Electron-event representation data enable efficient cryoEM file storage with full preservation of spatial and temporal resolution

被引:64
作者
Guo, Hui [1 ,2 ]
Franken, Erik [3 ]
Deng, Yuchen [3 ]
Benlekbir, Samir [1 ]
Lezcano, Garbi Singla [3 ]
Janssen, Bart [3 ]
Yu, Lingbo [3 ]
Ripstein, Zev A. [1 ,4 ]
Tan, Yong Zi [1 ]
Rubinstein, John L. [1 ,2 ,4 ]
机构
[1] Hosp Sick Children, Mol Med Program, 686 Bay St, Toronto, ON M5G 0A4, Canada
[2] Univ Toronto, Dept Med Biophys, 101 Coll St, Toronto, ON M5G 1L7, Canada
[3] Thermo Fisher Sci, Achtseweg Noord 5, NL-5651 GG Eindhoven, Netherlands
[4] Univ Toronto, Dept Biochem, 1 Kings Coll Circle, Toronto, ON M5S 1A8, Canada
来源
IUCRJ | 2020年 / 7卷
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
electron-event representation; cryoEM; direct detector device; BEAM-INDUCED MOTION; BAYESIAN-APPROACH; EM; CRYOMICROSCOPY; PARTICLES; MOVIES;
D O I
10.1107/S205225252000929X
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Direct detector device (DDD) cameras have revolutionized electron cryomicroscopy (cryoEM) with their high detective quantum efficiency (DQE) and output of movie data. A high ratio of camera frame rate (frames per second) to camera exposure rate (electrons per pixel per second) allows electron counting, which further improves the DQE and enables the recording of super-resolution information. Movie output also allows the correction of specimen movement and compensation for radiation damage. However, these movies come at the cost of producing large volumes of data. It is common practice to sum groups of successive camera frames to reduce the final frame rate, and therefore the file size, to one suitable for storage and image processing. This reduction in the temporal resolution of the camera requires decisions to be made during data acquisition that may result in the loss of information that could have been advantageous during image analysis. Here, experimental analysis of a new electron-event representation (EER) data format for electron-counting DDD movies is presented, which is enabled by new hardware developed by Thermo Fisher Scientific for their Falcon DDD cameras. This format enables the recording of DDD movies at the raw camera frame rate without sacrificing either spatial or temporal resolution. Experimental data demonstrate that the method retains super-resolution information and allows the correction of specimen movement at the physical frame rate of the camera while maintaining manageable file sizes. The EER format will enable the development of new methods that can utilize the full spatial and temporal resolution of DDD cameras.
引用
收藏
页码:860 / 869
页数:10
相关论文
共 28 条
[1]   Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles [J].
Bai, Xiao-chen ;
Fernandez, Israel S. ;
McMullan, Greg ;
Scheres, Sjors H. W. .
ELIFE, 2013, 2
[2]   The resolution dependence of optimal exposures in liquid nitrogen temperature electron cryomicroscopy of catalase crystals [J].
Baker, Lindsay A. ;
Smith, Eric A. ;
Bueler, Stephanie A. ;
Rubinstein, John L. .
JOURNAL OF STRUCTURAL BIOLOGY, 2010, 169 (03) :431-437
[3]   Beam-induced motion of vitrified specimen on holey carbon film [J].
Brilot, Axel F. ;
Chen, James Z. ;
Cheng, Anchi ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Henderson, Richard ;
Grigorieff, Nikolaus .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) :630-637
[4]   Movies of Ice-Embedded Particles Enhance Resolution in Electron Cryo-Microscopy [J].
Campbell, Melody G. ;
Cheng, Anchi ;
Brilot, Axel F. ;
Moeller, Arne ;
Lyumkis, Dmitry ;
Veesler, David ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Grigorieff, Nikolaus .
STRUCTURE, 2012, 20 (11) :1823-1828
[5]  
Chen JZ, 2018, IEEE INT C BIOINFORM, P2442, DOI 10.1109/BIBM.2018.8621120
[6]   MRC2014: Extensions to the MRC format header for electron cryo-microscopy and tomography [J].
Cheng, Anchi ;
Henderson, Richard ;
Mastronarde, David ;
Ludtke, Steven J. ;
Schoenmakers, Remco H. M. ;
Short, Judith ;
Marabini, Roberto ;
Dallakyan, Sargis ;
Agard, David ;
Winn, Martyn .
JOURNAL OF STRUCTURAL BIOLOGY, 2015, 192 (02) :146-150
[7]   Evaluation of super-resolution performance of the K2 electron-counting camera using 2D crystals of aquaporin-O [J].
Chiu, Po-Lin ;
Li, Xueming ;
Li, Zongli ;
Beckett, Brian ;
Brilot, Axel F. ;
Grigorieff, Nikolaus ;
Agard, David A. ;
Cheng, Yifan ;
Walz, Thomas .
JOURNAL OF STRUCTURAL BIOLOGY, 2015, 192 (02) :163-173
[8]   Reducing cryoEM file storage using lossy image formats [J].
Eng, Edward T. ;
Kopylov, Mykhailo ;
Negro, Carl J. ;
Dallaykan, Sarkis ;
Rice, William J. ;
Jordan, Kelsey D. ;
Kelley, Kotaro ;
Carragher, Bridget ;
Potter, Clinton S. .
JOURNAL OF STRUCTURAL BIOLOGY, 2019, 207 (01) :49-55
[9]  
Feathers J. R., 2019, BIORXIV
[10]   A Fast and Effective Microfluidic Spraying-Plunging Method for High-Resolution Single-Particle Cryo-EM [J].
Feng, Xiangsong ;
Fu, Ziao ;
Kaledhonkar, Sandip ;
Jia, Yuan ;
Shah, Binita ;
Jin, Amy ;
Liu, Zheng ;
Sun, Ming ;
Chen, Bo ;
Grassucci, Robert A. ;
Ren, Yukun ;
Jiang, Hongyuan ;
Frank, Joachim ;
Lin, Qiao .
STRUCTURE, 2017, 25 (04) :663-+