Water-soluble mercury ion sensing based on the thymine-Hg2+-thymine base pair using retroreflective Janus particle as an optical signaling probe

被引:55
作者
Chun, Hyeong Jin [1 ]
Kim, Saemi [1 ]
Han, Yong Duk [1 ]
Kim, Dong Woo [1 ]
Kim, Ka Ram [1 ]
Kim, Hyo-Sop [1 ]
Kim, Jae-Ho [1 ]
Yoon, Hyun C. [1 ]
机构
[1] Ajou Univ, Dept Mol Sci & Technol, Suwon 443749, South Korea
基金
新加坡国家研究基金会;
关键词
Mercury ion sensing; Retroreflective Janus particles; Optical biosensor; Hg2+-mediated thymine- thymine base pairing; Stem-loop DNA probe; HYBRIDIZATION CHAIN-REACTIONS; MOLECULAR BEACON; HIGH-SENSITIVITY; RAPID DETECTION; HG2+ DETECTION; AQUEOUS-MEDIA; DNA; SENSOR; FLUORESCENCE; PLATFORM;
D O I
10.1016/j.bios.2018.01.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Herein, we report an optical sensing platform for mercury ions (Hg2+) in water based on the integration of Hg2+-mediated thymine-thymine (T-T) stabilization, a biotinylated stem-loop DNA probe, and a streptavidin-modified retroreflective Janus particle (SA-RJP). Two oligonucleotide probes, including a stem-loop DNA probe and an assistant DNA probe, were utilized. In the absence of Hg2+, the assistant DNA probe does not hybridize with the stem-loop probe due to their T-T mismatch, so the surface-immobilized stem-loop DNA probe remains a closed hairpin structure. In the presence of Hg2+, the DNA forms a double-stranded structure with the loop region via Hg2+-mediated T-T stabilization. This DNA hybridization induces stretching of the stem-loop DNA probe, exposing biotin. To translate these Hg2+-mediated structural changes in DNA probe into measurable signal, SA-RJP, an optical signaling label, is applied to recognize the exposed biotin. The number of biospecifically bound SA-RJPs is proportional to the concentration of Hg2+, so that the concentration of Hg2+ can be quantitatively analyzed by counting the number of RIPs. Using the system, a highly selective and sensitive measurement of Hg2+ was accomplished with a limit of detection of 0.027 nM. Considering the simplified optical instrumentation required for retroreflection-based RJP counting, RJP-assisted Hg2+ measurement can be accomplished in a much easier and inexpensive manner. Moreover, the detection of Hg2+ in real drinking water samples including tap and commercial bottled water was successfully carried out.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 46 条
[1]  
Armbruster David A, 2008, Clin Biochem Rev, V29 Suppl 1, pS49
[2]   DETERMINATION OF VOLATILE MERCURY SPECIES AT THE PICOGRAM LEVEL BY LOW-TEMPERATURE GAS-CHROMATOGRAPHY WITH COLD-VAPOR ATOMIC FLUORESCENCE DETECTION [J].
BLOOM, N ;
FITZGERALD, WF .
ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) :151-161
[3]  
EPA (United States), 2001, EPA823F01011
[4]   On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry [J].
Ferrua, N. ;
Cerutti, S. ;
Salonia, J. A. ;
Olsina, R. A. ;
Martinez, L. D. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 141 (03) :693-699
[5]   Determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry [J].
Fong, Bonnie Mei Wah ;
Siu, Tak Shing ;
Lee, Joseph Sai Kit ;
Tam, Sidney .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (05) :281-287
[6]   Microretroreflector-Sedimentation Immunoassays for Pathogen Detection [J].
Garvey, Gavin ;
Shakarisaz, David ;
Ruiz-Ruiz, Federico ;
Hagstroem, Anna E. V. ;
Raja, Balakrishnan ;
Pascente, Carmen ;
Kar, Archana ;
Kourentzi, Katerina ;
Rito-Palomares, Marco ;
Ruchhoeft, Paul ;
Willson, Richard C. .
ANALYTICAL CHEMISTRY, 2014, 86 (18) :9029-9035
[7]   Retroreflective Janus Microparticle as a Nonspectroscopic Optical Immunosensing Probe [J].
Han, Yong Duk ;
Kim, Hyo-Sop ;
Park, Yoo Min ;
Chun, Hyeong Jin ;
Kim, Jae-Ho ;
Yoon, Hyun C. .
ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (17) :10767-10774
[8]   Engineering a unimolecular multifunctional DNA probe for analysis of Hg2+ and Ag+ [J].
He, Xiaoxiao ;
Qing, Zhihe ;
Wang, Kemin ;
Zou, Zhen ;
Shi, Hui ;
Huang, Jin .
ANALYTICAL METHODS, 2012, 4 (02) :345-347
[9]   A thymidine-terminated molecular beacon for selective Hg2+ or sequence-specific DNA assay [J].
Hou, Peng ;
Long, Yunfei ;
Zhao, Jin ;
Wang, Jianxiu ;
Zhou, Feimeng .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 86 :76-79
[10]   Graphene Oxide-Based Amplified Fluorescent Biosensor for Hg2+ Detection through Hybridization Chain Reactions [J].
Huang, Jiahao ;
Gao, Xiang ;
Jia, Jingjing ;
Kim, Jang-Kyo ;
Li, Zhigang .
ANALYTICAL CHEMISTRY, 2014, 86 (06) :3209-3215