Mass preserving image registration for lung CT

被引:60
作者
Gorbunova, Vladlena [1 ]
Sporring, Jon [1 ]
Lo, Pechin [1 ]
Loeve, Martine [2 ]
Tiddens, Harm A. [2 ]
Nielsen, Mads [1 ,3 ]
Dirksen, Asger [4 ]
de Bruijne, Marleen [1 ,5 ]
机构
[1] Univ Copenhagen, Dept Comp Sci, Image Grp, DK-1168 Copenhagen, Denmark
[2] Erasmus MC, Dept Pediat Pulmonol & Allergol & Radiol, Rotterdam, Netherlands
[3] Nord Biosci AS, As, Denmark
[4] Gentofte Univ Hosp, Dept Resp Med, Gentofte, Denmark
[5] Erasmus MC, Dept Radiol & Med Informat, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
关键词
Image registration; B-Splines; Mass preservation; Lung CT; DEFORMABLE REGISTRATION; NONRIGID REGISTRATION; COMPUTED-TOMOGRAPHY; MOTION; SEGMENTATION; SIMULATION; CHEST;
D O I
10.1016/j.media.2011.11.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents a mass preserving image registration algorithm for lung a images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated into a standard image registration framework with a composition of a global affine and several free-form B-Spline transformations with increasing grid resolution. The proposed mass preserving registration method is compared to registration using the sum of squared intensity differences as a similarity function on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant difference between the two methods in the first group. Target registration error, assessed via a set of manually annotated landmarks in the last group, was significantly smaller for the proposed registration method. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:786 / 795
页数:10
相关论文
共 44 条
[1]   Landmark detection in the chest and registration of lung surfaces with an application to nodule registration [J].
Betke, M ;
Hong, H ;
Thomas, D ;
Prince, C ;
Ko, JP .
MEDICAL IMAGE ANALYSIS, 2003, 7 (03) :265-281
[2]   4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis [J].
Boldea, Vlad ;
Sharp, Gregory C. ;
Jiang, Steve B. ;
Sarrut, David .
MEDICAL PHYSICS, 2008, 35 (03) :1008-1018
[3]  
Castillo E, 2009, J MED BIOL ENG, V29, P222
[4]   A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets [J].
Castillo, Richard ;
Castillo, Edward ;
Guerra, Rudy ;
Johnson, Valen E. ;
McPhail, Travis ;
Garg, Amit K. ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :1849-1870
[5]   Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry [J].
Christensen, Gary E. ;
Song, Joo Hyun ;
Lu, Wei ;
El Naqa, Issarn ;
Low, Daniel A. .
MEDICAL PHYSICS, 2007, 34 (06) :2155-2163
[6]   Progressive damage on high resolution computed tomography despite stable lung function in cystic fibrosis [J].
de Jong, PA ;
Nakano, Y ;
Lequin, MH ;
Mayo, JR ;
Woods, R ;
Paré, PD ;
Tiddens, HAWM .
EUROPEAN RESPIRATORY JOURNAL, 2004, 23 (01) :93-97
[7]   4DCT-based measurement of changes in pulmonary function following a course of radiation therapy [J].
Ding, Kai ;
Bayouth, John E. ;
Buatti, John M. ;
Christensen, Gary E. ;
Reinhardt, Joseph M. .
MEDICAL PHYSICS, 2010, 37 (03) :1261-1272
[8]  
Gorbunova V., 2009, SPIE MED IMAGING
[9]  
Gorbunova V, 2008, LECT NOTES COMPUT SC, V5242, P863, DOI 10.1007/978-3-540-85990-1_104
[10]   Elastic image mapping for 4-D dose estimation in thoracic radiotherapy [J].
Guerrero, T ;
Zhang, G ;
Segars, W ;
Huang, TC ;
Bilton, S ;
Ibbott, G ;
Doug, L ;
Forster, K ;
Lin, KP .