Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction

被引:81
作者
Hansen, Michael S. [1 ]
Sorensen, Thomas S. [2 ,3 ]
Arai, Andrew E. [1 ]
Kellman, Peter [1 ]
机构
[1] NHLBI, NIH, Bethesda, MD 20814 USA
[2] Aarhus Univ, Dept Comp Sci, DK-8000 Aarhus, Denmark
[3] Aarhus Univ, Inst Clin Med, DK-8000 Aarhus, Denmark
基金
美国国家卫生研究院;
关键词
real-time MRI; parallel MRI; nonrigid motion connection; myocardial function; non-Cartesian MRI; COMMODITY GRAPHICS HARDWARE; LEFT-VENTRICULAR FUNCTION; K-T SENSE; RAPID EVALUATION; OPTICAL-FLOW; BREATH-HOLD; REGISTRATION; ENHANCEMENT; HEART; MASS;
D O I
10.1002/mrm.23284
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac function has traditionally been evaluated using breath-hold cine acquisitions. However, there is a great need for free breathing techniques in patients who have difficulty in holding their breath. Real-time cardiac MRI is a valuable alternative to the traditional breath-hold imaging approach, but the real-time images are often inferior in spatial and temporal resolution. This article presents a general method for reconstruction of high spatial and temporal resolution cine images from a real-time acquisition acquired over multiple cardiac cycles. The method combines parallel imaging and motion correction based on nonrigid registration and can be applied to arbitrary k-space trajectories. The method is demonstrated with real-time Cartesian imaging and Golden Angle radial acquisitions, and the motion-corrected acquisitions are compared with raw real-time images and breath-hold cine acquisitions in 10 (N = 10) subjects. Acceptable image quality was obtained in all motion-corrected reconstructions, and the resulting mean image quality score was (a) Cartesian real-time: 2.48, (b) Golden Angle real-time: 1.90 (1.002.50), (c) Cartesian motion correction: 3.92, (d) Radial motion correction: 4.58, and (e) Breath-hold cine: 5.00. The proposed method provides a flexible way to obtain high-quality, high-resolution cine images in patients with difficulty holding their breath. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:741 / 750
页数:10
相关论文
共 25 条
[1]  
[Anonymous], 1996, Iterative Solution Methods
[2]   Matrix description of general motion correction applied to multishot images [J].
Batchelor, PG ;
Atkinson, D ;
Irarrazaval, P ;
Hill, DLG ;
Hajnal, J ;
Larkman, D .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1273-1280
[3]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[4]   Using cardiac phase to order reconstruction [CAPTOR]: A method to improve diastolic images [J].
Feinstein, JA ;
Epstein, FH ;
Arai, AE ;
Foo, TKF ;
Hartley, MR ;
Balaban, RS ;
Wolff, SD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :794-798
[5]   Cartesian SENSE and k-t SENSE reconstruction using commodity graphics hardware [J].
Hansen, Michael S. ;
Atkinson, David ;
Sorensen, Thomas S. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :463-468
[6]   Rapid evaluation of right and left ventricular function and mass using real-time True-FISP Cine MR imaging without breath-hold: Comparison with segmented True-FISP Cine MR imaging with breath-hold [J].
Hori, Y ;
Yamada, N ;
Higashi, M ;
Hirai, N ;
Nakatani, S .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (03) :439-450
[7]   DETERMINING OPTICAL-FLOW [J].
HORN, BKP ;
SCHUNCK, BG .
ARTIFICIAL INTELLIGENCE, 1981, 17 (1-3) :185-203
[8]   SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING [J].
JACKSON, JI ;
MEYER, CH ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :473-478
[9]   Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system [J].
Kaji, S ;
Yang, PC ;
Kerr, AB ;
Tang, WHW ;
Meyer, CH ;
Macovski, A ;
Pauly, JM ;
Nishimura, DG ;
Hu, BS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (02) :527-533
[10]   Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) [J].
Kellman, P ;
Epstein, FH ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :846-852