The potential for office buildings with mixed-mode ventilation and low energy cooling systems in arid climates

被引:77
作者
Ezzeldin, Sherif [1 ]
Rees, Simon J. [2 ]
机构
[1] Arab Acad Sci & Technol & Maritime Transport, Dept Architectural Engn & Environm Design, Cairo, Egypt
[2] De Montfort Univ, Inst Energy & Sustainable Dev, Leicester LE1 9BH, Leics, England
关键词
Mixed-mode ventilation; Cooling strategies; Office buildings; Thermal comfort; Energy savings; Arid climates; THERMAL COMFORT; DESIGN;
D O I
10.1016/j.enbuild.2013.06.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The application of hybrid or mixed-mode ventilation in severe arid climates and its integration with other passive cooling strategies is very challenging. This paper presents a systematic evaluation of the performance of various mixed-mode cooling strategies for office buildings with different levels of internal heat gain operated in four cities representative of arid climates. The results of simulations made with EnergyPlus are evaluated in terms of appropriate thermal comfort criteria and subsequently potential reductions in plant energy consumption so that the most effective strategies to mitigate the energy consumption associated with air-conditioning processes. The results show that hybrid approaches to maintaining indoor environmental conditions have the potential to save approximately half of the plant energy consumption compared to common active air-conditioning systems. Savings in plant energy due to the application of mixed-mode strategies that include low energy cooling technologies such as radiant, evaporative and ground-coupled cooling could exceed 90%. We conclude that mixed-mode cooling strategies should be able to provide satisfactory indoor environments and can result in highly efficient office building designs and so should be considered for application in arid climates. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:368 / 381
页数:14
相关论文
共 47 条
[1]  
[Anonymous], 1997, RP884 ASHRAE INC
[2]  
ASHRAE, 2005, ASHRAE HDB FUND 2005
[3]  
ASHRAE, 2004, 9012004 ASHRAE INC
[4]  
ASHRAE, 2004, 552004 ASHRAE
[5]  
Axley J W., 2002, ASHRAE Transactions, V108, P1260
[6]   Comfort standards and variations in exceedance for mixed-mode buildings [J].
Borgeson, Sam ;
Brager, Gail .
BUILDING RESEARCH AND INFORMATION, 2011, 39 (02) :118-133
[7]  
Brager G.S., 2007, SUMMARY REPORT CONTR
[8]   Occupant satisfaction in mixed-mode buildings [J].
Brager, Gail ;
Baker, Lindsay .
BUILDING RESEARCH AND INFORMATION, 2009, 37 (04) :369-380
[9]  
Brager GS, 2006, ASHRAE J, V48, P30
[10]  
Briggs R., 2002, ASHRAE T, V109, P109