The sustained partial discharge (PD) for a long time degrades the dielectric liquid and eventually leads to the total failure of the high voltage (HV) power equipment. Therefore, monitoring and measuring the PD is a vital task to safeguard the HV power equipment used in the power system network. To execute the PD activity in the HV laboratory, a prototype liquid dielectric test cell with needle-plane electrode arrangement has been used as per IEC 60270. The proposed work focuses on Acoustic Emission (AE) technique as an online condition monitoring tool for finding out the solution related to the PD activity inside the dielectric test cell. The obtained results confirm that AE method has a great potential to analyse the PD activity efficiently. Further, PD-affected transformer oil samples have also been analysed with UV-visible spectroscopy and the obtained results showed that it has the ability to know the quality of the degraded oil samples.
引用
收藏
页数:4
相关论文
共 10 条
[1]   Location of PD Sources in Power Transformers by UHF and Acoustic Measurements [J].
Coenen, Sebastian ;
Tenbohlen, Stefan .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) :1934-1940
[2]   Pattern recognition techniques for power transformer insulation diagnosisa comparative study part 1: framework, literature, and illustration [J].
Cui, Yi ;
Ma, Hui ;
Saha, Tapan .
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (10) :2247-2259
[3]   UV spectroscopy of GK transformer oil [J].
Gafiyatullin, L. G. ;
Turanova, O. A. ;
Kozlov, V. K. ;
Turanov, A. N. .
OPTICS AND SPECTROSCOPY, 2010, 109 (01) :97-100
[4]   Effect of ageing in transformer oil using UV-visible spectrophotometeric technique [J].
Karmakar S. ;
Roy N.K. ;
Kumbhakar P. .
Journal of Optics, 2011, 40 (2) :33-38
[5]  
Lee SJ, 2013, IEEE T DIELECT EL IN, V20, P691
[6]   On the estimation.of elapsed life of oil-immersed power transformers [J].
Pradhan, MK ;
Ramu, TS .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) :1962-1969
[7]   Electro-acoustic Detection, Identification and Location of Partial Discharge Sources in Oil-paper Insulation Systems [J].
Rubio-Serrano, J. ;
Rojas-Moreno, M. V. ;
Posada, J. ;
Martinez-Tarifa, J. M. ;
Robles, G. ;
Garcia-Souto, J. A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (05) :1569-1578
[8]  
Stone G. C., 2012, IEEE ELECT INSULATIO, V28
[9]   Modeling of Early Stage Partial Discharge and Overheating Degradation of Paper-oil Insulation [J].
Tsuchie, Motoo ;
Kozako, Masahiro ;
Hikita, Masayuki ;
Sasaki, Ei .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) :1342-1349
[10]  
Veloso Giscard Franceire Cintra, 2007, ARTIFICIAL INTELLIGE, V1