Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

被引:29
|
作者
Schwartz, Andrew J. [1 ]
Ray, Steven J. [1 ,2 ]
Chan, George C. -Y. [1 ,3 ]
Hieftje, Gary M. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
[3] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
基金
美国能源部;
关键词
Solution-cathode glow discharge; Optical-emission spectrometry; Instrumentation; Spatial discrimination; FLAGGING MATRIX INTERFERENCES; ATMOSPHERIC-PRESSURE; ELEMENTAL ANALYSIS; ONLINE SEPARATION; AQUEOUS SAMPLES; SYSTEM DRIFT; PRECONCENTRATION; PROFILES; COMPACT; SILICA;
D O I
10.1016/j.sab.2016.10.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal to -background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09-360 ppb, a 1.4-13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1-840 ppb), with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from 0.5-2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4-2.4% RSD observed when no spatial filtering is used. Spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 176
页数:9
相关论文
共 50 条
  • [41] Solution Cathode Glow Discharge Atomic Emission Spectrometry in Hydrogen-Helium Atmosphere for On-line Determination of Chromium in Sewage
    Chen, Xiang-YU
    Cai, Zhao-Qing
    Pan, Yu-Bai
    Wang, Zheng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (08) : 1252 - 1259
  • [42] Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity
    Zhang, Zhen
    Wang, Zheng
    Li, Qing
    Zou, Huijun
    Shi, Ying
    TALANTA, 2014, 119 : 613 - 619
  • [43] Multi-element Simultaneous sensitization of solution cathode glow discharge atomic emission spectrometry by using portable semiconductor anode refrigeration
    Chen, Xiangyu
    Cai, Zhaoqing
    Wang, Zheng
    TALANTA, 2022, 248
  • [44] A novel capillary microplasma analytical system: interface-free coupling of glow discharge optical emission spectrometry to capillary electrophoresis
    Jiang, Xue
    Xu, Xinliang
    Hou, Xiandeng
    Long, Zhou
    Tian, Yunfei
    Jiang, Xiaoming
    Xu, Fujian
    Zheng, Chengbin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (07) : 1423 - 1429
  • [45] Mercury speciation by HPLC–cold-vapour radiofrequency glow-discharge optical-emission spectrometry with on-line microwave oxidation
    Roberto Martínez
    Rosario Pereiro
    Alfredo Sanz-Medel
    Nerea Bordel
    Fresenius’ Journal of Analytical Chemistry, 2001, 371 : 746 - 752
  • [46] Evaluation of the temporal profiles and the analytical features of a laser ablation - Pulsed glow discharge coupling for optical emission spectrometry
    Gonzalez de Vega, Claudia
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 121 : 47 - 54
  • [47] PRELIMINARY-STUDY OF THE ROLE OF DISCHARGE CONDITIONS ON THE IN-DEPTH ANALYSIS OF CONDUCTING THIN-FILMS BY RADIOFREQUENCY GLOW-DISCHARGE OPTICAL-EMISSION SPECTROMETRY
    BORDELGARCIA, N
    PEREIROGARCIA, R
    FERNANDEZGARCIA, M
    SANZMEDEL, A
    HARVILLE, TR
    MARCUS, RK
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) : 671 - 676
  • [48] Comparison of conventional linear regression method and interpretable artificial neural network for copper determination using optical emission spectroscopy of solution cathode glow discharge
    Khanh, Hoang Bao
    Duy, Nguyen Lam
    Tien, Nguyen Anh
    Khang, Nguyen Huynh Duy
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 219
  • [49] Atomization of arsenic hydride in a planar dielectric barrier discharge: Behavior of As atoms studied by temporally and spatially resolved optical emission spectrometry
    Burhenn, Sebastian
    Kratzer, Jan
    Klute, Felix David
    Dedina, Jiri
    Franzke, Joachim
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 152 : 68 - 73
  • [50] Analytical potential of a laser ablation-glow discharge-optical emission spectrometry system for the analysis of conducting and insulating materials
    Gonzalez de Vega, Claudia
    Alvarez Llamas, Cesar
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICA CHIMICA ACTA, 2015, 877 : 33 - 40