The repeatability of clinical measurements of dry eye

被引:397
作者
Nichols, KK [1 ]
Mitchell, GL [1 ]
Zadnik, K [1 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
关键词
dry eye; keratoconjunctivitis sicca; reproducibility; tears; diagnostic tests;
D O I
10.1097/00003226-200404000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The repeatability of individual dry eye diagnostic tests has been reported in the literature on normal samples of patients and to a lesser degree in dry eye patients. In this study, the repeatability of a battery of clinical diagnostic tests for dry eye was assessed on mild to moderate dry eye patients. Methods: A dry eye examination was performed on 75 patients on two occasions by a single examiner. The battery of dry eye tests included symptom assessment, contact lens and medical history, slit-lamp biomicroscopic evaluation of the eyelids, evaluation of Meibomian glands, assessment of tear film quality, tear meniscus height, assessment of blink quality, fluorescein tear breakup time (TBUT), fluorescein and rose bengal staining of the cornea and conjunctiva, phenol red thread test, and Schirmer test. Results: The repeatability of subjective report of dryness (kappa(w) = 0.62) and grittiness (kappa(w) = 0.73) was moderate to high. in contrast, the repeatability of Meibomian gland disease classification (kappa(w) = 0.20), presence or absence of inferior corneal fluorescein staining (kappa = 0.25), and inferior conjunctival rose bengal staining (kappa = 0.21) was poor. When a summed staining score of corneal and conjunctival regions was evaluated, weighted K reliability was fair. The repeatability of tear breakup time was substantial [95% limits of agreement -5.71 to 5.83 seconds; imtraclass coefficient coefficient (ICC) 0.65], and improved when die two timed readings were averaged. Repeatability of the Schirmer test is more variable as wetting scores increase. When the average Schirmer scores :5:10 turn were evaluated, moderate repeatability was demonstrated, indicating that the test performs better with more advanced disease. Conclusion: Although patient-reported symptoms are moderately repeatable from visit to visit, many of the procedures clinically used to diagnose and monitor dry eye syndromes are largely unrepeatable.
引用
收藏
页码:272 / 285
页数:14
相关论文
共 30 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
BandeenRoche R, 1997, INVEST OPHTH VIS SCI, V38, P2469
[3]   Corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study: Baseline prevalence and repeatability of detection [J].
Barr, JT ;
Schechtman, KB ;
Fink, BA ;
Pierce, GE ;
Pensyl, CD ;
Zadnik, K ;
Gordon, MO .
CORNEA, 1999, 18 (01) :34-46
[4]  
Bjerrum KB, 1996, ACTA OPHTHALMOL SCAN, V74, P436
[5]   A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
BRON A J, 1991, Eye (London), V5, P395
[8]   CORNEAL STAINING AFTER SEQUENTIAL INSTILLATIONS OF FLUORESCEIN OVER 30 DAYS [J].
CAFFERY, BE ;
JOSEPHSON, JE .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (06) :467-469
[9]   REVIEW OF THE TEAR BREAK-UP TIME AND A CLOSER LOOK AT THE TEAR BREAK-UP TIME OF HONG-KONG CHINESE [J].
CHO, P ;
BROWN, B .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (01) :30-38
[10]   THE COTTON THREAD TEST - A BRIEF REVIEW AND A CLINICAL-STUDY OF ITS RELIABILITY ON HONG-KONG CHINESE [J].
CHO, P .