Application of spinal navigation with the intra-operative three-dimensional (3D)-imaging modality in difficult pedicle screw fixation

被引:0
|
作者
Wang, Feng-Xian [1 ]
Yu, Xing [1 ]
Bi, Lian-Yong [1 ]
Yang, Ji-Zhou [1 ]
Jiao, Yong [1 ]
Xu, Lin [1 ]
机构
[1] Beijing Univ Chinese Med, Dongzhimen Hosp, Dept Orthopaed, Beijing 100700, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2016年 / 9卷 / 07期
关键词
Spinal navigation; 3D-imaging; pedicle screw; spinal deformity; revision; ADOLESCENT IDIOPATHIC SCOLIOSIS; COMPUTED-TOMOGRAPHY; CONSECUTIVE PATIENTS; RADIATION-EXPOSURE; LEARNING-CURVE; PLACEMENT; ACCURACY; FLUOROSCOPY; LUMBAR; INSERTION;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of this study was to evaluate the efficacy and safety of an application using spinal navigation with the intra-operative three-dimensional (3D)-imaging modality in difficult pedicle screw fixation. 78 patients with congenital deformity of spinal column and spinal cord (41 cases) or spinal instability after laminectomy or semi-laminectomy (37 cases) were instrumented with pedicle screw system by spinal navigation with the intra-operative 3D-imaging system from September 2004 to September 2014 in our orthopedic department. The position of pedicle screw was assessed by intra-operative 3D-imaging system. The excellent rate of pedicle screw position, mean time of pedicle screw implanted, operating time, blood loss, post-operative complication were recorded. The excellent rate of pedicle screw position was 96% in these cases. The mean time of pedicle screw implanted, operating time and blood loss were 3.90 +/- 0.87 minutes, 147 +/- 65 minutes and 312 +/- 185 ml, respectively. There was no implant-related complication that occurred during operation. With spinal navigation combined with the intra-operative 3D-imaging modality, implantation of difficult pedicle screw in patients with congenital spinal deformity or spinal instability after laminectomy or semi-laminectomy is more simplified, more accurate, safer, and shorter time-consuming.
引用
收藏
页码:14191 / 14197
页数:7
相关论文
共 38 条
  • [21] A 3D navigation template for guiding a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation: a study protocol for multicentre randomised controlled trials
    Shao, Zhen-Xuan
    He, Wei
    He, Shao-Qi
    Lin, Sheng-Lei
    Huang, Zhe-Yu
    Tang, Hong-Chao
    Ni, Wen-Fei
    Wang, Xiang-Yang
    Wu, Ai-Min
    BMJ OPEN, 2017, 7 (07):
  • [22] A real-time 3D electromagnetic navigation system for percutaneous pedicle screw fixation in traumatic thoraco-lumbar fractures: implications for efficiency, fluoroscopic time, and accuracy compared with those of conventional fluoroscopic guidance
    Yao, Yawei
    Jiang, Xiang
    Wei, Tanjun
    Yao, Zhipeng
    Wu, Boyu
    Xu, Feng
    Xiong, Chengjie
    EUROPEAN SPINE JOURNAL, 2022, 31 (01) : 46 - 55
  • [23] Three-dimensional imaging in the context of minimally invasive and transcatheter cardiovascular interventions using multi-detector computed tomography: from pre-operative planning to intra-operative guidance
    Schoenhagen, Paul
    Numburi, Uma
    Halliburton, Sandra S.
    Aulbach, Peter
    von Roden, Martin
    Desai, Milind Y.
    Rodriguez, Leonardo L.
    Kapadia, Samir R.
    Tuzcu, E. Murat
    Lytle, Bruce W.
    EUROPEAN HEART JOURNAL, 2010, 31 (22) : 2727 - 2740A
  • [24] A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation
    Tian, Ye
    Zhang, Jianan
    Liu, Tuanjiang
    Tang, Shi
    Chen, Hao
    Ding, Keyuan
    Hao, Dingjun
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9981 - 9990
  • [25] Design and application of a novel patient-specific 3D printed drill navigational guiding template in percutaneous thoracolumbar pedicle screw fixation: A cadaveric study
    Li, Zhonghai
    Xu, Dingjun
    Li, FengNing
    Liu, Mozhen
    Xu, Gang
    Yang, Ming
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 73 : 294 - 298
  • [26] Percutaneous Pedicle Screw Fixation of a Hangman's Fracture Using Intraoperative, Full Rotation, Three-dimensional Image (O-arm)-based Navigation: A Technical Case Report
    Yoshida, Go
    Kanemura, Tokumi
    Ishikawa, Yoshimoto
    ASIAN SPINE JOURNAL, 2012, 6 (03) : 194 - 198
  • [27] Clinical application of 3D printing in pedicle screw fixation and fusion for the treatment of old type II odontoid fractures with posterior atlantoaxial dislocation
    Xiong, Moliang
    Chen, Ruisong
    Jian, Guojian
    Xia, Tao
    Liao, Xin
    Ye, Zhiyang
    Xu, Tianrui
    Huang, Jianming
    Huang, Yanpeng
    Feng, Zhijun
    Li, Yanfang
    Zheng, Honghua
    Wang, Zimin
    Liu, Haoyuan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (07): : 11244 - 11253
  • [28] Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sections
    Horst Balling
    Thomas R. Blattert
    European Spine Journal, 2017, 26 : 2898 - 2905
  • [29] A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion
    Takahata, Masahiko
    Yamada, Katsuhisa
    Akira, Iwata
    Endo, Tsutomu
    Sudo, Hideki
    Yokoyama, Hidetoki
    Iwasaki, Norimasa
    EUROPEAN SPINE JOURNAL, 2018, 27 (11) : 2754 - 2762
  • [30] Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D/3D imaging system
    Somoskeoey, Szabolcs
    Tunyogi-Csapo, Miklos
    Bogyo, Csaba
    Illes, Tamas
    SPINE JOURNAL, 2012, 12 (11) : 1052 - 1059