Determination of semicarbazide in baby food by liquid chromatography/tandem mass spectrometry: Interlaboratory validation study

被引:0
|
作者
Ginn, Richard
Wilson, Lesley
De Souza, Scheilla V. C.
De la Calle, Maria B.
Barbosa, J.
Berendsen, B.
Bockborn, I.
Brandtner, M.
Delahaut, P.
Doering, T.
Fuerst, P.
Griffin, C.
Gude, T.
Janosi, A.
Jaus, A.
Kennedy, G.
Mandix, M.
Hilla, E. Matencio
Plonevez, S.
Posyniak, A.
Saari, L.
van Bruijnsvoort, M.
Verdon, E.
Wohlfarth, R.
机构
[1] Univ Fed Minas Gerais, Fac Farm, Dept Alimentos, BR-31270010 Belo Horizonte, MG, Brazil
[2] Cent Sci Lab, York YO41 1LZ, N Yorkshire, England
[3] European Commiss, DG Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An interlaboratory validation study funded by the European Commission, Directorate General for Health and Consumer Protection (DG SANCO), was conducted to evaluate the effectiveness of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of semicarbazide (SEM) in different types of baby food at a possible future European regulatory limit (10 ng/g). The test portion of the sample was extracted with hydrochloric acid, and the analyte was derivatized with 2-nitrobenzaidehyde, with 1,2-[N-15(2), C-13] SEM as an internal standard. The extract was neutralized and then purified on a solid-phase extraction cartridge. The SEM was determined by reversed-phase LC with detection by MS/MS. Apple puree, rice pudding, and meat/vegetable meal baby food materials, spiked with SEM at levels of about 3, 10, and 30 ng/g, respectively, were sent to 20 laboratories in 12 different European countries, which submitted results from 17 participants. Recoveries ranged from 88.8 to 106.1%. Based on results for spiked samples (blind pairs at 3 levels), the relative standard deviations for repeatability (RSD,) ranged from 4.2 to 6.9% and the relative standard deviations for reproducibility (RSDR) ranged from 16.6 to 24.3%. The method showed acceptable within- and between-laboratory precision for all 3 matrixes, as evidenced by HorRat values, at the target levels for the determination of SEM.
引用
收藏
页码:728 / 734
页数:7
相关论文
共 50 条
  • [21] Determination of commonly abused dyes in food by liquid chromatography-tandem mass spectrometry
    Yi Xionghai
    Deng Xiaojun
    Yang Huiqin
    Guo Dehua
    Zhu Jian
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (11) : 1062 - 1069
  • [22] Simultaneous Determination of Nine Sweeteners in Food by Liquid Chromatography-Tandem Mass Spectrometry
    Tong L.
    Dai Z.
    Xiao Z.
    Zhang L.
    Zou X.
    Yu W.
    Journal of Food Science and Technology (China), 2020, 38 (02): : 121 - 126
  • [23] Determination of cyclopiazonic acid in food and feeds by liquid chromatography-tandem mass spectrometry
    Moldes-Anaya, Angel S.
    Asp, Tone N.
    Eriksen, Gunnar S.
    Skaar, Ida
    Rundberget, Thomas
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3812 - 3818
  • [24] Determination of ethylenebisdithiocarbamate and propylenebisdithiocarbamate fungicides in food using liquid chromatography tandem mass spectrometry
    Sayed, Ramadan
    Hussein, Osama E.
    Omran, Ahmed A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (16) : 3787 - 3799
  • [25] Determination of phthalic acid esters in different baby food samples by gas chromatography tandem mass spectrometry
    Socas-Rodriguez, Barbara
    Gonzalez-Salamo, Javier
    Herrera-Herrera, Antonio, V
    Santana-Mayor, Alvaro
    Hernandez-Borges, Javier
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (22) : 5617 - 5628
  • [26] Determination of phthalic acid esters in different baby food samples by gas chromatography tandem mass spectrometry
    Bárbara Socas-Rodríguez
    Javier González-Sálamo
    Antonio V. Herrera-Herrera
    Álvaro Santana-Mayor
    Javier Hernández-Borges
    Analytical and Bioanalytical Chemistry, 2018, 410 : 5617 - 5628
  • [27] VALIDATION OF LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY METHODS - INTERLABORATORY STUDIES
    JONES, TL
    BETOWSKI, LD
    LOPEZAVILA, V
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (08) : 333 - 338
  • [28] Determination of zearalenone by liquid chromatography/tandem mass spectrometry and application to a pharmacokinetic study
    Shin, Beom Soo
    Hong, Seok Hyun
    Hwang, Sang Wook
    Kim, Hyoung Jun
    Lee, Jong Bong
    Yoon, Hae-Seong
    Kim, Do Jung
    Yoo, Sun Dong
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (09) : 1014 - 1021
  • [29] Determination of ephedra alkaloids by liquid chromatography/tandem mass spectrometry
    Sullivan, D. (darryl.sullivan@covance.com), 1600, AOAC International (86):
  • [30] Development and Validation of an Analytical Method for the Determination of Aloin Using Liquid Chromatography Tandem Mass Spectrometry
    Chris Anagnostopoulos
    George Ampadogiannis