Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

被引:29
|
作者
Schwartz, Andrew J. [1 ]
Ray, Steven J. [1 ,2 ]
Chan, George C. -Y. [1 ,3 ]
Hieftje, Gary M. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
[3] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
基金
美国能源部;
关键词
Solution-cathode glow discharge; Optical-emission spectrometry; Instrumentation; Spatial discrimination; FLAGGING MATRIX INTERFERENCES; ATMOSPHERIC-PRESSURE; ELEMENTAL ANALYSIS; ONLINE SEPARATION; AQUEOUS SAMPLES; SYSTEM DRIFT; PRECONCENTRATION; PROFILES; COMPACT; SILICA;
D O I
10.1016/j.sab.2016.10.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal to -background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09-360 ppb, a 1.4-13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1-840 ppb), with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from 0.5-2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4-2.4% RSD observed when no spatial filtering is used. Spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 176
页数:9
相关论文
共 50 条
  • [31] Design modification of a solution-cathode glow discharge-atomic emission spectrometer for the determination of trace metals in titanium dioxide
    Wang, Zheng
    Gai, Rongyin
    Zhou, Lei
    Zhang, Zhen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (11) : 2042 - 2049
  • [32] Sensitivity improvement of solution cathode glow discharge-optical emission spectrometry by external magnetic field for optical determination of elements
    Zhou, Yong-Jie
    Ma, Jun
    Li, Fei
    Xian, Tao
    Yuan, Qiang-Hua
    Lu, Quan-Fang
    MICROCHEMICAL JOURNAL, 2020, 158
  • [33] Battery-operated portable high-throughput solution cathode glow discharge optical emission spectrometry for environmental metal detection
    Peng, Xiaoxu
    Guo, Xiaohong
    Ge, Fen
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (02) : 394 - 400
  • [34] GAS-SAMPLING GLOW-DISCHARGE FOR OPTICAL-EMISSION SPECTROMETRY .1. DESIGN AND OPERATING CHARACTERISTICS
    STARN, TK
    PEREIRO, R
    HIEFTJE, GM
    APPLIED SPECTROSCOPY, 1993, 47 (10) : 1555 - 1561
  • [35] Detection of some industrially relevant elements in water by electrolyte cathode atmospheric glow discharge optical emission spectrometry
    Bencs, Laszlo
    Laczai, Nikoletta
    Mezei, Pal
    Cserfalvi, Tamas
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 107 : 139 - 145
  • [36] COMPARISON OF DEPTH RESOLUTION FOR DIRECT-CURRENT AND RADIOFREQUENCY MODES IN GLOW-DISCHARGE OPTICAL-EMISSION SPECTROMETRY
    PRASSLER, F
    HOFFMANN, V
    SCHUMANN, J
    WETZIG, K
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) : 677 - 680
  • [37] Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk
    Hao Jun
    Wang Yu
    Liu Cong
    Wu Zan
    Shao Peng
    Zu Wen-chuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3797 - 3801
  • [38] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422
  • [39] Solution anode glow discharge optical emission spectrometry: Volatile hydride introduction from the gas jet nozzle cathode for ultrasensitive determination of
    Peng, Xiaoxu
    Zhao, Mingyue
    Yuan, Mingli
    Wang, Zheng
    TALANTA, 2021, 225
  • [40] Determination of calcium and zinc in gluconates oral solution and blood samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Wang, Xing
    Sun, Duixiong
    Wang, Yongqiang
    Yang, Wu
    TALANTA, 2017, 175 : 150 - 157