CREATION OF A 3D PRINTED PLEURAL DRAINAGE PLACEMENT MODEL

被引:0
作者
Sanz Duenas, J. [1 ]
de la Morena Garcia, E. [1 ]
de Gaspar Simon, I. [2 ]
Rojo Salvador, C. [2 ]
Rodriguez Quiros, J. [1 ]
Bernardi Villavicencio, C. [1 ,3 ]
Perez Diaz, C. [1 ]
机构
[1] Univ Complutense Madrid, Dept Anim Med & Surg, Fac Vet Med, Madrid, Spain
[2] Univ Complutense Madrid, Dept Anat & Embryol, Fac Vet Med, Madrid, Spain
[3] Univ Cuenca, Cuenca, Ecuador
来源
11TH INTERNATIONAL CONFERENCE OF EDUCATION, RESEARCH AND INNOVATION (ICERI2018) | 2018年
关键词
3D printing; veterinary; pleural drainage; teaching; innovation; technology; SURGICAL-CORRECTION; MEDICAL INTERNS; PLATE;
D O I
暂无
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
3D printing technologies are in a period of great development and so are their educational applications for health sciences. FDM (Fused Deposition Modeling) printers allow great advances in veterinary education by creating anatomical models adapted to learning needs. The knowledge of routine procedures in the veterinary clinic, such as the placement of a pleural drain, represents a key point in the practical training of students. The difficulties associated to obtaining, preparing and conserving cadavers makes their use in practical teaching very difficult. The models printed using FDM technology are a versatile, realistic and inexpensive tool that can be applied in teaching. In this study, a dog chest was created by segmentation of tomographic studies obtained from a live patient. This data allowed for the creation of a 3D mesh, which was used to create both virtual online access models and physical models manufactured with FDM printing technologies. This thorax introduced into a stuffed animal was used by students to understand and perform the placement and posterior fixation of a pleural drainage. In order to validate the developed pleural drainage placement model, 25 veterinary students with prior clinical experience (15 of them had observed the procedure in practice before) from the Complutense University of Madrid performed the placement procedure using the model. 71% of these students considered that the model was useful for understanding the location of anatomical structures and their relations to surrounding organs and tissues. 53% considered that pleural drainage placement in the model was anatomically equivalent to the animal. Participating students expressed their interest in the creation of other models of clinical practice FDM technology is capable of producing accurate, low-cost anatomical models, although its main limitation is printing speed. Virtualization and 3D printing are a new and effective educational tool with great potential for development. Both techniques are subject to a learning curve, which can be assumed thanks to the resources available online.X
引用
收藏
页码:1655 / 1661
页数:7
相关论文
共 24 条
[1]  
[Anonymous], ANK PSEUD TEMP JOINT
[2]   Regenerative approach to bilateral rostral mandibular reconstruction in a case series of dogs [J].
Arzi, Boaz ;
Cissell, Derek D. ;
Pollard, Rachel E. ;
Verstraete, Frank J. M. .
FRONTIERS IN VETERINARY SCIENCE, 2015, 2
[3]   Innovations in surgery simulation: a review of past, current and future techniques [J].
Badash, Ido ;
Burtt, Karen ;
Solorzano, Carlos A. ;
Carey, Joseph N. .
ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (23)
[4]   Current Applications and Future Perspectives of the Use of 3D Printing in Anatomical Training and Neurosurgery [J].
Baskaran, Vivek ;
Strkalj, Goran ;
Strkalj, Mirjana ;
Di Ieva, Antonio .
FRONTIERS IN NEUROANATOMY, 2016, 10
[5]   3-D printing: The new industrial revolution [J].
Berman, Barry .
BUSINESS HORIZONS, 2012, 55 (02) :155-162
[6]   Chest drainage teaching and training for medical students. Use of a surgical ex vivo pig model [J].
Carvalho Tube, Milton Ignacio ;
Campelo Spencer Netto, Fernando Antonio ;
Costa, Elaine ;
Araujo Lafayette, Daniell de Siqueira ;
Carvalho Antunes Lima, George Augusto da Fonseca ;
Santos de Menezes, Jamile Isabela ;
Buenos Aires, Vinicius Gueiros ;
Bandeira Ferraz, Alvaro Antonio ;
Campos, Josemberg Marins ;
de Moraes Neto, Fernando Ribeiro .
ACTA CIRURGICA BRASILEIRA, 2016, 31 (05) :353-363
[7]   Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial [J].
D'Urso, PS ;
Barker, TM ;
Earwaker, WJ ;
Bruce, LJ ;
Atkinson, RL ;
Lanigan, MW ;
Arvier, JF ;
Effeney, DJ .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (01) :30-37
[8]   Complex angular and torsional deformities (distal femoral malunions) Preoperative planning using stereolithography and surgical correction with locking plate fixation in four dogs [J].
DeTora, Michael D. ;
Boudrieau, Randy J. .
VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (05) :416-425
[9]   Use of radiographic measures and three-dimensional computed tomographic imaging in surgical correction of an antebrachial deformity in a dog [J].
Dismukes, David I. ;
Fox, Derek B. ;
Tomlinson, James L. ;
Essman, Stephanie C. .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2008, 232 (01) :68-73
[10]   Three-dimensional printing of orbital and peri-orbital masses in three dogs and its potential applications in veterinary ophthalmology [J].
Dorbandt, Daniel M. ;
Joslyn, Stephen K. ;
Hamor, Ralph E. .