High-Voltage Bias Testing of PV Modules in the Hot and Humid Climate without Inducing Irreversible Instantaneous Degradation

被引:0
|
作者
Dhere, Neelkanth [1 ]
Kaul, Ashwani [1 ]
Schneller, Eric [1 ]
Shiradkar, Narendra [1 ]
机构
[1] Florida Solar Energy Ctr, Cocoa, FL 32922 USA
来源
2012 38TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC) | 2012年
关键词
High-voltage bias testing; reliability; outdoor testing; PV; c-Si;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
High-voltage bias testing of PV modules is known to be useful for revealing design, material and process flaws in PV modules. It is accepted that the hot and humid climate under high-voltage bias imposes a severely harsh environment on the PV modules and enhances the possibility of degradation. Test location is, therefore, important. A test methodology is being presented here that can provide useful information for testing PV modules at high voltage in nature's own laboratory in a relatively short time frame.
引用
收藏
页码:2445 / 2448
页数:4
相关论文
共 7 条
  • [1] Methods for High-Voltage Bias Testing of PV modules in Hot and Humid Climate
    Dhere, Neelkanth G.
    Pethe, Shirish A.
    Kaul, Ashwani
    RELIABILITY OF PHOTOVOLTAIC CELLS, MODULES, COMPONENTS, AND SYSTEMS IV, 2011, 8112
  • [2] High-voltage bias testing of thin-film PV modules
    Dhere, NG
    Bet, SM
    Patil, HP
    PROCEEDINGS OF 3RD WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION, VOLS A-C, 2003, : 1923 - 1926
  • [3] Performance degradation analysis of high-voltage biased thin-film PV modules in hot and humid conditions
    Dhere, NG
    Hadagali, VV
    Jansen, K
    Conference Record of the Thirty-First IEEE Photovoltaic Specialists Conference - 2005, 2005, : 507 - 510
  • [4] Outdoor Performance Testing of Thin-Film PV Modules in the Hot and Humid Climate
    Dhere, Neelkanth G.
    Kaul, Ashwani
    Pethe, Shirish A.
    Schneller, Eric
    Shiradkar, Narendra S.
    2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 2994 - 2997
  • [5] Understanding interfacial chemistry of positive bias high-voltage degradation in photovoltaic modules
    Sinha, Archana
    Moffitt, Stephanie L.
    Hurst, Katherine
    Kempe, Michael
    Han, Katherine
    Shen, Yu-Chen
    Miller, David C.
    Hacke, Peter
    Schelhas, Laura T.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2021, 223
  • [6] Evolution of Leakage Current Paths in MC-Si PV Modules From Leading Manufacturers Undergoing High-Voltage Bias Testing
    Dhere, Neelkanth G.
    Shiradkar, Narendra S.
    Schneller, Eric
    IEEE JOURNAL OF PHOTOVOLTAICS, 2014, 4 (02): : 654 - 658
  • [7] The Influence of the EVA Film Aging on the Degradation Behavior of PV Modules Under High Voltage Bias in Wet Conditions Followed by Electroluminescence
    Brecl, Kristijan
    Barretta, Chiara
    Oreski, Gernot
    Malic, Barbara
    Topic, Marko
    IEEE JOURNAL OF PHOTOVOLTAICS, 2019, 9 (01): : 259 - 265