Adsorptive stripping differential pulse voltammetric determination of mebendazole at a graphene nanosheets and carbon nanospheres/chitosan modified glassy carbon electrode

被引:38
作者
Ghalkhani, Masoumeh [1 ]
Shahrokhian, Saeed [2 ,3 ]
机构
[1] Shahid Rajaee Teacher Training Univ, Dept Chem, Fac Sci, Tehran, Iran
[2] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[3] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
关键词
Mebendazole; Graphene; Carbon nanospheres; Chitosan; Modified electrode; LIQUID-CHROMATOGRAPHY; BENZIMIDAZOLE RESIDUES; MASS-SPECTROMETRY; HYDROGEN-PEROXIDE; METABOLITES; REDUCTION; MUSCLE; DRUGS; OXIDE;
D O I
10.1016/j.snb.2013.05.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time graphene nanosheets and carbon nanospheres/chitosan (GNS-CNS/CS) based nanocomposite film modified electrode was used for the electro-oxidation of mebendazole (MD). MD is a benzimidazole drug that is used to treat human infections caused by parasitic worms. MD causes slow immobilization and death of the worms by selectively and irreversibly blocking uptake of glucose. The electrochemical behavior of MD at GNS-CNS/CS modified glassy carbon electrode has been investigated using cyclic and differential pulse voltammetry in aqueous media at different pHs. The prepared electrode showed an excellent electrochemical activity toward the electro-oxidation of MD leading to a significant improvement in sensitivity as compared to the bare glassy carbon electrode. The adsorptive stripping differential pulse voltammetry was used as an efficient method for the electroanalytical determination of MD. Under the optimal conditions, the modified electrode showed a wide linear response to the concentration of MD in the range of 0.02-1 mu M with a low detection limit (10.5 nM). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 33 条
  • [1] 2 HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATIONS FOR MEBENDAZOLE AND ITS METABOLITES IN HUMAN-PLASMA USING A RAPID SEP PAK C18 EXTRACTION
    ALLAN, RJ
    GOODMAN, HT
    WATSON, TR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1980, 183 (03): : 311 - 319
  • [2] [Anonymous], 2011, ANGEW CHEM
  • [3] Simultaneous determination of mebendazole and pyrantel pamoate from tablets by high performance liquid chromatography reverse phase (RP-HPLC)
    Argekar, AP
    Raj, SV
    Kapadia, SU
    [J]. TALANTA, 1997, 44 (11) : 1959 - 1965
  • [4] Determination of benzimidazole residues using liquid chromatography and tandem mass spectrometry
    Balizs, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2): : 167 - 177
  • [5] Graphene oxide gives rise to unique and intriguing voltammetry
    Brownson, Dale A. C.
    Lacombe, Alexandre C.
    Gomez-Mingot, Maria
    Banks, Craig E.
    [J]. RSC ADVANCES, 2012, 2 (02): : 665 - 668
  • [6] One-step catalyst-free generation of carbon nanospheres via laser-induced pyrolysis of anthracene
    Bystrzejewski, M.
    Lange, H.
    Huczko, A.
    Baranowski, P.
    Huebers, H.-W.
    Gemming, T.
    Pichler, T.
    Buechner, B.
    Ruemmeli, M. H.
    [J]. JOURNAL OF SOLID STATE CHEMISTRY, 2008, 181 (10) : 2796 - 2803
  • [7] Structure of a 1:1 complex between the anthelmintic drug mebendazole and propionic acid
    Caira, MR
    Dekker, TG
    Liebenberg, W
    [J]. JOURNAL OF CHEMICAL CRYSTALLOGRAPHY, 1998, 28 (01) : 11 - 15
  • [8] Determination of mebendazole in urine by cathodic stripping voltammetry
    Conesa, AJ
    Pinilla, JM
    Hernandez, L
    [J]. ANALYTICA CHIMICA ACTA, 1996, 331 (1-2) : 111 - 116
  • [9] IN-VITRO SUSCEPTIBILITY OF THE OPPORTUNISTIC FUNGUS CRYPTOCOCCUS-NEOFORMANS TO ANTHELMINTIC BENZIMIDAZOLES
    CRUZ, MC
    BARTLETT, MS
    EDLIND, TD
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1994, 38 (02) : 378 - 380
  • [10] De Ruyck H, 2003, ANAL CHIM ACTA, V483, P111, DOI 10.1016/S0003-2670(02)01018-8