Effects of adjustable and stationary fans with misters on core body temperature and lying behavior of lactating dairy cows in a semiarid climate

被引:56
作者
Anderson, S. D. [1 ]
Bradford, B. J. [2 ]
Harner, J. P. [3 ]
Tucker, C. B. [4 ]
Choi, C. Y. [5 ]
Allen, J. D. [1 ]
Hall, L. W. [1 ]
Rungruang, S. [1 ]
Collier, R. J. [1 ]
Smith, J. F. [1 ]
机构
[1] Univ Arizona, Dept Anim Sci, Tucson, AZ 85721 USA
[2] Kansas State Univ, Dept Anim Sci & Ind, Manhattan, KS 66502 USA
[3] Kansas State Univ, Dept Biol & Agr Engn, Manhattan, KS 66502 USA
[4] Univ Calif Davis, Dept Anim Sci, Davis, CA 95616 USA
[5] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
关键词
heat stress; adjustable fan; body temperature; lying behavior; CATTLE-COOLING SYSTEMS; HEAT-STRESS; HOLSTEIN COWS; MILK-YIELD; SHADE; ENVIRONMENT; PARAMETERS; PHYSIOLOGY; SPRINKLERS; NUTRITION;
D O I
10.3168/jds.2012-6401
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Cows readily seek shade to reduce solar heat load during periods of high ambient temperature. Typically, auxiliary cooling systems are oriented to maximize cooling for shaded cows. However, when a shade structure is oriented north-south, stationary fan and mister cooling systems are unable to track shade as the sun's angle shifts throughout the day, and thus can become ineffective. The FlipFan Dairy Cooling System (Schaefer Ventilation Equipment, Sauk Rapids, MN) employs fans and misters that follow shade and compensate for wind speed by rotating on a horizontal axis. Multiparous, lactating Holstein cows (n = 144) on a commercial dairy in Arizona were cooled by a fixed system comprised of stationary fans and misters acting as control or the adjustable FlipFan operated for 16.5 h/d (0830 to 0100 h). Core body temperatures (CBT) of 64 cows (4 pens/treatment; 8 cows/pen; 6 d) and lying behavior of 144 cows (4 pens/treatment; 18 cows/pen; 5 d) were collected by intravaginal and leg data loggers, respectively. Cows were balanced by milk production, blocked by days in milk, and randomly assigned to pen within block. Pen was the experimental unit. In a second experiment, isothermal maps were developed using a fixed system of thermal data loggers arranged in the shaded areas of the pens at different times of day and were analyzed for differences in the temperature-humidity index (THI) achieved by each cooling treatment. Ambient conditions consisted of a mean temperature of 33.0 degrees C, mean relative humidity of 40.3%, and mean THI of 80.2. Mean 24-h CBT for FlipFan was lower than control (38.9 vs. 39.1 +/- 0.04 degrees C). A treatment x time interaction was observed in which CBT of FlipFan was 0.4 degrees C lower than control from 0600 to 0800 h and 1500 to 1600 h. Cows cooled by FlipFan spent more time lying down compared with those cooled by control (9.5 vs. 8.6 h/d). Cows under FlipFan had more frequent lying bouts than did those under control (12.8 vs. 10.7 bouts/d). Lower CBT and decreased standing time are consistent with the findings of other studies when ambient heat load was reduced. In the second experiment, the FlipFan system achieved a lower THI in the morning and evening (5.9 and 1.7%, respectively), and the THI also tended to be 0.8% lower in the afternoon compared with that of control. Results indicate that FlipFan is more effective than a stationary fan and mister system at decreasing CBT, increasing lying time and bouts, and providing a more desirable microenvironment for cows throughout the day in a semiarid environment.
引用
收藏
页码:4738 / 4750
页数:13
相关论文
共 36 条
[1]   EFFECT OF LACTATION ON DIURNAL TEMPERATURE PATTERNS OF DAIRY-CATTLE IN HOT ENVIRONMENTS [J].
ARAKI, CT ;
NAKAMURA, RM ;
KAM, LWG ;
CLARKE, N .
JOURNAL OF DAIRY SCIENCE, 1984, 67 (08) :1752-1760
[2]   SYMPOSIUM - NUTRITION AND HEAT-STRESS HEAT-STRESS INTERACTION WITH SHADE AND COOLING [J].
ARMSTRONG, DV .
JOURNAL OF DAIRY SCIENCE, 1994, 77 (07) :2044-2050
[3]   Dynamic response indicators of heat stress in shaded and non-shaded feedlot cattle, Part 1: Analyses of indicators [J].
Brown-Brandl, TM ;
Eigenberg, RA ;
Nienaber, JA ;
Hahn, GL .
BIOSYSTEMS ENGINEERING, 2005, 90 (04) :451-462
[4]  
BUFFINGTON DE, 1981, T ASAE, V24, P711, DOI 10.13031/2013.34325
[5]  
Collier R J, 2006, J Anim Sci, V84 Suppl, pE1
[6]   SHADE MANAGEMENT IN SUB-TROPICAL ENVIRONMENT FOR MILK-YIELD AND COMPOSITION IN HOLSTEIN AND JERSEY COWS [J].
COLLIER, RJ ;
ELEY, RM ;
SHARMA, AK ;
PEREIRA, RM ;
BUFFINGTON, DE .
JOURNAL OF DAIRY SCIENCE, 1981, 64 (05) :844-849
[7]   Thermoregulatory responses of Holstein and Brown Swiss Heat-Stressed dairy cows to two different cooling systems [J].
Correa-Calderon, A ;
Armstrong, D ;
Ray, D ;
DeNise, S ;
Enns, M ;
Howison, C .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2004, 48 (03) :142-148
[8]   PHYSIOLOGICAL, ENVIRONMENTAL, AND HORMONAL FACTORS AT INSEMINATION WHICH MAY AFFECT CONCEPTION [J].
GWAZDAUSKAS, FC ;
THATCHER, WW ;
WILCOX, CJ .
JOURNAL OF DAIRY SCIENCE, 1973, 56 (07) :873-877
[9]   Adverse impact of heat stress on embryo production: Causes and strategies for mitigation [J].
Hansen, PJ ;
Drost, M ;
Rivera, RM ;
Paula-Lopes, FF ;
Al-Katanani, YM ;
Krininger, CE ;
Chase, CC .
THERIOGENOLOGY, 2001, 55 (01) :91-103
[10]  
Hillman PE, 2005, T ASAE, V48, P795, DOI 10.13031/2013.18322