Pelli-Robson chart), stereopsis (Titmus test), reading speed, wavefront measurement (LADARWave aberrometer), and a quality-of-life questionnaire. MAIN OUTCOME MEASURE: Distance and near uncorrected and best distance corrected visual acuity, contrast sensitivity, and reading speed. RESULTS: Distance uncorrected and best-corrected visual acuity in the ReSTOR group were not statistically different from the monofocal group (P = .66). Near uncorrected and distance corrected visual acuity were statistically better in the ReSTOR group than the monofocal group (0.16 +/- 0.13 vs 0.62 +/- 0.09, P < .001, and 0.14 +/- 0.12 vs 0.62 +/- 0.07, P < .001, respectively). The ReSTOR group demonstrated less spherical aberrations compared with the monofocal group (P < .001). Monocular photopic contrast sensitivity was statistically lower in the ReSTOR group (P < .001). Stereopsis and reading speed were not statistically different between the groups. CONCLUSION: The AcrySof ReSTOR IOL provides a satisfactory full range of vision and achieves a more satisfactory quality of life when compared with the monofocal SA60AT IOL, but with lower contrast sensitivity.
引用
收藏
页码:827 / 832
页数:6
相关论文
共 27 条
  • [1] CONTRAST SENSITIVITY AND READING THROUGH MULTIFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    LINDSTROM, RL
    ZABEL, RW
    KIRBY, VM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (08) : 1076 - 1080
  • [2] Binocular function after bilateral implantation of monofocal and refractive multifocal intraocular lenses
    Arens, B
    Freudenthaler, N
    Quentin, CD
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (03) : 399 - 404
  • [3] Bellucci Roberto, 2005, Curr Opin Ophthalmol, V16, P33, DOI 10.1097/00055735-200502000-00006
  • [4] Boerner C F, 1984, J Am Intraocul Implant Soc, V10, P49
  • [5] MULTIFOCAL INTRAOCULAR LENSES
    DUFFEY, RJ
    ZABEL, RW
    LINDSTROM, RL
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04) : 423 - 429
  • [6] ELLIOTT DB, 1992, OPHTHAL PHYSL OPT, V12, P275, DOI 10.1111/j.1475-1313.1992.tb00397.x
  • [7] Glasser A, 1999, VISION RES, V39, P209
  • [8] OPTICAL-PERFORMANCE OF MULTIFOCAL INTRAOCULAR LENSES
    HOLLADAY, JT
    VANDIJK, H
    LANG, A
    PORTNEY, V
    WILLIS, TR
    SUN, R
    OKSMAN, HC
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04) : 413 - 422
  • [9] VISUAL EVOKED-POTENTIAL LATENCY AND CONTRAST SENSITIVITY IN PATIENTS WITH POSTERIOR CHAMBER INTRAOCULAR-LENS IMPLANTS
    HOWE, JW
    MITCHELL, KW
    MAHABALESWARA, M
    ABDELKHALEK, MN
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1986, 70 (12) : 890 - 894
  • [10] Huber C, 1981, J Am Intraocul Implant Soc, V7, P244