The impact of radiopharmaceutical particle size on the visualization and identification of sentinel nodes in breast cancer

被引:31
作者
Leidenius, MH
Leppänen, EA
Krogerus, LA
von Smitten, KA
机构
[1] Univ Helsinki Hosp, Maria Hosp, Breast Surg Unit, FIN-00180 Helsinki, Finland
[2] Univ Helsinki Hosp, Maria Hosp, Dept Nucl Med, FIN-00180 Helsinki, Finland
[3] Univ Helsinki Hosp, Maria Hosp, Dept Pathol, FIN-00180 Helsinki, Finland
关键词
breast cancer; lymphoscintigraphy; lymph node metastases; radiopharmaceutical; sentinel node biopsy;
D O I
10.1097/00006231-200403000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to compare the success rate in lymphatic mapping and sentinel node biopsy in breast cancer using two radiopharmaceuticals. Methods The study included 119 breast cancer patients who underwent lymphoscintigraphy after a single intratumoral injection of Tc-99m-labelled human albumin colloid with a particle size of 0.2-3 mum (Albu-Res) (large particle group) and 119 pair-matched control patients who underwent lymphoscintigraphy using Tc-99m-labelled albumin colloid with a particle size of <80 nm (Nanocoll) (small particle group). The dose of the tracer was used as the matching factor. Results Lymphoscintigraphy showed sentinel nodes in the axilla in 101 patients (85%) in the large particle group and in 104 patients (87%) in the small particle group. The mean number of visualized nodes in the axilla was 1.7 in the small particle group and 1.3 in the large particle group (P < 0.05). No radioactive nodes were found in the axilla during the operation in 22 patients (18%) in the small particle group and 11 patients (9%) in the large particle group (P < 0.06). Patients who avoided axillary clearance had a similar number of harvested radioactive nodes irrespective of the particle size of the tracer. Conclusions It can be concluded that the success rate in the identification of axillary sentinel nodes may be higher when using the smaller particles, despite the similar visualization rate in lymphoscintigraphy. The number of harvested radioactive nodes was not affected by the particle size of the tracer in patients who avoided axillary clearance.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 21 条
[1]   Sentinel lymph node biopsy in breast cancer: Guidelines and pitfalls of lymphoscintigraphy and gamma probe detection [J].
Borgstein, P ;
Pijpers, R ;
Comans, EF ;
van Diest, PJ ;
Boom, RP ;
Meijer, S .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (03) :275-283
[2]  
De Cicco C, 1998, J NUCL MED, V39, P2080
[3]  
Haigh PI, 2000, J NUCL MED, V41, P1682
[4]   Impact of the axillary nodal status on sentinel node mapping in breast cancer and its relevance for technical proceeding [J].
Heuser, T ;
Rink, T ;
Weller, E ;
Fitz, H ;
Zippel, HH ;
Kreienberg, R ;
Kühn, T .
BREAST CANCER RESEARCH AND TREATMENT, 2001, 67 (02) :125-132
[5]   Non-visualization of sentinel lymph node in patients with breast cancer [J].
Krausz, Y ;
Ikeda, DM ;
Jadvar, H ;
Langleben, D ;
Birdwell, R ;
Strauss, HW .
NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) :25-32
[6]   The role of dynamic imaging in sentinel lymph node biopsy in breast cancer [J].
Lee, AC ;
Keshtgar, MRS ;
Waddington, WA ;
Ell, PJ .
EUROPEAN JOURNAL OF CANCER, 2002, 38 (06) :784-787
[7]   The effect of patient and tumour characteristics on visualization of sentinel nodes after a single intratumoural injection of Tc 99m labelled human albumin colloid in breast cancer [J].
Leppänen, E ;
Leidenius, M ;
Krogerus, L ;
von Smitten, K .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2002, 28 (08) :821-826
[8]   Highest isotope count does not predict sentinel node positivity in all breast cancer patients [J].
Martin, RCG ;
Fey, J ;
Yeung, H ;
Borgen, PI ;
Cody, HS .
ANNALS OF SURGICAL ONCOLOGY, 2001, 8 (07) :592-597
[9]   Dermal injection of radioactive colloid is superior to peritumoral injection for breast cancer sentinel lymph node biopsy: Results of a multiinstitutional study [J].
McMasters, KM ;
Wong, SL ;
Martin, RCG ;
Chao, C ;
Tuttle, TM ;
Noyes, RD ;
Carlson, DJ ;
Laidley, AL ;
McGlothin, TQ ;
Ley, PB ;
Brown, CM ;
Glaser, RL ;
Pennington, RE ;
Turk, PS ;
Simpson, D ;
Cerrito, PB ;
Edwards, MJ .
ANNALS OF SURGERY, 2001, 233 (05) :676-684
[10]   Lymphatic mapping and sentinel lymph node biopsy in breast cancer [J].
Nieweg, OE ;
Jansen, L ;
Olmos, RAV ;
Rutgers, EJT ;
Peterse, JL ;
Hoefnagel, KA ;
Kroon, BBR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (04) :S11-S16