Determination of paraquat in waters by enzymatic inhibition using flow-injection analysis

被引:2
作者
Lopez-Erroz, C [1 ]
Viñas, P [1 ]
Campillo, N [1 ]
Hernandez-Cordoba, M [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
flow injection; paraquat; acetylthiocholine; acetylcholinesterase waters;
D O I
10.1080/03067319808035898
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection method based on the inhibition of the hydrolysis of acetylthiocholine to thiocholine catalyzed by acetylcholinesterase is proposed for the determination of the herbicide paraquat. The liberated thiocholine is monitored spectrophotometrically using 5,5'-dithiobis(2-nitrobenzoic acid). The calibration graph based on peak area is linear in the range 0.2-1.5 mu g/ml with a relative standard deviation of +/-4.1 % The method is applied to the determination of paraquat in a commercial product and in several water samples.
引用
收藏
页码:267 / 274
页数:8
相关论文
共 17 条
[1]   AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF PARAQUAT AT THE SUBNANOGRAM PER MILLILITER LEVEL [J].
AGUDO, M ;
RIOS, A ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1993, 281 (01) :103-109
[2]   CATHODIC STRIPPING VOLTAMMETRY OF PARAQUAT ON A CARBON PASTE ELECTRODE ELECTRODE MODIFIED WITH AMBERLITE XAD-2 RESIN [J].
ALVAREZ, E ;
SEVILLA, MT ;
PINILLA, JM ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1992, 260 (01) :19-23
[3]   DETERMINATION OF PARAQUAT IN RAT-BRAIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CORASANITI, MT ;
NISTICO, G .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :419-425
[4]   A NEW AND RAPID COLORIMETRIC DETERMINATION OF ACETYLCHOLINESTERASE ACTIVITY [J].
ELLMAN, GL ;
COURTNEY, KD ;
ANDRES, V ;
FEATHERSTONE, RM .
BIOCHEMICAL PHARMACOLOGY, 1961, 7 (02) :88-&
[5]   A SEMIAUTOMATED FLOW-INJECTION PROCEDURE FOR ACETYLCHOLINESTERASE AND CHOLINESTERASE ACTIVITIES [J].
GARCIA, IL ;
ABELLAN, FR ;
CORDOBA, MH .
ANALYTICAL BIOCHEMISTRY, 1992, 200 (01) :176-179
[6]  
Holme DJ, 1993, ANAL BIOCH
[7]   On-line liquid chromatographic trace enrichment and highperformance liquid chromatographic determination of diquat, paraquat and difenzoquat in water [J].
Ibanez, M ;
Pico, Y ;
Manes, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :325-331
[8]   DETERMINATION OF DIQUAT AND PARAQUAT IN WATER USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CONFIRMATION BY LIQUID-CHROMATOGRAPHY PARTICLE-BEAM MASS-SPECTROMETRY [J].
KAMBHAMPATI, I ;
ROINESTAD, KS ;
HARTMAN, TG ;
ROSEN, JD ;
FUKUDA, EK ;
LIPPINCOTT, RL ;
ROSEN, RT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) :67-73
[9]   EXCHANGEABLE IMMOBILIZED ENZYME REACTOR FOR ENZYME-INHIBITION TESTS IN FLOW-INJECTION ANALYSIS USING A MAGNETIC DEVICE - DETERMINATION OF PESTICIDES IN DRINKING-WATER [J].
KINDERVATER, R ;
KUNNECKE, W ;
SCHMID, RD .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :113-117
[10]  
LAINECESSAC P, 1989, CLIN CHEM, V35, P77