Radiation dose management in thoracic CT: an international survey

被引:6
作者
Molinari, Francesco [1 ,2 ]
Tack, Denis M. [3 ]
Boiselle, Philip [1 ]
Ngo, Long [1 ]
Mueller-Mang, Christina [4 ]
Litmanovich, Diana [1 ]
Bankier, Alexander A. [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Hosp Calmette, Univ Ctr Lille, Lille, France
[3] Clin Louis Caty Hop RHMS, Dept Radiol, Baudour, Belgium
[4] Med Univ Vienna, Dept Radiol, Vienna, Austria
关键词
IMAGE QUALITY; CHEST CT; COMPUTED-TOMOGRAPHY; FLEISCHNER-SOCIETY; TUBE CURRENT; LUNG-CANCER; EXPOSURE; ANGIOGRAPHY; STATEMENT; REDUCTION;
D O I
10.4261/1305-3825.DIR.6381-12.1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to examine current practice patterns of international thoracic radiologists regarding radiation dose management in adult thoracic computed tomography (CT) examinations. MATERIALS AND METHODS An electronic questionnaire was sent to 800 members of five thoracic radiology societies in North America, Europe, Asia, and Latin America addressing radiation dose training and education, standard kVp and mAs settings for thoracic CT, dose reduction practices, clinical scenarios, and demographics. RESULTS Of the 800 radiologists, 146 responded to our survey. Nearly half (66/146, 45% [95% confidence interval, 37%-53%]) had no formal training in dose reduction, with "self-study of the literature" being the most common form of training (54/146, 37% [29%-45%]). One hundred and seventeen (80% [74%-87%]) had automatic exposure control, and 76 (65% [56%-74%]) used it in all patients. Notably, most respondents (89% [84%-94%]) used a 120 to 125 kVp standard setting, whereas none used 140 kVp. The most common average dose-length-product (DLP) value was 150 to 249 mGy.cm (75/146, 51% [43%-59%]), and 59% (51%-67%) delivered less than 250 mGy. cm in a 70 kg patient. There was a tendency towards higher DLP values with multidetector-row CT. Age, gender, and pregnancy were associated more with dose reduction than weight and clinical indication. CONCLUSION Efforts for reducing patient radiation dose are highly prevalent among thoracic radiologists. Areas for improvement include reduction of default tube current settings, reduction of anatomical scan coverage, greater use of automatic exposure control, and eventually, reduction of current reference dose values. Our study emphasizes the need for international guidelines to foster greater conformity in dose reduction by thoracic radiologists.
引用
收藏
页码:201 / U156
页数:9
相关论文
共 23 条
[1]   Air trapping: Comparison of standard-dose and simulated low-dose thin-section CT techniques [J].
Bankier, Alexander A. ;
Schaefer-Prokop, Cornelia ;
De Maertelaer, Viviane ;
Tack, Denis ;
Jaksch, Peter ;
Klepetko, Walter ;
Gevenois, Pierre Alain .
RADIOLOGY, 2007, 242 (03) :898-906
[2]   Sequential Versus Volumetric Computed Tomography in the Follow-up of Chronic Bronchopulmonary Diseases Comparison of Diagnostic Information and Radiation Dose in 63 Adults [J].
Bendaoud, Sofiane ;
Remy-Jardin, Martine ;
Wallaert, Benoit ;
Deken, Valerie ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Remy, Jacques .
JOURNAL OF THORACIC IMAGING, 2011, 26 (03) :190-195
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[5]   Response rates and response bias for 50 surveys of pediatricians [J].
Cull, WL ;
O'Connor, KG ;
Sharp, S ;
Tang, SFS .
HEALTH SERVICES RESEARCH, 2005, 40 (01) :213-226
[6]   Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583
[7]   Further reduction of radiation dose in helical CT for lung cancer screening using small tube current and a newly designed filter [J].
Itoh, S ;
Koyama, S ;
Ikeda, M ;
Ozaki, M ;
Sawaki, A ;
Iwano, S ;
Ishigaki, T .
JOURNAL OF THORACIC IMAGING, 2001, 16 (02) :81-88
[8]   Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure Control [J].
Kalra, Mannudeep K. ;
Naz, Nausheen ;
Rizzo, Stefania M. R. ;
Blake, Michael A. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2005, 34 (05) :171-181
[9]   Techniques and applications of automatic tube current modulation for CT [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Schmidt, B ;
Westerman, BL ;
Morgan, HT ;
Saini, S .
RADIOLOGY, 2004, 233 (03) :649-657
[10]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628