Amperometric biosensor based on Prussian Blue nanoparticle-modified screen-printed electrode for estimation of glucose-6-phosphate

被引:22
作者
Banerjee, Suchanda [1 ]
Sarkar, Priyabrata [1 ]
Turner, Anthony P. F. [2 ]
机构
[1] Univ Calcutta, Dept Polymer Sci & Technol, Kolkata 700009, W Bengal, India
[2] IFM Linkoping Univ, Biosensors & Bioelect Ctr, S-58183 Linkoping, Sweden
关键词
Glucose-6-phosphate; Prussian Blue nanoparticles; Screen-printed electrode; Amperometry; HYDROGEN-PEROXIDE; GLUCOSE-OXIDASE; L-CYSTEINE; SENSOR; TRANSDUCER; LAYER; MONODISPERSE; METABOLISM; PHOSPHATE; POLYMER;
D O I
10.1016/j.ab.2013.04.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glucose-6-phosphate (G6P) plays an important role in carbohydrate metabolism of all living organisms. Compared with the conventional analytical methods available for estimation of G6P, the biosensors having relative simplicity, specificity, low cost, and fast response time are a promising alternative. We have reported a G6P biosensor based on screen-printed electrode using Prussian Blue (PB) nanoparticles and enzymes, glucose-6-phosphate dehydrogenase, and glutathione reductase. The PB nanoparticles acted as a mediator and thereby enhanced the rate of electron transfer in a bienzymatic reaction. The Fourier transform infrared spectroscopy and energy-dispersive X-ray spectroscopy study confirmed the formation of PB, whereas atomic force microscopy revealed that PB nanoparticles were approximately 25 to 30 nm in diameter. Various optimization studies, such as pH, enzyme, and cofactor loading, were conducted to obtain maximum amperometric responses for G6P measurement. The developed G6P biosensor showed a broad linear response in the range of 0.01 to 1.25 mM, with a detection limit of 2.3 mu M and sensitivity of 63.3 mu A/mM at a signal-to-noise ratio of 3 within 15 s at an applied working potential of -100 mV. The proposed G6P biosensor also exhibited good stability and excellent anti-interference ability, and it worked well for serum samples. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:194 / 200
页数:7
相关论文
共 38 条
[1]   Thermophilic glucokinase-based sensors for the detection of various saccharides and glycosides [J].
Aoki, K ;
Suzuki, H ;
Ishimaru, Y ;
Toyama, S ;
Ikariyama, Y ;
Iida, T .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :727-732
[2]   Amperometric Detection of Hexavalent Chromium with L-DOPA Modified Screen Printed Electrode [J].
Banerjee, Suchanda ;
Sarkar, Priyabrata .
SENSOR LETTERS, 2011, 9 (04) :1370-1375
[3]   Demonstration of a metabolically active glucose-B-phosphate pool in the lumen of liver microsomal vesicles [J].
Banhegyi, G ;
Marcolongo, P ;
Fulceri, R ;
Hinds, C ;
Burchell, A ;
Benedetti, A .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (21) :13584-13590
[4]   Mediated, amperometric biosensor for glucose-6-phosphate monitoring based on entrapped glucose-6-phosphate dehydrogenase, Mg2+ ions, tetracyanoquinodimethane, and nicotinamide adenine dinucleotide phosphate in carbon paste [J].
Bassi, AS ;
Tang, DQ ;
Bergougnou, MA .
ANALYTICAL BIOCHEMISTRY, 1999, 268 (02) :223-228
[5]   Ethanol formation and enzyme activities around glucose-6-phosphate in Kluyveromyces marxianus CBS 6556 exposed to glucose or lactose excess [J].
Bellaver, LH ;
de Carvalho, NMB ;
Abrahao-Neto, J ;
Gombert, AK .
FEMS YEAST RESEARCH, 2004, 4 (07) :691-698
[6]   Development of a voltammetric sensor for chromium(VI) determination in wastewater sample [J].
Bergamini, Marcio F. ;
dos Santos, Daniela P. ;
Boldrin Zanoni, Maria Valnice .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02) :902-908
[7]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[8]  
[陈桂芳 Chen Guifang], 2010, [生物物理学报, Acta Biophysica Sinica], V26, P711
[9]   Immobilization of Prussian blue nanoparticles onto thiol SAM modified Au electrodes for analysis of DL-homocysteine [J].
Chen, J. ;
Miao, Y. ;
Wu, X. .
COLLOID JOURNAL, 2007, 69 (05) :660-665
[10]   Multimode optoelectrochemical detection of cysteine based on an electrochromic Prussian blue electrode [J].
Chen, Lin-Chi ;
Ho, Kuo-Chuan .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :418-424