Detection of Listeria Monocytogenes by Electrochemical Impedance Spectroscopy

被引:34
作者
Radhakrishnan, Rajeswaran [1 ]
Jahne, Michael [2 ]
Rogers, Shane [2 ]
Suni, Ian I. [1 ,3 ]
机构
[1] Clarkson Univ, Mat Sci & Engn Program, Potsdam, NY 13699 USA
[2] Clarkson Univ, Dept Civil & Environm Engn, Potsdam, NY 13699 USA
[3] Clarkson Univ, Dept Chem & Biomol Engn, Potsdam, NY 13699 USA
基金
美国国家科学基金会;
关键词
Biosensors; Electrochemical Impedance Spectroscopy; Food Pathogens; Immunoassays; SELF-ASSEMBLED MONOLAYERS; REAL-TIME PCR; RAPID DETECTION; RISK-ASSESSMENT; SURFACES; BIOSENSOR; SENSORS; ARRAYS; GOLD;
D O I
10.1002/elan.201300140
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Listeria monocytogenes is detected by electrochemical impedance spectroscopy using a mouse monoclonal antibody immobilized onto an Au electrode. This yields sensitivities of 0.825k cm(2)/(CFU/mL) and 1.129k cm(2)/(CFU/mL) and detection limits of 5CFU/mL and 4CFU/mL for ideal solutions and filtered tomato extract, respectively. Control experiments with an Au electrode onto which a mouse monoclonal antibody to GAPDH is immobilized demonstrate that non-specific adsorption is insignificant for the system and methodology studied here. Control experiments with Salmonella enterica demonstrate no cross-reactivity to this food pathogen. Potential technological hurdles to development of a multiplexed impedance biosensor for food pathogens are also discussed.
引用
收藏
页码:2231 / 2237
页数:7
相关论文
共 46 条
  • [1] [Anonymous], 2011, Bacteriological Analytical Manual
  • [2] [Anonymous], ELECTROCHIM ACTA
  • [3] Decreasing listeriosis mortality in the United States, 1990-2005
    Bennion, Jonathan R.
    Sorvillo, Frank
    Wise, Matthew E.
    Krishna, Sheila
    Mascola, Laurene
    [J]. CLINICAL INFECTIOUS DISEASES, 2008, 47 (07) : 867 - 874
  • [4] A NONLINEAR LEAST-SQUARES FIT PROCEDURE FOR ANALYSIS OF IMMITTANCE DATA OF ELECTROCHEMICAL SYSTEMS
    BOUKAMP, BA
    [J]. SOLID STATE IONICS, 1986, 20 (01) : 31 - 44
  • [5] Integrated description of electrode/electrolyte interfaces based on equivalent circuits and its verification using impedance measurements
    Chang, BY
    Park, SM
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (04) : 1052 - 1060
  • [6] Covalent Functionalizations of Silicon Surfaces and Their Application to Biosensors
    Chazalviel, J. -N.
    Allongue, P.
    Gouget-Laemmel, A. C.
    de Villeneuve, C. Henry
    Moraillon, A.
    Ozanam, F.
    [J]. SCIENCE OF ADVANCED MATERIALS, 2011, 3 (03) : 332 - 353
  • [7] Health risk assessment of Listeria monocytogenes in Canada
    Farber, JM
    Ross, WH
    Harwig, J
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1996, 30 (1-2) : 145 - 156
  • [8] Electrochemical impedance study of self-assembled layer-by-layer iron-silicotungstate/poly(ethylenimine) modified electrodes
    Fernandes, Diana M.
    Ghica, Mariana E.
    Cavaleiro, Ana M. V.
    Brett, Christopher M. A.
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (23) : 7940 - 7945
  • [9] Detection of low levels of Listeria monocytogenes cells by using a fiber-optic immunosensor
    Geng, T
    Morgan, MT
    Bhunia, AK
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (10) : 6138 - 6146
  • [10] Invasive listeriosis in Denmark 1994-2003: a review of 299 cases with special emphasis on risk factors for mortality
    Gerner-Smidt, P
    Ethelberg, S
    Schiellerup, P
    Christensen, JJ
    Engberg, J
    Fussing, V
    Jensen, A
    Jensen, C
    Petersen, AM
    Bruun, BG
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2005, 11 (08) : 618 - 624