Attractive Zone of Lightning Rods Evaluated with a Leader Progression Model in a Common Building in Brazil

被引:0
作者
Lobato, Andre [1 ]
Cooray, Vernon [1 ]
Arevalo, Liliana [2 ]
机构
[1] Uppsala Univ, Div Elect, Uppsala, Sweden
[2] ABB Power Grids HVDC, R&D Dept, Ludvika, Sweden
来源
2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA) | 2017年
关键词
leader progression model; lightning protection; lightning rod; finite element method; LONG AIR-GAPS; STRIKING DISTANCE; TRANSMISSION-LINES; PROPAGATION MODEL; SELF-CONSISTENT; POSITIVE-SPARK; INCEPTION; SIMULATION; FLASHES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modeling the lightning attachment process is required on any method to design the air-termination elements of a lightning protection system. An attachment model that adopts the leader progression concept is used to evaluate the three-dimensional attractive zone of a lightning rod on a common 54-m tall building in Sao Paulo, Brazil. Electric field and scalar potential distributions are calculated numerically with a finite element method. The result is compared with the interception volume predicted by the electro-geometric model, as applied by the rolling sphere method. The results show that the electrogeometric theory underestimates the striking distance and the attractive radius. Moreover, in the presence of upward connecting leaders, the striking distance varies according to the field enhancement on the geometry of the structure and the lateral displacement of the stepped leader. The simulated propagated distances and speeds of the downward and upward leaders are compared with a recently published high-speed video analysis of a natural lightning attachment case observed on the evaluated lightning rod. A reasonable agreement between the simulated and measured leader characteristics has been found.
引用
收藏
页码:380 / 388
页数:9
相关论文
共 37 条
  • [1] [Anonymous], 2010, 623053 IEC, Vsecond
  • [2] [Anonymous], 2010, Standard IEC 62305-1
  • [3] [Anonymous], 2013, 9982012 IEEE
  • [4] Arevalo L, 2009, 10 INT S LIGHTN PROT
  • [5] Arevalo L., 2016, 33 INT C LIGHTN PROT
  • [6] On the interception of lightning flashes by power transmission lines
    Arevalo, Liliana
    Cooray, Vernon
    [J]. JOURNAL OF ELECTROSTATICS, 2011, 69 (03) : 220 - 227
  • [7] 'The mesh method' in lightning protection standards - Revisited
    Arevalo, Liliana
    Cooray, Vernon
    [J]. JOURNAL OF ELECTROSTATICS, 2010, 68 (04) : 311 - 314
  • [8] Lightning striking distance of complex structures
    Becerra, M.
    Cooray, V.
    Roman, F.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (01) : 131 - 138
  • [9] A simplified physical model to determine the lightning upward connecting leader inception
    Becerra, M
    Cooray, V
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 897 - 908
  • [10] On the velocity of positive connecting leaders associated with negative downward lightning leaders
    Becerra, M.
    Cooray, V.
    [J]. GEOPHYSICAL RESEARCH LETTERS, 2008, 35 (02)