Efficacy and effectiveness of alcohol in the disinfection of semi-critical materials: a systematic review

被引:25
作者
Ribeiro, Maira Marques [1 ]
Neumann, Verena Ashley [1 ]
Padoveze, Maria Clara [1 ]
Graziano, Kazuko Uchikawa [1 ]
机构
[1] Univ Sao Paulo, Escola Enfermagem, BR-05403000 Sao Paulo, SP, Brazil
关键词
Ethanol; Disinfection; Decontamination; Efficacy; Effectiveness;
D O I
10.1590/0104-1169.0266.2611
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: to assess the efficacy and the effectiveness of 60-80% alcohol (v/v) in the disinfection of semi-critical materials which were either previously cleaned or not. Method: studies obtained from BIREME, IBECS, MEDLINE, ScIELO, PubMed, Ask Medline web portals, and references from other studies. Criteria were created to assess the methodological quality of articles. Out of the 906 studies found, 14 have been included. Results: after materials were disinfected with alcohol, microorganisms were detected in 104/282 (36.9%) effectiveness tests and in 23/92 (25.0%) efficacy tests that were conducted. In the field studies, disinfection was not achieved for 74/218 (33.9%) of the products that were submitted to previous cleaning and for 30/64 (46.9%) of the ones which were not submitted to previous cleaning. In the experimental studies, alcohol disinfection was not efficacy in 11/30 (36.7%) and 12/62 (19.4%) of products, respectively. The studies were not found to have followed standardized methods. Conclusion: disinfection of semi-critical products with alcohol 70% - or in an approximate concentration - cannot be recommended to all health care products in an unrestricted way. However, according to the type of semi-critical product, disinfection can be attained with or without previous cleaning.
引用
收藏
页码:741 / 752
页数:12
相关论文
共 22 条
[1]  
Almeida CMF, 2012, DENTAL PRESS J ORTHO, V17, P105
[2]   Microbiologic assessment of disposable sterile endoscopic sheaths to replace high-level disinfection in reprocessing: A prospective clinical trial with nasopharygoscopes [J].
Alvarado, Carla J. ;
Anderson, Ashley G. ;
Maki, Dennis G. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2009, 37 (05) :408-413
[3]  
[Anonymous], 2000, CONT FORM PREM NOT 5
[4]  
[Anonymous], 2008, GUID DISINF STER HLT
[5]  
Baldissera EZ, 2006, REV ODONTO CIENC, V21, P153
[6]  
Baldissera EZ, 2002, REV FAC ODONTOL, V43, P15
[7]   Disinfection of Flexible Fiberoptic Laryngoscopes After In Vitro Contamination With Staphylococcus aureus and Candida albicans [J].
Chang, Dennis ;
Florea, Andrew ;
Rowe, Mark ;
Seiberling, Kristin A. .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2012, 138 (02) :119-121
[8]  
CRAVEN ER, 1987, OPHTHALMOLOGY, V94, P1538
[9]   Efficacy of high-level disinfectants for reprocessing GI endoscopes in simulated-use testing [J].
Foliente, RL ;
Kovacs, BJ ;
Aprecio, RM ;
Bains, HJ ;
Kettering, JD ;
Chen, YK .
GASTROINTESTINAL ENDOSCOPY, 2001, 53 (04) :456-462
[10]  
Galvão Cristina Maria, 2004, Rev. Latino-Am. Enfermagem, V12, P549, DOI 10.1590/S0104-11692004000300014