Renovation usually increases the aesthetic and market value of buildings. Consequently, with the rapid growth of the city's population and skyrocketing demand for decent housing, the current trend of building conversion and renovation of existing and dilapidated property stock within city centres has become rampant. The rise in demand has pushed beyond the boundaries that every real estate investor wants to maximize profit, and it has resulted in the prevalence of uncontrolled building development, land use conversion, and non-compliance with building requirements, etc. Renovations that involve changes in building elements (especially the window system) that can influence energy saving and ventilation efficiency have thus become very common. However, the effects of building renovations on ventilation and energy efficiency have not been fully examined, particularly in Enugu (Nigeria), a rapidly growing colonial metropolis. This research employed a qualitative research approach to investigate the effects of building renovation on ventilation and energy saving in Achara layout, Enugu City, Nigeria. Four blocks of flat residential buildings were the derived sample size using a judgmental sampling technique. Physical measurements, an observation schedule, and oral interviews with site workers centred on window size, area, property, and fenestration type were used to collect empirical data involving the window system. The result reveals a very significant difference between the as-built and renovated window design systems of all studied variables. Its conclusion hinged on the fact that a renovated structure does not encourage effective natural ventilation and hence will consume more energy in cooling and lighting. It recommends the re-introduction of appropriate window systems and construction techniques for the tropical environment to reduce heat stress build-up within building units.
引用
收藏
页码:124 / 134
页数:11
相关论文
共 45 条
[1]   Residential Satisfaction: Literature Review and A Conceptual Framework [J].
Abidin, Nurzafira Zainul ;
Abdullah, Mohamad Isa ;
Basrah, Noraliza ;
Alias, Muhammad Nazim .
4TH INTERNATIONAL CONFERENCE ON RESEARCH METHODOLOGY FOR BUILT ENVIRONMENT AND ENGINEERING 2019, 2019, 385
[2]  
Abiodun P. B., 2005, J APPL SCI, V5, P437, DOI [10.3923/jas.2005.437.440, DOI 10.3923/JAS.2005.437.440]
[3]  
Ajay G., 2021, Effective Fenestration through improved designs & Systems
[4]  
Alozie G. C., 2019, Development, V9, P1
[5]  
[Anonymous], 2019, 621 ANSIASHRAE
[6]   Ten questions concerning occupant health in buildings during normal operations and extreme events including the COVID-19 pandemic [J].
Awada, Mohamad ;
Becerik-Gerber, Burcin ;
Hoque, Simi ;
O'Neill, Zheng ;
Pedrielli, Giulia ;
Wen, Jin ;
Wu, Teresa .
BUILDING AND ENVIRONMENT, 2021, 188
[7]  
Ayoosu M. I., 2021, Journal of Daylighting, V8, P20, DOI [10.15627/jd.2021.2, DOI 10.15627/JD.2021.2]
[8]   Housing quality and its predictors in public residential estates in Lagos, Nigeria [J].
Babalola, Olatunde D. ;
Ibem, Eziyi O. ;
Olotuah, Abiodun O. ;
Opoko, Akunnaya P. ;
Adewale, Bukola A. ;
Fulani, Omoyeni A. .
ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2020, 22 (05) :3973-4005
[9]   Indoor thermal environmental conditions near glazed facades with shading devices - Part I: Experiments and building thermal model [J].
Bessoudo, M. ;
Tzempelikos, A. ;
Athienitis, A. K. ;
Zmeureanu, R. .
BUILDING AND ENVIRONMENT, 2010, 45 (11) :2506-2516
[10]  
Bhole V., 2021, MIDDLE E MAGAZINE