Canine sternal force-displacement relationship during cardiopulmonary resuscitation

被引:11
作者
Gruben, KG [1 ]
Halperin, HR
Popel, AS
Tsitlik, JE
机构
[1] Johns Hopkins Univ & Med Inst, Peter Belfer Cardiac Mech Lab, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ & Med Inst, Dept Med, Div Cardiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ & Med Inst, Dept Biomed Engn, Baltimore, MD 21287 USA
[4] ServiceMaster Management Serv Co, Chicago, IL 60612 USA
关键词
biomechanics; canine; cardiopulmonary resuscitation; elasticity; human; model; thorax; viscosity;
D O I
10.1109/10.771188
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A viscoelastic model developed to model human sternal response to the cyclic loading of manual cardiopulmonary resuscitation (CPR) [8] was used to evaluate the properties of canine chests during CPR, Sternal compressions with ventilations after every fifth compression were applied to supine canines (n = 7) with a mechanical resuscitation device. The compressions were applied at a nominal rate of 90/min with a peak force near 400 N, From measurements of sternal force, sternal displacement, and tracheal airflow, model parameters were estimated and their dependence on time and lung volume evaluated. The position to which the chest recoiled between compressions changed with time at a mean rate of 1.0 mm/min, Within each ventilation cycle (five compressions) the sternal recoil position decreased by 2.0 cm for each liter of decrease in lung volume, The elastic force and damping decreased with time and decreasing lung volume, Canine and human [8] model parameters were found to be similar despite the notable differences in thoracic anatomy between the species, supporting the continued use of canines as models for human CPR, These parameters may be useful in the development of a model relating sternal compression forces to blood flow during CPR.
引用
收藏
页码:788 / 796
页数:9
相关论文
共 16 条
  • [1] *AM HEART ASS, 1987, TXB ADV CARD LIF SUP, P1
  • [2] THEORETICALLY OPTIMAL DUTY CYCLES FOR CHEST AND ABDOMINAL COMPRESSION DURING EXTERNAL CARDIOPULMONARY-RESUSCITATION
    BABBS, CF
    THELANDER, K
    [J]. ACADEMIC EMERGENCY MEDICINE, 1995, 2 (08) : 698 - 707
  • [3] OBSERVATIONS OF HEMODYNAMICS DURING HUMAN CARDIOPULMONARY-RESUSCITATION
    CHANDRA, NC
    TSITLIK, JE
    HALPERIN, HR
    GUERCI, AD
    WEISFELDT, ML
    [J]. CRITICAL CARE MEDICINE, 1990, 18 (09) : 929 - 934
  • [4] MECHANISM OF BLOOD-FLOW GENERATED BY PRECORDIAL COMPRESSION DURING CPR .1. STUDIES ON CLOSED CHEST PRECORDIAL COMPRESSION
    DESHMUKH, HG
    WEIL, MH
    GUDIPATI, CV
    TREVINO, RP
    BISERA, J
    RACKOW, EC
    [J]. CHEST, 1989, 95 (05) : 1092 - 1099
  • [5] SEQUENCE OF MITRAL-VALVE MOTION AND TRANSMITRAL BLOOD-FLOW DURING MANUAL CARDIOPULMONARY-RESUSCITATION IN DOGS
    FENELEY, MP
    MAIER, GW
    GAYNOR, JW
    GALL, SA
    KISSLO, JA
    DAVIS, JW
    RANKIN, JS
    [J]. CIRCULATION, 1987, 76 (02) : 363 - 375
  • [6] ON THE IMPERFECT ELASTICITY OF LUNG-TISSUE
    FREDBERG, JJ
    STAMENOVIC, D
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (06) : 2408 - 2419
  • [7] SYSTEM FOR MECHANICAL MEASUREMENTS DURING CARDIOPULMONARY RESUSCITATION IN HUMANS
    GRUBEN, KG
    ROMLEIN, J
    HALPERIN, HR
    TSITLIK, JE
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (02) : 204 - 210
  • [8] STERNAL FORCE-DISPLACEMENT RELATIONSHIP DURING CARDIOPULMONARY-RESUSCITATION
    GRUBEN, KG
    GUERCI, AD
    HALPERIN, HR
    POPEL, AS
    TSITLIK, JE
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (02): : 195 - 201
  • [9] DETERMINANTS OF BLOOD-FLOW TO VITAL ORGANS DURING CARDIOPULMONARY-RESUSCITATION IN DOGS
    HALPERIN, HR
    TSITLIK, JE
    GUERCI, AD
    MELLITS, ED
    LEVIN, HR
    SHI, AY
    CHANDRA, N
    WEISFELDT, ML
    [J]. CIRCULATION, 1986, 73 (03) : 539 - 550
  • [10] INTRATHORACIC PRESSURE-FLUCTUATIONS MOVE BLOOD DURING CPR - COMPARISON OF HEMODYNAMIC DATA WITH PREDICTIONS FROM A MATHEMATICAL-MODEL
    HALPERIN, HR
    TSITLIK, JE
    BEYAR, R
    CHANDRA, N
    GUERCI, AD
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1987, 15 (3-4) : 385 - 403