A comparison of mandibular denture base deformation with different impression techniques for implant overdentures

被引:13
作者
Elsyad, Moustafa Abdou [1 ]
El-Waseef, Fatma Ahmad [1 ]
Al-Mahdy, Yasmeen Fathy [2 ]
Fouad, Mohammed Mohammed [1 ]
机构
[1] Mansoura Univ, Fac Dent, Eldakahlia, Egypt
[2] Al Azhar Univ, Fac Med Dent, Cairo, Egypt
关键词
deformation; denture base; implant; impression; overdenture; RETAINED OVERDENTURES; STRESS; STRAIN; REINFORCEMENT; MAXILLARY; FRACTURE; TISSUE; MUCOSA;
D O I
10.1111/j.1600-0501.2011.02395.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate mandibular denture base deformation along with three impression techniques used for implant-retained overdenture. Materials and methods: Ten edentulous patients (five men and five women) received two implants in the canine region of the mandible and three duplicate mandibular overdentures which were constructed with mucostatic, selective pressure, and definitive pressure impression techniques. Ball abutments and respective gold matrices were used to connect the overdentures to the implants. Six linear strain gauges were bonded to the lingual polished surface of each duplicate overdenture at midline and implant areas to measure strain during maximal clenching and gum chewing. Results: The strains recorded at midline were compressive while strains at implant areas were tensile. Clenching recorded significant higher strain when compared with gum chewing for all techniques. The mucostatic technique recorded the highest strain and the definite pressure technique recorded the lowest. There was no significant difference between the strain recorded with mucostatic technique and that registered with selective pressure technique. The highest strain was recorded at the level of ball abutment's top with the mucostatic technique during clenching. Conclusion and recommendation: Definite pressure impression technique for implant-retained mandibular overdenture is associated with minimal denture deformation during function when compared with mucostatic and selective pressure techniques. Reinforcement of the denture base over the implants may be recommended to increase resistance of fracture when mucostatic or selective pressure impression technique is used.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 44 条
  • [21] Two-step pick-up impression procedure for implant-retained overdentures
    Gregory-Head, B
    LaBarre, E
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (05) : 615 - 616
  • [22] Heart C. M., 1980, TXB COMPLETE DENTURE, V190, P199
  • [23] Ichikawa T, 1996, INT J PROSTHODONT, V9, P394
  • [24] Klemetti Esa, 2003, J Can Dent Assoc, V69, P29
  • [25] Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture
    Kubo, Kei
    Kawata, Tetsuo
    Suenaga, Hanako
    Yoda, Nobuhiro
    Shigemitsu, Ryuji
    Ogawa, Toru
    Sasaki, Keiichi
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2009, 53 (01) : 15 - 21
  • [26] KYDD WL, 1971, INT DENT J, V21, P430
  • [27] THE BIOLOGIC AND MECHANICAL EFFECTS OF STRESS ON ORAL-MUCOSA
    KYDD, WL
    DALY, CH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1982, 47 (03) : 317 - 329
  • [28] EFFECT OF MECHANICAL STRESS ON ORAL MUCOPERIOSTEUM OF DOGS
    KYDD, WL
    STROUD, W
    MOFFETT, BC
    TAMARIN, A
    [J]. ARCHIVES OF ORAL BIOLOGY, 1969, 14 (08) : 921 - &
  • [29] LeVan M. M., 1952, J PROSTHET DENT, V2, P26
  • [30] Mericske-Stern RD, 2000, CLIN ORAL IMPLAN RES, V11, P108