Biomechanical Analysis of Supracondylar Humerus Fracture Pinning for Slightly Malreduced Fractures

被引:40
作者
Bloom, Tamir [1 ]
Robertson, Claire [1 ]
Mahar, Andrew T. [1 ,2 ]
Newton, Peter [1 ,2 ]
机构
[1] Rady Childrens Hosp San Diego, Dept Orthopaed, San Diego, CA USA
[2] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA 92103 USA
关键词
supracondylar humerus fracture; malreduction; pinning configuration; biomechanical stability;
D O I
10.1097/BPO.0b013e318186bdcd
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The most common position of malreduced type III supracondylar humerus (SCH) fractures is internal rotation and medial collapse of the distal fragment. The purpose of this study was to determine the effect of SCH fracture rotational deformity on stability with various pin configurations. Specifically, is the biomechanical stability lost when an SCH fracture is pinned in slight malreduction ( compared with anatomical pinning) improved by adding a third pin? Methods: Sixty-four synthetic humeri were sectioned in the midolecranon fossa to simulate an SCH fracture. Specimens were randomized to an anatomically reduced group or a group with 20 degrees of distal fragment internal rotation (n = 32 per group). Each was randomized to one of 4 pin configurations: 2 laterally divergent pins, 2 crossed pins, 3 laterally divergent pins, or 2 lateral with 1 medial pin ( n = 8 per group). All fractures were stabilized with 1.6 mm (0.062 in) Kirschner wires. Models were tested in extension, varus, and valgus for 10 cycles between 5 N and 50 N. Internal and external rotations were tested between +/- 1 Nm. Data for fragment stiffness ( newtons per millimeter or newton millimeters per degree) were analyzed with a 2-way analysis of variance (p < 0.05). Results: Internally rotated fractures were significantly less stable than the anatomically reduced group for external rotation, internal rotation, and varus loading regardless of pin configuration. Within the malreduced group, 3-pin configurations were more stable than 2-pin configurations in internal rotation, varus, and extension loading. Two lateral divergent pins were similar to 2 crossed pins, except in extension, where 2 lateral pins had greater stiffness. Conclusions: Construct stiffness for malreduced specimens after pinning was less than those pinned with an anatomical reduction when loaded in varus, internal rotation, and external rotation. For simulated fractures with residual internal rotation, the addition of a third Kirschner wire compared with an anatomically reduced 2-crossed-pin configuration resulted in increased stiffness of the model for all loading directions. Clinical Relevance: Consider a 3-pin pattern, either 3 laterally divergent pins or 2 lateral pins and 1 medial pin, for SCH fractures when a less than complete anatomical reduction is obtained.
引用
收藏
页码:766 / 772
页数:7
相关论文
共 49 条
  • [21] KASSER JR, 2005, ROCKWOOD WILKINS FRA, P563
  • [22] Lateral entry compared with medial and lateral entry pin fixation for completely displaced supracondylar humeral fractures in children - A Randomized clinical trial
    Kocher, Mininder S.
    Kasser, James R.
    Waters, Peter M.
    Bae, Donald
    Snyder, Brian D.
    Hresko, M. Timothy
    Hedequist, Daniel
    Karlin, Lawrence
    Kim, Young-Jo
    Murray, Martha M.
    Millis, Michael B.
    Emans, John B.
    Dichtel, Laura
    Matheney, Travis
    Lee, Ben M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) : 706 - 712
  • [23] KURER MHJ, 1990, CLIN ORTHOP RELAT R, P205
  • [24] Biomechanical analysis of pinning techniques for pediatric supracondylar humerus fractures
    Larson, Loren
    Firoozbakhsh, Keikhosrow
    Passarelli, Ralph
    Bosch, Patrick
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2006, 26 (05) : 573 - 578
  • [25] Displaced pediatric supracondylar humerus fractures: Biomechanical analysis of percutaneous pinning techniques
    Lee, SS
    Mahar, AT
    Miesen, D
    Newton, PO
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2002, 22 (04) : 440 - 443
  • [26] Treatment of multidirectionally unstable supracondylar humeral fractures in children - A modified Gartland type-IV fracture
    Leitch, KK
    Kay, RM
    Femino, JD
    Tolo, VT
    Storer, SK
    Skaggs, DL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (05) : 980 - 985
  • [27] Ulnar nerve palsies after percutaneous cross-pinning of supracondylar fractures in children's elbows
    Lyons, JP
    Ashley, E
    Hoffer, MM
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1998, 18 (01) : 43 - 45
  • [28] Biomechanical comparison of stainless steel and titanium nails for fixation of simulated femoral fractures
    Mahar, AT
    Lee, SS
    Lalonde, FD
    Impelluso, T
    Newton, PO
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2004, 24 (06) : 638 - 641
  • [29] Systematic pinning of displaced extension-type supracondylar fractures of the humerus in children
    Mazda, K
    Boggione, C
    Fitoussi, F
    Penneçot, GF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06): : 888 - 893
  • [30] Mehlman C T, 1996, Acta Orthop Belg, V62 Suppl 1, P41