A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse

被引:12
作者
Walczak, Rafal [1 ]
Krueger, Jan [2 ]
Moynihan, Shane [2 ]
机构
[1] Wroclaw Univ Technol, Fac Microsyst Elect & Photon, PL-50372 Wroclaw, Poland
[2] Biosensia Ltd, Nova UCD, UCD, Dublin 4, Ireland
关键词
fluorescence; CCD; immunochromatographic; cocaine; human sweat; point-of-care testing; WHOLE-BLOOD; IMMUNOASSAY; ASSAY; METABOLITES; BIOSENSOR; APTAMER; PROTEIN; URINE; DRUGS; SWEAT;
D O I
10.1088/0957-0233/26/8/085401
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL(-1) limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.
引用
收藏
页数:15
相关论文
共 35 条
[1]   Development of a point-of-care assay system for high-sensitivity C-reactive protein in whole blood [J].
Ahn, JS ;
Choi, S ;
Jang, SH ;
Chang, HJ ;
Kim, JH ;
Nahm, KB ;
Oh, SW ;
Choi, EY .
CLINICA CHIMICA ACTA, 2003, 332 (1-2) :51-59
[2]   Capillary electrophoresis for forensic drug analysis: A review [J].
Anastos, N ;
Barnett, NW ;
Lewis, SW .
TALANTA, 2005, 67 (02) :269-279
[3]   From Lateral Flow Devices to a Novel Nano-Color Microfluidic Assay [J].
Assadollahi, Saied ;
Reininger, Christiane ;
Palkovits, Roland ;
Pointl, Peter ;
Schalkhammer, Thomas .
SENSORS, 2009, 9 (08) :6084-6100
[4]  
Bender Arnold E., 1995, Body Surface Area: A Dictionary of Food and Nutrition
[5]   A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I) [J].
Choi, S ;
Choi, EY ;
Kim, DJ ;
Kim, JH ;
Kim, TS ;
Oh, SW .
CLINICA CHIMICA ACTA, 2004, 339 (1-2) :147-156
[6]  
DECRESCE RP, 1989, DRUG TESTING WORKPLA
[7]   Recent trends in antibody based sensors [J].
Holford, Timothy R. J. ;
Davis, Frank ;
Higson, Seamus P. J. .
BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) :12-24
[8]   Aptamer in Bioanalytical Applications [J].
Iliuk, Anton B. ;
Hu, Lianghai ;
Tao, W. Andy .
ANALYTICAL CHEMISTRY, 2011, 83 (12) :4440-4452
[9]   Disposition of cocaine and its metabolites in human sweat after controlled cocaine administration [J].
Kacinko, SL ;
Barnes, AJ ;
Schwilke, EW ;
Cone, EJ ;
Moolchan, ET ;
Huestis, MA .
CLINICAL CHEMISTRY, 2005, 51 (11) :2085-2094
[10]   A fluorescent immunochromatographic test using immunoliposomes for detecting microcystins and nodularins [J].
Khreich, Nathalie ;
Lamourette, Patricia ;
Lagoutte, Bernard ;
Ronco, Cyril ;
Franck, Xavier ;
Creminon, Christophe ;
Volland, Herve .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) :1733-1742