Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate192Ir brachytherapy

被引:21
|
作者
Rosales, Haydee M. Linares [1 ,2 ,3 ]
Archambault, Louis [1 ,2 ,3 ]
Beddar, Sam [4 ,5 ]
Beaulieu, Luc [1 ,2 ,3 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[2] Univ Laval, Ctr Rech Sur Canc, Quebec City, PQ, Canada
[3] Univ Laval, Dept Radiooncol & Axe Oncol, CRCHU Quebec, CHU Quebec, Quebec City, PQ, Canada
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[5] Univ Texas MD Anderson, UTHlth, Grad Sch Biomed Sci, Houston, TX USA
基金
加拿大自然科学与工程研究理事会;
关键词
HDR brachytherapy; in vivodosimetry; multipoint plastic scintillator detector; plastic scintillator; source tracking; ENERGY BEAM DOSIMETRY; IN-VIVO DOSIMETRY; THERMOLUMINESCENCE DOSIMETRY; TEMPERATURE-DEPENDENCE; MONTE-CARLO; DETECTORS; PHOTON; VERIFICATION; ELECTRON; LIGHT;
D O I
10.1002/mp.14246
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study aims to present the performance of a multipoint plastic scintillation detector (mPSD) as a tool for real-time dose measurements (covering three orders of magnitude in dose rate), source-position triangulation, and dwell time assessment in high dose rate (HDR) brachytherapy. Methods A previously characterized and optimized three-point sensor system was used for HDR brachytherapy measurements. The detector was composed of three scintillators: BCF60, BCF12, and BCF10. Scintillation light was transmitted through a single 1-mm-diameter clear optical fiber and read by a compact assembly of photomultiplier tubes (PMTs). Each component was numerically optimized to allow for signal deconvolution using a multispectral approach, taking care of the Cerenkov stem effect as well as extracting the dose from each scintillator. The PMTs were read simultaneously using a data acquisition board at a rate of 100 KHz and controlled with in-house software based on Python. An192Irsource (Flexitron, Elekta-Brachy) was remotely controlled and sent to various positions in a in-house PMMA holder, ensuring 0.1 mm positional accuracy. Dose measurements covering a range of 10 cm of source movement were carried out according to TG-43 U1 recommendations. Water measurements were performed in order to: (a) characterize the system's response in terms of angular dependence; (b) obtain the relative contribution of positioning and measurement uncertainties to the total system uncertainty; (c) assess the system's temporal resolution; and (d) track the source position in real time. The triangulation principle was applied to report the source position in three-dimensional space. Results As expected, the positioning uncertainty dominated close to the source, whereas the measurement uncertainty dominated at larger distances. A maximum measurement uncertainty of 17 % was observed for the BCF60 scintillator at 10 cm from the source. Based on the uncertainty chain, the best compromises between positioning and measurement uncertainties were reached at 17.2, 17.4, and 17.5 mm for the BCF10, BCF12, and BCF60 scintillators, respectively, which also corresponded to the recommended optimal distances to the source for calibration purposes. The detector further exhibited no angular dependence. All dose values were found to be within 2% of the dose value at90 circle. In the experiments performed for source-position determination, the system provided an average location with a standard deviation under 1.7 mm. The maximum observed differences between measured and expected values were 1.82 and 1.8 mm in the x- and z-directions, respectively. Deviations between the mPSD measurements and expected TG-43 values were below 5% in all the explored measurement conditions. With regard to dwell time measurement accuracy, the maximum deviation observed at all distances was 0.56 +/- 0.25 s, with a weighted average of the three scintillators below 0.33 +/- 0.37 s at all distances covered in this study. Conclusions Real-time HDR brachytherapy measurements were performed with an optimized mPSD system. The performance of the system demonstrated that it could be used for simultaneous, in vivo, real-time reporting of dose, dwell time, and source position during HDR brachytherapy.
引用
收藏
页码:4477 / 4490
页数:14
相关论文
共 44 条
  • [1] Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy
    Rosales, Haydee M. Linares
    Duguay-Drouin, Patricia
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2019, 46 (05) : 2412 - 2421
  • [2] On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy
    Therriault-Proulx, Francois
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] In vivo real-time dosimetric verification in high dose rate prostate brachytherapy
    Seymour, Erin L.
    Downes, Simon J.
    Fogarty, Gerald B.
    Izard, Michael A.
    Metcalfe, Peter
    MEDICAL PHYSICS, 2011, 38 (08) : 4785 - 4794
  • [4] Real-time in vivo dosimetry in high dose rate prostate brachytherapy
    Mason, Josh
    Mamo, Arielle
    AI-Qaisieh, Bashar
    Henry, Ann M.
    Bownes, Peter
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 333 - 338
  • [5] Monte Carlo dosimetric characterization of a new high dose rate 169Yb brachytherapy source and independent verification using a multipoint plastic scintillator detector
    Famulari, Gabriel
    Linares Rosales, Haydee M.
    Dupere, Justine
    Medich, David C.
    Beaulieu, Luc
    Enger, Shirin A.
    MEDICAL PHYSICS, 2020, 47 (09) : 4563 - 4573
  • [6] Real-time tracking of source movement by Cherenkov emission imaging for high-dose-rate brachytherapy
    Yogo, K.
    Tatsuno, Y.
    Shimo, T.
    Noguchi, Y.
    Okudaira, K.
    Nozawa, M.
    Ishiyama, H.
    Yasuda, H.
    Oguchi, H.
    Yamamoto, S.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (07):
  • [7] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [8] Development of an All-in-One Phantom and Scintillator Radiation Sensor for Real-Time Monitoring of Source Position and Dose Distribution in High-Dose-Rate Brachytherapy
    Shin, Sang Hun
    Yoo, Wook Jae
    Jang, Kyoung Won
    Cho, Seunghyun
    Kim, Kum Bae
    Lee, Bongsoo
    SENSORS AND MATERIALS, 2016, 28 (06) : 619 - 624
  • [9] A technique for calibrating a high dose rate 192Ir brachytherapy source
    Fourie, O. L.
    Crabtree, T. G.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 85 - 92
  • [10] Evaluating dosimetric accuracy of the 6 MV calibration on EBT3 film in the use of Ir-192 high dose rate brachytherapy
    Huang, Lyu
    Gaballa, Hani
    Chang, Jenghwa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):