Restarting strategy of UPFC series connect unit for fault ride-through based on fault identification

被引:0
|
作者
Lin Jinjiao [1 ]
Jiang Miao [2 ]
Huang Ruhai [2 ]
Xiangping, Kong [1 ]
机构
[1] State Grid Jiangsu Elect Power Co Res Inst, Nanjing 211103, Jiangsu, Peoples R China
[2] NR Elect Co Ltd, Nanjing 211102, Jiangsu, Peoples R China
来源
2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED) | 2018年
关键词
Unified power flow controller (UPFC); Control system; Fault Ride-through; Restarting strategy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the latest generation of Flexible AC Transmission System(FACTS) devices, UPFC integrates various flexible control means of FACTS components. Because of the weak insulation capacity of electronic equipment, UPFC fault ride-through capability is limited. This paper introduces the fast fault isolation technique of UPFC, and then a restarting strategy of UPFC series connect unit based on fault identification is put forward for improving fault ride-through capability. Based on comprehensively analyzing UPFC control protection system operation, AC protection operation, power gird status and switch position, the most appropriate operation mode of UPFC such as shutdown, switching mode or restarting to the original mode is determined. For the faults which are determined to restarting, the strategy detects different characteristic quantities for identifying fault recovery for different fault types, the restart of series connect unit is performed when conditions are satisfied. Then discrimination principle and implementation method of the strategy are represented in detail. And based on power flow transfer distribution factor method, the power instruction is adjusted quickly after UPFC restarting caused by remote power gird fault. The strategy is verified in simulation test for Nanjing 220kV power grid UPFC project. The result shows that it has good application feasibility and power grid adaptability, and the strategy can further improve UPFC fault ride through capability.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 50 条
  • [41] Fault Ride-through Control Strategy of MMC-HVDC System Under Asymmetric Grid Conditions
    Yu J.
    Liu C.
    Wang J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (17): : 5653 - 5664
  • [42] Staged coordinated fault ride-through strategy for hybrid cascaded multi-terminal DC system
    Yu J.
    Fan D.
    Xu K.
    Kong X.
    Zheng J.
    Dai Q.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (06): : 69 - 75
  • [43] An Improved Fault Ride-through of Grid Integrated Solar PV system
    Srujan, D.
    Ghanasyam, P.
    Mitra, Arghya
    PROCEEDINGS OF 2019 IEEE REGION 10 SYMPOSIUM (TENSYMP), 2019, : 355 - 360
  • [44] Fault ride-through of large wind farms using series dynamic braking resistors (March 2007)
    Causebrook, Andrew
    Atkinson, David J.
    Jack, Alan G.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) : 966 - 975
  • [45] Grid-Forming Nature Retaining Fault Ride-Through Control
    Awal, M. A.
    Rachi, Md Rifat Kaisar
    Yu, Hui
    Schroeder, Stefan
    Dannehl, Jorg
    Husain, Iqbal
    2023 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2023, : 2753 - 2758
  • [46] Wind Turbine Controller Design for improved Fault Ride-Through Ability
    Zhang, Fan
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2016), 2016, 98 : 45 - 55
  • [47] DC Short Circuit Fault Analysis of a Triple Active Bridge Converter for Fault Ride-Through Capability
    Dhiman, Shubham
    Sharma, Shrivatsal
    Aljumah, Osamah
    Bhattacharya, Subhashish
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 2112 - 2118
  • [48] Fault Ride-Through Behaviors Correction-Based Single-Unit Equivalent Method for Large Photovoltaic Power Plants
    Chao, Pupu
    Li, Weixing
    Peng, Simin
    Liang, Xiaodong
    Zhang, Lei
    Shuai, Yong
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2021, 12 (01) : 715 - 726
  • [49] Fault Ride-Through Capability of Doubly-Fed Induction Generators Based Wind Turbines
    Abobkr, Abobkr Hamida
    El-Hawary, M. E.
    2015 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2015, : 8 - 15
  • [50] Experimental study on fault ride-through capability of VSC-based HVDC transmission system
    Ngo Minh Khoa
    Nguyen An Toan
    Doan Duc Tung
    ARCHIVES OF ELECTRICAL ENGINEERING, 2021, 70 (01) : 37 - 51