On Using a Simplified Model for Leak Detection Improving in Fluid Filled Pipelines

被引:0
|
作者
Daneti, Marllene [1 ]
机构
[1] Politehn Univ Timisoara, Fac Elect & Commun, Dept Appl Elect, Timisoara 300233, Romania
来源
2010 IEEE CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION (ETFA) | 2010年
关键词
TIME-DELAY; FLOW;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A major difficulty of the acoustic techniques for pipeline leak detection and location is the small signal-to-noise ratio (SNR) of the received data, due to a wide range of perturbing factors. In order to choose the optimum method is necessary a good understanding of the given system. This paper uses a simplified pipeline model, analog with a transmission line, as a tool for simulating the acoustic signals, in order to study and develop an improved method for leak locating in a multipath and a correlated noise environment. It is shown that the results obtained by averaging the output of different algorithms, parallel implemented, lead to an improved overall robust behavior. Also, the effect of the pipeline end opening is studied. An improved accuracy is found when the opening is brought near to a matched output load impedance.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Stochastic model of material balance for leak detection in oil pipelines
    Chionov, Anton M.
    Amerkhanov, Artur A.
    Kudritsky, Andrey, V
    NAUKA I TEHNOLOGII TRUBOPROVODNOGO TRANSPORTA NEFTI I NEFTEPRODUKTOV-SCIENCE & TECHNOLOGIES-OIL AND OIL PRODUCTS PIPELINE TRANSPORTATION, 2019, 9 (06): : 633 - 639
  • [22] Leak Detection for Self-Contained Fluid-Filled Cables using Regression Analysis
    Hao, L.
    Lewin, P. L.
    Swingler, S. G.
    Bradley, C.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [23] Simplified Ultrasonic Damage Detection in Fluid-Filled Pipes
    Bouko Vogelaar
    Michael Golombok
    Journal of Nondestructive Evaluation, 2017, 36
  • [24] Simplified Ultrasonic Damage Detection in Fluid-Filled Pipes
    Vogelaar, Bouko
    Golombok, Michael
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2017, 36 (04)
  • [25] Leak Detection in Gas Pipelines Using Accurate Hydraulic Models
    Bagajewicz, Miguel
    Valtinson, Gary
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (44) : 16964 - 16972
  • [26] Leak detection in long pipelines using the least squares method
    Al-Khomairi, Abdulrahman
    JOURNAL OF HYDRAULIC RESEARCH, 2008, 46 (03) : 392 - 401
  • [27] Probabilistic leak detection in pipelines using the mass imbalance approach
    Rougier, J
    JOURNAL OF HYDRAULIC RESEARCH, 2005, 43 (05) : 556 - 566
  • [28] Leak detection for oil pipelines by using the extended Kalman filter
    Xiao Gao-qing
    Wu Ming
    Qi Wei
    Proceedings of 2004 Chinese Control and Decision Conference, 2004, : 605 - +
  • [29] Leak location in fluid filled cables using the PFT method
    Consolidated Edison Co of New York, New York, NY, United States
    IEEE Trans Power Delivery, 1 (18-22):
  • [30] Leak location in fluid filled cables using the PFT method
    Ghafurian, R
    Dietz, RN
    Rodenbaugh, T
    Dominguez, J
    Tai, N
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (01) : 18 - 22