Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves

被引:21
作者
Sarkar, Kunal [1 ]
Sardella, Gennaro [2 ]
Romeo, Francesco [3 ]
De Benedictis, Mauro [4 ]
Tarsia, Giandomenico [5 ]
Iadanza, Alessandro [6 ]
Sharma, Samin. K. [7 ]
Barbanti, Marco [1 ]
Tamburino, Corrado [1 ]
Ussia, Gian Paolo [1 ]
机构
[1] Univ Catania, Ferrarotto Hosp, Div Cardiol, Catania, Italy
[2] Univ Roma La Sapienza, Policlin Umberto I, Dept Cardiol, Rome, Italy
[3] Univ Roma Tor Vergata, Dept Cardiol, Policlin Tor Vergata, Rome, Italy
[4] Osped Mauriziano Umberto 1, Dept Cardiol, Turin, Italy
[5] Osped San Carlo Borromeo Milano, Dept Cardiol, Potenza, Italy
[6] Osped Le Scotte, Dept Cardiol, Siena, Italy
[7] Mt Sinai Hosp, Cardiac Catheterizat Lab, New York, NY 10029 USA
关键词
VALV; valvular heart disease; CATH; diagnostic cardiac catheterization; COMP; complications adult cath; intervention; VALVULAR HEART-DISEASE; TASK-FORCE; MANAGEMENT; COREVALVE; OUTCOMES; REPLACEMENT; GUIDELINES; STENOSIS; SOCIETY; RISK;
D O I
10.1002/ccd.24479
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We evaluated transcatheter aortic valve Implantation (TAVI) in high-risk patients with severe aortic regurgitation (AR) in native or degenerated bioprosthetic valves. Background: TAVI has emerged as a viable treatment modality for severe aortic stenosis in inoperable or high-risk patients. The use of TAVI for treatment of severe AR has remained largely unexplored. Methods Eight patients (age 79.6 years +/- 5.75 years) with severe AR underwent TAVI at six tertiary hospitals between April 2010 and May 2011. All patients were considered to be at prohibitive risk for surgical aortic valve replacement (SAVR).TAVI with the nitinol based Core Valve bioprosthesis (CRS) (Medtronic) was performed in all patients. Results Transfemoral access was used in all cases. Procedural success was obtained in all cases without any intraprocedural complications. There was no in hospital or 30-day mortality. There were no cases of atrioventricular blocks requiring permanent pacemaker implantation. At a mean follow up of 15.5 +/- 15 months; all patients had improvement in New York Heart Association functional class. Follow up echocardiography revealed improved or stable left ventricular ejection fraction and optimal device function in all cases. Conclusions TAVI with the CRS bioprosthesis is feasible and effective in appropriately selected cases of severe aortic regurgitation in native and bioprosthetic aortic valves.(c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:864 / 870
页数:7
相关论文
共 20 条
  • [1] Accola KD, 2008, J HEART VALVE DIS, V17, P355
  • [2] Transcatheter Valve-in-Valve Implantation Using Core Valve Revalving System for Failed Surgical Aortic Bioprostheses
    Bedogni, Francesco
    Laudisa, Maria Luisa
    Pizzocri, Samuele
    Tamburino, Corrado
    Ussia, Gian Paolo
    Petronio, Anna Sonia
    Napodano, Massimo
    Ramondo, Angelo
    Presbitero, Patrizia
    Ettori, Federica
    Santoro, Gennaro
    Klugman, Silvio
    De Marco, Federico
    Brambilla, Nedy
    Testa, Luca
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) : 1228 - 1234
  • [3] Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.05.007]
  • [4] Calvi V, 2011, J INTERV CARD ELECTR
  • [5] AORTIC-VALVE REPLACEMENT FOR AORTIC-STENOSIS IN PERSONS AGED 80 YEARS AND OVER
    CULLIFORD, AT
    GALLOWAY, AC
    COLVIN, SB
    GROSSI, EA
    BAUMANN, FG
    ESPOSITO, R
    RIBAKOVE, GH
    SPENCER, FC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (15) : 1256 - 1260
  • [6] Valve-in-Valve Transcatheter Aortic Valve Implantation for Degenerated Bioprosthetic Heart Valves
    Eggebrecht, Holger
    Schaefer, Ulrich
    Treede, Hendrik
    Boekstegers, Peter
    Babin-Ebell, Joerg
    Ferrari, Markus
    Moellmann, Helge
    Baumgartner, Helmut
    Carrel, Thierry
    Kahlert, Philipp
    Lange, Philipp
    Walther, Thomas
    Erbel, Raimund
    Mehta, Rajendra H.
    Thielmann, Matthias
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) : 1218 - 1227
  • [7] Transcatheter Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves
    Gurvitch, Ronen
    Cheung, Anson
    Ye, Jian
    Wood, David A.
    Willson, Alexander B.
    Toggweiler, Stefan
    Binder, Ronald
    Webb, John G.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) : 2196 - 2209
  • [8] Jaussaud N, 2009, J HEART VALVE DIS, V18, P256
  • [9] Transcatheter Aortic Valve Implantation for Stenosed and Regurgitant Aortic Valve Bioprostheses CoreValve for Failed Bioprosthetic Aortic Valve Replacements
    Khawaja, Muhammed Z.
    Haworth, Peter
    Ghuran, Azad
    Lee, Lorraine
    de Belder, Adam
    Hutchinson, Neville
    Trivedi, Uday
    Laborde, Jean-Claude
    Hildick-Smith, David
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (02) : 97 - 101
  • [10] Langley SM, 2000, J HEART VALVE DIS, V9, P697