In Vitro S. epidermidis and S. aureus Adherence to Composite and Lightweight Polypropylene Grafts

被引:34
作者
Aydinuraz, Kuzey [1 ]
Agalar, Canan [2 ]
Agalar, Fatih [1 ]
Ceken, Sabahat [2 ]
Duruyurek, Nihal [2 ]
Vural, Tayfun [3 ]
机构
[1] Kirikkale Univ, Sch Med, Suleyman Demirel Res & Training Hosp, Dept Gen Surg, Kirikkale, Turkey
[2] Kirikkale Univ, Sch Med, Suleyman Demirel Res & Training Hosp, Dept Infect Dis & Clin Microbiol, Kirikkale, Turkey
[3] Hacettepe Univ, Fac Sci, Dept Chem, Nanotechnol & Nanomed Div, Ankara, Turkey
关键词
polypropylene mesh; composite mesh; lightweight mesh; bacterial adherence; S; Epidermidis; Aureus; scanning electron microscopy;
D O I
10.1016/j.jss.2009.04.008
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Despite the significant risk of infection, prosthetic graft materials have become indispensable for incisional hernia repair. Composite and lightweight grafts have been developed to overcome adhesion and rigidity. The aim of this study was to evaluate in vitro S. epidermidis and S. aureus adherence to these new generation grafts, which have modified composition and textile properties. Materials and Methods. In this experimental study, sterile samples of multifilament polypropylene, multifilament lightweight composite, monofilament composite, and monofilament polypropylene grafts were incubated with slime positive S. epidermidis and S. aureus strains for 24 h. The grafts were washed and vortexed in saline. The saline was passaged to blood agar and incubated for 24 h. The colonies were counted. Naive and incubated graft materials were examined by scanning electron microscopy to reveal both textile properties and biofilm formation. Physicochemical properties were evaluated. Wilcoxon signed ranks test and Friedman test were used for statistical analysis. Results. S. epidermidis showed a significantly decreased adherence to monofilament polypropylene graft, and increased adherence to multifilament polypropylene graft (P<0.05). S. aureus showed a significant affinity for monofilament composite graft (P<0.05). SEM studies showed that biofilm formation was present on multifilament polypropylene graft. Conclusions. Both S. epidermidis and S. aureus had significantly less adherence to multifilament lightweight composite than multifilament polypropylene graft. S. epidermidis showed a greater affinity to monofilament composite graft compared with monofilament polypropylene graft. Overall S. epidermidis adherence for multifilament lightweight composite and monofilament composite was less than multifilament polypropylene and higher than monofilament polypropylene. S. epidermidis and S. aureus showed different adherence for each graft. Changes in material composition and textile properties may well influence bacterial adherence. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:E79 / E86
页数:8
相关论文
共 23 条
[1]   A rat model of polypropylene graft infection caused by Staphylococcus epidermidis [J].
Agalar, C ;
Ozdogan, M ;
Agalar, F ;
Saygun, O ;
Aydinuraz, K ;
Akkus, A ;
Çeken, S ;
Akturk, S .
ANZ JOURNAL OF SURGERY, 2006, 76 (05) :387-391
[2]  
An YH, 1998, J BIOMED MATER RES, V43, P338, DOI 10.1002/(SICI)1097-4636(199823)43:3<338::AID-JBM16>3.0.CO
[3]  
2-B
[4]   In vitro interaction of bacteria with polypropylene/ePTFE prostheses [J].
Bellón, JM ;
G-Honduvilla, N ;
Jurado, F ;
G-Carranza, A ;
Buján, J .
BIOMATERIALS, 2001, 22 (14) :2021-2024
[5]   Residence time dependent desorption of Staphylococcus epidermidis from hydrophobic and hydrophilic substrata [J].
Boks, Niels P. ;
Kaper, Hans J. ;
Norde, Willem ;
Busscher, Henk J. ;
van der Mei, Henny C. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 67 (02) :276-278
[6]   Evaluation of new prosthetic meshes for ventral hernia repair [J].
Burger, J. W. A. ;
Halm, J. A. ;
Wijsmuller, A. R. ;
ten Raa, S. ;
Jeekel, J. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (08) :1320-1325
[7]  
Catalanotti P, 2005, NEW MICROBIOL, V28, P345
[8]   Affinity of Staphylococcus epidermidis to various prosthetic graft materials [J].
Demirer, S ;
Geçim, IE ;
Aydinuraz, K ;
Ataoglu, H ;
Yerdel, MA ;
Kuterdem, E .
JOURNAL OF SURGICAL RESEARCH, 2001, 99 (01) :70-74
[9]  
DENHARTOD G, 2008, COCHRANE DB SYST REV, V3
[10]   Polymer surface properties and their effect on the adhesion of Proteus mirabilis [J].
Downer, A ;
Morris, N ;
Feast, WJ ;
Stickler, D .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2003, 217 (H4) :279-289