Discriminating between Absorption and Scattering Effects in Complex Turbid Media by Coupling Polarized Light Spectroscopy with the Mueller Matrix Concept

被引:2
作者
Ducanchez, Arnaud [1 ]
Ryckewaert, Maxime [2 ]
Heran, Daphne [2 ]
Bendoula, Ryad [2 ]
机构
[1] Univ Montpellier, Inst Agro, ITAP, INRAE, F-34060 Montpellier, France
[2] Univ Montpellier, INRAE, ITAP, F-34196 Montpellier, France
关键词
spectroscopy; polarization; Mueller matrix; complex media; absorption; scattering; PLS; OPTICAL-PROPERTIES; DIFFUSE-REFLECTANCE; INFRARED-SPECTROSCOPY; CHEMICAL INFORMATION; LINEAR-POLARIZATION; PARTICLE-SIZE; MODEL; ABSORBENCY; STANDARD; PHANTOMS;
D O I
10.3390/s22239355
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation of the combined effects of absorption and scattering in complex media is a major issue for better characterization and prediction of media properties. In this study, an approach coupling polarized light spectroscopy and the Mueller matrix concept were evaluated to address this issue. A set of 50 turbid liquid optical phantoms with different levels of scattering and absorption properties were made and measured at various orientations of polarizers and analyzers to obtain the 16 elements of the complete Mueller matrix in the VIS-NIR region. Partial least square (PLS) was performed to build calibration models from diffuse reflectance spectra in order to evaluate the potential of polarization spectroscopy through the elements of the Mueller matrix to predict physical and chemical parameters and hence, to discriminate scattering and absorption effects, respectively. In particular, it was demonstrated that absorption and scattering effects can be distinguished in the Rayleigh regime with linear and circular polarization from the M-22 and M-44 elements of the Mueller matrix, correspondingly.
引用
收藏
页数:12
相关论文
共 45 条
  • [1] Time-resolved NIR spectroscopy for quantitative analysis of intact pharmaceutical tablets
    Abrahamsson, C
    Johansson, J
    Andersson-Engels, S
    Svanberg, S
    Folestad, S
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (04) : 1055 - 1059
  • [2] Supercontinuum laser based optical characterization of Intralipid® phantoms in the 500-2250 nm range
    Aernouts, Ben
    Zamora-Rojas, Eduardo
    Van Beers, Robbe
    Watte, Rodrigo
    Wang, Ling
    Tsuta, Mizuki
    Lammertyn, Jeroen
    Saeys, Wouter
    [J]. OPTICS EXPRESS, 2013, 21 (26): : 32450 - 32467
  • [3] Emerging optical spectroscopy techniques for biomedical applications-A brief review of recent progress
    Ahn, Heesang
    Song, Hyerin
    Shin, Dong-Myeong
    Kim, Kyujung
    Choi, Jong-ryul
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2018, 53 (2-4) : 264 - 278
  • [4] [Anonymous], NZ DATA SHEET
  • [5] [Anonymous], OMLC WEBSITE METHYLE
  • [6] Multi-block SO-PLS approach based on infrared spectroscopy for anaerobic digestion process monitoring
    Awhangbo, L.
    Bendoula, R.
    Roger, J. M.
    Beline, F.
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2020, 196 (196)
  • [7] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [8] Improvement of the Chemical Content Prediction of a Model Powder System by Reducing Multiple Scattering Using Polarized Light Spectroscopy
    Bendoula, Ryad
    Gobrecht, Alexia
    Moulin, Benoit
    Roger, Jean-Michel
    Bellon-Maurel, Veronique
    [J]. APPLIED SPECTROSCOPY, 2015, 69 (01) : 95 - 102
  • [9] Combining SO-PLS and linear discriminant analysis for multi-block classification
    Biancolillo, Alessandra
    Mage, Ingrid
    Naes, Tormod
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 141 : 58 - 67
  • [10] STOKES VECTORS, MUELLER MATRICES, AND POLARIZED SCATTERED-LIGHT
    BICKEL, WS
    BAILEY, WM
    [J]. AMERICAN JOURNAL OF PHYSICS, 1985, 53 (05) : 468 - 478